HP Insight Server Migration Software for ProLiant User Guide
Page 132
...the device corresponding to Profile 1 Hardware Profile. 2. Select SMP Source Agent Mode, and then click Delete. 3. After Windows boots, install the ProLiant Support Pack on the source. Download the latest Windows 2000 Boot from SAN HBA driver (version 5.30a2 or later) from SAN HBA driver for ..., reboot the source server to the Emulex HBA. b. If the bad block is a BL680c G5 or a BL685c G1 and you manually installed PSP without immediately installing the latest Emulex boot from HP Support for Windows 2000. Press F8 when you must first install Service Pack 1, Service Pack 2,...
...the device corresponding to Profile 1 Hardware Profile. 2. Select SMP Source Agent Mode, and then click Delete. 3. After Windows boots, install the ProLiant Support Pack on the source. Download the latest Windows 2000 Boot from SAN HBA driver (version 5.30a2 or later) from SAN HBA driver for ..., reboot the source server to the Emulex HBA. b. If the bad block is a BL680c G5 or a BL685c G1 and you manually installed PSP without immediately installing the latest Emulex boot from HP Support for Windows 2000. Press F8 when you must first install Service Pack 1, Service Pack 2,...
HP Power Capping and Dynamic Power Capping for ProLiant servers technology brief, 1st edition
Page 8
...to each server that server's minimum and maximum power consumption. With group power capping, each with their aggregated power supply rating. Many ProLiant G5 servers are changed by the user through Insight Power Manager. This capability is available through the iLO 2 or IPM interfaces. These individual...firmware: System BIOS 2008.11.01 or later iLO 2 version 1.70 or later Onboard Administrator firmware version 2.32 or later (for HP BladeSystem enclosures) At introduction, support for the servers until they are capable of supporting Dynamic Power Capping once the appropriate BIOS and ...
...to each server that server's minimum and maximum power consumption. With group power capping, each with their aggregated power supply rating. Many ProLiant G5 servers are changed by the user through Insight Power Manager. This capability is available through the iLO 2 or IPM interfaces. These individual...firmware: System BIOS 2008.11.01 or later iLO 2 version 1.70 or later Onboard Administrator firmware version 2.32 or later (for HP BladeSystem enclosures) At introduction, support for the servers until they are capable of supporting Dynamic Power Capping once the appropriate BIOS and ...
HP Power Capping and Dynamic Power Capping for ProLiant servers technology brief, 1st edition
Page 17
Dynamic Power Capping takes this particular server configuration would reduce the required cooling and electrical provisioning for a ProLiant DL380 G5 server configured with the server power consumption at a given application load and power cap rather than the specified amount of ...administrator to determine the maximum power and cooling needed to handle all environmental and load conditions. Figure 10 shows the output from the HP Power Calculator utility for the servers. The results indicate that meets the cooling requirements associated with two Quad-Core Intel Xeon X5460 ...
Dynamic Power Capping takes this particular server configuration would reduce the required cooling and electrical provisioning for a ProLiant DL380 G5 server configured with the server power consumption at a given application load and power cap rather than the specified amount of ...administrator to determine the maximum power and cooling needed to handle all environmental and load conditions. Figure 10 shows the output from the HP Power Calculator utility for the servers. The results indicate that meets the cooling requirements associated with two Quad-Core Intel Xeon X5460 ...
HP Power Capping and Dynamic Power Capping for ProLiant servers technology brief, 1st edition
Page 18
Figure 10. HP Power Calculator results for a configured ProLiant DL380 G5 server 18
Figure 10. HP Power Calculator results for a configured ProLiant DL380 G5 server 18
HP Power Capping and Dynamic Power Capping for ProLiant servers technology brief, 1st edition
Page 19
... each server's power management system. IPM generates this level would have no impact on overall server performance but would ensure that the HP Power 19 The power management system measures power consumption two times per second and records both the peak and average power consumption. Group... Power Consumption graph for a group of eight ProLiant DL380 G5 servers The peak power consumption for the server group running a typical variable load application. Setting a power cap at this graph using ...
... each server's power management system. IPM generates this level would have no impact on overall server performance but would ensure that the HP Power 19 The power management system measures power consumption two times per second and records both the peak and average power consumption. Group... Power Consumption graph for a group of eight ProLiant DL380 G5 servers The peak power consumption for the server group running a typical variable load application. Setting a power cap at this graph using ...
