Microsoft Windows Event ID and SNMP Traps Reference Guide for use with SmartStart version 8.25
Page 31
...: "%1". Rebooting the server may correct this error. Event identifier: cpqstmsg.dll - 526 (Hex)0x8435020e (Service Event) Log Severity: Warning (2) Log Message: Unsupported storage system. The ProLiant storage system %1 is terminating. This indicates a low memory condition. Event identifier: cpqstmsg.dll - 527 (Hex)0x8435020f (Service Event) Log Severity: Warning (2) Storage agents 31 The...
...: "%1". Rebooting the server may correct this error. Event identifier: cpqstmsg.dll - 526 (Hex)0x8435020e (Service Event) Log Severity: Warning (2) Log Message: Unsupported storage system. The ProLiant storage system %1 is terminating. This indicates a low memory condition. Event identifier: cpqstmsg.dll - 527 (Hex)0x8435020f (Service Event) Log Severity: Warning (2) Storage agents 31 The...
Microsoft Windows Event ID and SNMP Traps Reference Guide for use with SmartStart version 8.25
Page 77
... agents 77 This error can be caused by a corrupt registry or a low memory condition. Rebooting the server may not have rebooted after installing agents. The ProLiant storage system %1 is running. The SCSI Agent could not get the slot data for the controller. Event identifier: cpqstmsg.dll - 1284 (Hex)0x84350504 (Service Event...
... agents 77 This error can be caused by a corrupt registry or a low memory condition. Rebooting the server may not have rebooted after installing agents. The ProLiant storage system %1 is running. The SCSI Agent could not get the slot data for the controller. Event identifier: cpqstmsg.dll - 1284 (Hex)0x84350504 (Service Event...
HP USB Floppy Drive Key Installation Instructions
Page 1
...accessible regardless of the position of the device, set forth in the express warranty statements accompanying such products and services. Wait for HP products and services are bootable files in this partition. 3. Part Number 442989-001 January 2007 (First Edition) 2. The only... b. The system boots from the USB drive key partition of the device switch. HP USB Floppy Drive Key Installation Instructions Overview The USB Floppy Drive Key provides HP ProLiant server users with HP ProLiant servers running Microsoft® Windows® Server™ 2000, Microsoft® Windows ...
...accessible regardless of the position of the device, set forth in the express warranty statements accompanying such products and services. Wait for HP products and services are bootable files in this partition. 3. Part Number 442989-001 January 2007 (First Edition) 2. The only... b. The system boots from the USB drive key partition of the device switch. HP USB Floppy Drive Key Installation Instructions Overview The USB Floppy Drive Key provides HP ProLiant server users with HP ProLiant servers running Microsoft® Windows® Server™ 2000, Microsoft® Windows ...
ProLiant Essentials Foundation Pack Installation Guide
Page 1
...utilities, and launch server setup. Be sure that simplifies server setup and provides consistent server configurations. • ProLiant Support Pack (PSP) - HP ProLiant Essentials Foundation Pack Installation Guide © Copyright 2002, 2008 Hewlett-Packard Development Company, L.P. Seventeenth edition (... the Adaptec RAID Configuration Utility as constituting an additional warranty. This pack supports HP ProLiant ML and DL 300, 500, and 700 servers, HP ProLiant server blades, and the HP BladeSystem c-Class. • SmartStart - provides comprehensive fault, asset, and configuration...
...utilities, and launch server setup. Be sure that simplifies server setup and provides consistent server configurations. • ProLiant Support Pack (PSP) - HP ProLiant Essentials Foundation Pack Installation Guide © Copyright 2002, 2008 Hewlett-Packard Development Company, L.P. Seventeenth edition (... the Adaptec RAID Configuration Utility as constituting an additional warranty. This pack supports HP ProLiant ML and DL 300, 500, and 700 servers, HP ProLiant server blades, and the HP BladeSystem c-Class. • SmartStart - provides comprehensive fault, asset, and configuration...