HP Power Capping and Dynamic Power Capping for ProLiant servers technology brief, 1st edition
Page 20
...that can be provisioned within same 7760 watts using basic Power Capping Description Maximum possible power consumption for 8 DL380 G5 servers (based on HP Power Calculator) Maximum power consumption when capping to peak Power 3384 watts 3116 watts Savings in power capacity 268 watts.... This will have an adverse affect on limiting transient peaks. HP recommends that administrators using Dynamic Power Capping Description Traditional input power provisioning for the server group. Power provisioning for eight DL380 G5 servers when capping to support them. It is possible, especially ...
...that can be provisioned within same 7760 watts using basic Power Capping Description Maximum possible power consumption for 8 DL380 G5 servers (based on HP Power Calculator) Maximum power consumption when capping to peak Power 3384 watts 3116 watts Savings in power capacity 268 watts.... This will have an adverse affect on limiting transient peaks. HP recommends that administrators using Dynamic Power Capping Description Traditional input power provisioning for the server group. Power provisioning for eight DL380 G5 servers when capping to support them. It is possible, especially ...
HP Power Capping and Dynamic Power Capping for ProLiant servers technology brief, 1st edition
Page 21
...given cooling infrastructure while only marginally impacting the overall server performance in this particular application Table 6. For example, consider an HP BladeSystem c7000 enclosure fully configured with basic Power Capping almost doubles the number of 1900 watts. This is not a concern.... achieve additional increases in provisioning capacity by using basic Power Capping Description Power Maximum power consumption for 8 ProLiant DL580 G5 servers (based on HP Power Calculator) 3384 watts Maximum power consumption when capping to average 1900 watts Savings in power capacity 1484...
...given cooling infrastructure while only marginally impacting the overall server performance in this particular application Table 6. For example, consider an HP BladeSystem c7000 enclosure fully configured with basic Power Capping almost doubles the number of 1900 watts. This is not a concern.... achieve additional increases in provisioning capacity by using basic Power Capping Description Power Maximum power consumption for 8 ProLiant DL580 G5 servers (based on HP Power Calculator) 3384 watts Maximum power consumption when capping to average 1900 watts Savings in power capacity 1484...
Implementing Microsoft Windows Server 2008 on HP ProLiant servers
Page 6
... Windows Server 2008 should load and run on any HP server listed in "Recommended system platform" section of information. ProLiant DL360 G5 - ProLiant DL380 G5 - ProLiant DL585 G2 • ProLiant ML servers: - ProLiant ML350 G5 - ProLiant BL685c • ProLiant DL servers: - Do not use this document for these servers): • ProLiant BL servers: - ProLiant BL680c G5 - Carefully review this paper as the sole source...
... Windows Server 2008 should load and run on any HP server listed in "Recommended system platform" section of information. ProLiant DL360 G5 - ProLiant DL380 G5 - ProLiant DL585 G2 • ProLiant ML servers: - ProLiant ML350 G5 - ProLiant BL685c • ProLiant DL servers: - Do not use this document for these servers): • ProLiant BL servers: - ProLiant BL680c G5 - Carefully review this paper as the sole source...
Implementing Microsoft Windows Server 2008 on HP ProLiant servers
Page 8
... supported ProLiant server. • Software and drivers: http://h20000.www2.hp.com/bizsupport/TechSupport/ProductRoot.jsp?lang=en&cc=us&taskId=135. • Windows on ProLiant support matrix: http://h10018.www1.hp.com/wwsolutions/windows/index.html. ProLiant server platforms...ProLiant BL30p I10 10/27/05 ProLiant BL35p A03 03/01/06 ProLiant BL45p A02 03/01/06 ProLiant BL45p G2 A12 09/20/07 ProLiant BL460c* I15 08/21/07 ProLiant BL465c* A13 09/20/07 ProLiant BL480c* I14 08/21/07 ProLiant BL680c G5* I17 10/18/07 ProLiant BL685c* A08 09/20/07 ProLiant DL servers: ProLiant...
... supported ProLiant server. • Software and drivers: http://h20000.www2.hp.com/bizsupport/TechSupport/ProductRoot.jsp?lang=en&cc=us&taskId=135. • Windows on ProLiant support matrix: http://h10018.www1.hp.com/wwsolutions/windows/index.html. ProLiant server platforms...ProLiant BL30p I10 10/27/05 ProLiant BL35p A03 03/01/06 ProLiant BL45p A02 03/01/06 ProLiant BL45p G2 A12 09/20/07 ProLiant BL460c* I15 08/21/07 ProLiant BL465c* A13 09/20/07 ProLiant BL480c* I14 08/21/07 ProLiant BL680c G5* I17 10/18/07 ProLiant BL685c* A08 09/20/07 ProLiant DL servers: ProLiant...
Implementing Microsoft Windows Server 2008 on HP ProLiant servers
Page 9
...02/07 ProLiant DL580 G4 P59 08/10/07 ProLiant DL580 G5* P61 12/07/07 ProLiant DL585 A01 03/22/06 ProLiant DL585 G2* A07 11/21/07 ProLiant ML servers: ProLiant ML110 G2 ML110G2 12/08/05 ProLiant ML110 G3 ML110G3 02/13/06 ProLiant ML110 G4 ML110G4 06/05/06 ProLiant ML115 ML115G1 03.../10/07 ProLiant ML310 G4 W03...
...02/07 ProLiant DL580 G4 P59 08/10/07 ProLiant DL580 G5* P61 12/07/07 ProLiant DL585 A01 03/22/06 ProLiant DL585 G2* A07 11/21/07 ProLiant ML servers: ProLiant ML110 G2 ML110G2 12/08/05 ProLiant ML110 G3 ML110G3 02/13/06 ProLiant ML110 G4 ML110G4 06/05/06 ProLiant ML115 ML115G1 03.../10/07 ProLiant ML310 G4 W03...
Implementing Microsoft Windows Server 2008 on HP ProLiant servers
Page 10
...this server. **Supported when configured with Windows Server 2008. Throughout the summer of Windows Server 2008, the HP Insight Control Management Software portfolio for the HP ProLiant and HP BladeSystem infrastructure deploys, monitors, and manages Windows Server 2008 servers. Management software With the initial launch of... Server 2008 Server platform ProLiant ML350 G4p ROM family ROM date (minimum) D19 07/16/07 ProLiant ML350 G5* D21 08/21/07 ProLiant ML370 G4 P50 07/19/07 ProLiant ML370 G5* P57 08/21/07 ProLiant ML570 G3 P37 02/09/06 ProLiant ML570 G4 P60 08/...
...this server. **Supported when configured with Windows Server 2008. Throughout the summer of Windows Server 2008, the HP Insight Control Management Software portfolio for the HP ProLiant and HP BladeSystem infrastructure deploys, monitors, and manages Windows Server 2008 servers. Management software With the initial launch of... Server 2008 Server platform ProLiant ML350 G4p ROM family ROM date (minimum) D19 07/16/07 ProLiant ML350 G5* D21 08/21/07 ProLiant ML370 G4 P50 07/19/07 ProLiant ML370 G5* P57 08/21/07 ProLiant ML570 G3 P37 02/09/06 ProLiant ML570 G4 P60 08/...
Implementing Microsoft Windows Server 2008 on HP ProLiant servers
Page 14
...x64 9 9 99 9 9 9 9 14 Network interface controllers Table 5 lists supported ProLiant network interface controllers (NICs) supported by Windows Server 2008. HP-branded drivers are available on the Windows Server 2008 media may not be available on ProLiant Support Pack 7.95" will be used instead. in this case, the value in... the "Available on the PSP; NOTE: Drivers that are not available on the web, including support for HP ProLiant G5 LOMs and the NC370T/F and NC380T. All NIC drivers are only available on the Windows Server 2008 media. The latest version of...
...x64 9 9 99 9 9 9 9 14 Network interface controllers Table 5 lists supported ProLiant network interface controllers (NICs) supported by Windows Server 2008. HP-branded drivers are available on the Windows Server 2008 media may not be available on ProLiant Support Pack 7.95" will be used instead. in this case, the value in... the "Available on the PSP; NOTE: Drivers that are not available on the web, including support for HP ProLiant G5 LOMs and the NC370T/F and NC380T. All NIC drivers are only available on the Windows Server 2008 media. The latest version of...
Implementing Microsoft Windows Server 2008 on HP ProLiant servers
Page 24
... is not found on the Windows Server 2008 media. Workaround A fix for inclusion in the G5 NIC drivers available on the PSP Version 8.00. Issue 3 The System Management Home (SMH)... Issue 4 The NIC driver for the CP6316 NIC fails to install. Table A-2. Issue 2 HP StorageWorks Fibre Channel Array Notification Driver component shows update not required, if a supported MSA controller ...is not present......Installation will not continue." Windows Server 2008 ProLiant Support Pack (PSP) Table A-2 provides a list of read/create. Description The drivers were...
... is not found on the Windows Server 2008 media. Workaround A fix for inclusion in the G5 NIC drivers available on the PSP Version 8.00. Issue 3 The System Management Home (SMH)... Issue 4 The NIC driver for the CP6316 NIC fails to install. Table A-2. Issue 2 HP StorageWorks Fibre Channel Array Notification Driver component shows update not required, if a supported MSA controller ...is not present......Installation will not continue." Windows Server 2008 ProLiant Support Pack (PSP) Table A-2 provides a list of read/create. Description The drivers were...
Implementing Microsoft Windows Server 2008 Foundation on HP ProLiant servers
Page 6
... 2008 Foundation Server platform ProLiant DL servers: ProLiant DL120 G5 ROM family ROM date (minimum) 022 02/26/08 ProLiant DL320 G5p* W05 07/02/08 ProLiant DL320 G6 W07 04/01/09 ProLiant ML servers: ProLiant ML110 G5 015 07/22/08 ProLiant ML115 G5 018 06/03/08 ProLiant ML310 G5* W05 07/02/08 ProLiant ML310 G6* *HP SmartStart Supported servers W07...
... 2008 Foundation Server platform ProLiant DL servers: ProLiant DL120 G5 ROM family ROM date (minimum) 022 02/26/08 ProLiant DL320 G5p* W05 07/02/08 ProLiant DL320 G6 W07 04/01/09 ProLiant ML servers: ProLiant ML110 G5 015 07/22/08 ProLiant ML115 G5 018 06/03/08 ProLiant ML310 G5* W05 07/02/08 ProLiant ML310 G6* *HP SmartStart Supported servers W07...
ISS Technology Update Index
Page 3
...Customizing the iLO Text Console 6 Volume 8, Number 2 February 2009 Quick tip: Disabling AMD® processor cores in ProLiant 4 300 series G5 and G6 servers Quick tip: Efficient deployments-Sun Solaris 10 for 5 x86/x64 Systems Quick tips for powering off/on... efficiency between 1 online "double-conversion" technology and online "on HP BladeSystem 10 c7000 enclosures and their components Removing disabled servers from HP Systems Insight 8 Manager S Shut down servers gracefully with the HP ProLiant ML360 5 uninterruptible power supply solution Soft memory errors caused by natural...
...Customizing the iLO Text Console 6 Volume 8, Number 2 February 2009 Quick tip: Disabling AMD® processor cores in ProLiant 4 300 series G5 and G6 servers Quick tip: Efficient deployments-Sun Solaris 10 for 5 x86/x64 Systems Quick tips for powering off/on... efficiency between 1 online "double-conversion" technology and online "on HP BladeSystem 10 c7000 enclosures and their components Removing disabled servers from HP Systems Insight 8 Manager S Shut down servers gracefully with the HP ProLiant ML360 5 uninterruptible power supply solution Soft memory errors caused by natural...
ISS Technology Update Volume 7, Number 10
Page 5
.... C:\Program Files\putty>plink -ssh -l admin -pw password ilo2system.corp.net show system1 show system1 status=0 status_tag=COMMAND COMPLETED /system1 Targets firmware1 Properties name=ProLiant DL380 G5 number=0005PBN153 oemhp_server_name=Exchange_01 enabledstate=disabled oemhp_powerreg=auto Verbs cd version exit show map1 command. ISS Technology Update Volume 7, Number 10 Retrieve properties of the...
.... C:\Program Files\putty>plink -ssh -l admin -pw password ilo2system.corp.net show system1 show system1 status=0 status_tag=COMMAND COMPLETED /system1 Targets firmware1 Properties name=ProLiant DL380 G5 number=0005PBN153 oemhp_server_name=Exchange_01 enabledstate=disabled oemhp_powerreg=auto Verbs cd version exit show map1 command. ISS Technology Update Volume 7, Number 10 Retrieve properties of the...
ISS Technology Update Volume 8, Number 5
Page 1
.../SupportManual/c018208 with VMware ESX virtualization software 49/c01820849.pdf Technologies in HP ProLiant G6 c-Class server blades with http://h20000.www2.hp.com/bc/docs/support/SupportManual/c018525 Intel® Xeon® 90/c01852590.pdf Technologies in HP ProLiant G5 c-Class Server Blades http://h20000.www2.hp.com/bc/docs/support/SupportManual/c011360 96/c01136096.pdf...
.../SupportManual/c018208 with VMware ESX virtualization software 49/c01820849.pdf Technologies in HP ProLiant G6 c-Class server blades with http://h20000.www2.hp.com/bc/docs/support/SupportManual/c018525 Intel® Xeon® 90/c01852590.pdf Technologies in HP ProLiant G5 c-Class Server Blades http://h20000.www2.hp.com/bc/docs/support/SupportManual/c011360 96/c01136096.pdf...
ISS Technology Update Volume 8, Number 6
Page 1
.../bc/docs/support/SupportManual/c018893 04/c01889304.pdf Using the HP Plinth Kit for seismic anchoring of HP 10000 G1 series racks http://h20000.www2.hp.com/bc/docs/support/SupportManual/c002514 18/c00251418.pdf HP ProLiant DL580 G5 server technology http://h20000.www2.hp.com/bc/docs/support/SupportManual/c018910 77/c01891077.pdf Implementing Microsoft Windows...
.../bc/docs/support/SupportManual/c018893 04/c01889304.pdf Using the HP Plinth Kit for seismic anchoring of HP 10000 G1 series racks http://h20000.www2.hp.com/bc/docs/support/SupportManual/c002514 18/c00251418.pdf HP ProLiant DL580 G5 server technology http://h20000.www2.hp.com/bc/docs/support/SupportManual/c018910 77/c01891077.pdf Implementing Microsoft Windows...
ISS Technology Update Volume 8, Number 7
Page 1
... papers Title Configuring SATA and SAS in HP ProLiant SL6000 servers HP ProLiant SL6000 Scalable System technology Implementing Microsoft® Windows Server® 2008 R2 Foundation on HP ProLiant servers Implementing Microsoft® Windows Server® 2008 R2 Hyper-V™ and Microsoft Hyper-V Server 2008 R2 on HP ProLiant servers HP ProLiant DL585 G5/G6 server technology The Intel processor roadmap...
... papers Title Configuring SATA and SAS in HP ProLiant SL6000 servers HP ProLiant SL6000 Scalable System technology Implementing Microsoft® Windows Server® 2008 R2 Foundation on HP ProLiant servers Implementing Microsoft® Windows Server® 2008 R2 Hyper-V™ and Microsoft Hyper-V Server 2008 R2 on HP ProLiant servers HP ProLiant DL585 G5/G6 server technology The Intel processor roadmap...
ISS Technology Update Volume 8, Number 7
Page 3
...cd/ids/developer/asmona/eng/dc/hpc/choice/200677.htm?page=2 2nd generation HP 3Gb/s SATA solid state drive technology expands SSD functionality and performance Second generation HP 3Gb/s SATA solid state drives (SSDs) for ProLiant servers are the next step in the evolution of SSDs that made them ...Increased capacities of 60 GB and 120 GB SFF and LFF hot plug supported across most of the ML, DL, and BL G5 and G6 ProLiant servers Advances in controller technology that provide significant improvements in read and write performance In addition to these websites: Resource How to...
...cd/ids/developer/asmona/eng/dc/hpc/choice/200677.htm?page=2 2nd generation HP 3Gb/s SATA solid state drive technology expands SSD functionality and performance Second generation HP 3Gb/s SATA solid state drives (SSDs) for ProLiant servers are the next step in the evolution of SSDs that made them ...Increased capacities of 60 GB and 120 GB SFF and LFF hot plug supported across most of the ML, DL, and BL G5 and G6 ProLiant servers Advances in controller technology that provide significant improvements in read and write performance In addition to these websites: Resource How to...