HP BladeSystem Management Pack version 1.0 for Microsoft System Center Essentials Troubleshooting Assistant
Page 6
...Management Pack for System Center Essentials 2007 kits. Select the Administration tab. 3. If the purpose of the HP ProLiant Server Management Pack for System Center Essentials 2007 kits from the System Center Essentials operator console. Verify the imported...console environment The kits do not support installation on a remote System Center Essentials console environment. If the purpose of deletion is not alerting HP BladeSystem c-Class enclosures" on System Center Essentials 2007: 1. Click Management Packs. 4. Deleting the management packs manually The management packs can ...
...Management Pack for System Center Essentials 2007 kits. Select the Administration tab. 3. If the purpose of the HP ProLiant Server Management Pack for System Center Essentials 2007 kits from the System Center Essentials operator console. Verify the imported...console environment The kits do not support installation on a remote System Center Essentials console environment. If the purpose of deletion is not alerting HP BladeSystem c-Class enclosures" on System Center Essentials 2007: 1. Click Management Packs. 4. Deleting the management packs manually The management packs can ...
HP BladeSystem Management Pack for Microsoft System Center Essentials 2007 User Guide
Page 7
... c-Class Enclosures represented in the Diagram View • Console Tasks to launch HP Onboard Administrator, HP Enclosure Monitor Manager, and HP Integrated Lights-Out Management Processors from the System Center Essentials Console • Access to HP BladeSystem c-Class Enclosure and other HP ProLiant Essentials value-added software for hardware performance management, vulnerability assessment, and advanced lifecycle...
... c-Class Enclosures represented in the Diagram View • Console Tasks to launch HP Onboard Administrator, HP Enclosure Monitor Manager, and HP Integrated Lights-Out Management Processors from the System Center Essentials Console • Access to HP BladeSystem c-Class Enclosure and other HP ProLiant Essentials value-added software for hardware performance management, vulnerability assessment, and advanced lifecycle...
HP BladeSystem Management Pack for Microsoft System Center Essentials 2007 User Guide
Page 9
... Center Essentials 2007 console. Complete the post-installation procedures to the System Center Essentials 2007. 5. The HP BladeSystem Management Pack is not for use on systems running Microsoft® System Center Operations Manager 2007. • The HP ProLiant Server Management Pack 1.0 for System Center Essentials 2007 (x64) File name Description HPBladeSystemMPforSCE1_0x Used to...
... Center Essentials 2007 console. Complete the post-installation procedures to the System Center Essentials 2007. 5. The HP BladeSystem Management Pack is not for use on systems running Microsoft® System Center Operations Manager 2007. • The HP ProLiant Server Management Pack 1.0 for System Center Essentials 2007 (x64) File name Description HPBladeSystemMPforSCE1_0x Used to...
HP BladeSystem Management Pack for Microsoft System Center Essentials 2007 User Guide
Page 18
... Name BL480c-VS13 - Integrated Lights-Out MAC 00:16:35:3D:71:BB Address - Present Power (Watts) 9 - Fan Speed (% of Present 2 Interconnect Bays - Server Name N/A HP BladeSystem Device Bay Name Device Bay 2-ProLiant Server - System Board Spare Part 410293-001 Number - Integrated Lights-Out Name ILOUSM62500TE - Redundancy Redundant - Server Name...
... Name BL480c-VS13 - Integrated Lights-Out MAC 00:16:35:3D:71:BB Address - Present Power (Watts) 9 - Fan Speed (% of Present 2 Interconnect Bays - Server Name N/A HP BladeSystem Device Bay Name Device Bay 2-ProLiant Server - System Board Spare Part 410293-001 Number - Integrated Lights-Out Name ILOUSM62500TE - Redundancy Redundant - Server Name...
HP BladeSystem Management Pack for Microsoft System Center Essentials 2007 User Guide
Page 20
... Enclosures/Enclosure State-This view displays the state view by HP BladeSystem Enclosures. • HP BladeSystem Enclosures/Health Collection State-This view displays the state view by HP ProLiant Server Management Pack for viewing information stored in managed HP BladeSystem Enclosures. • HP BladeSystem Enclosures/Enclosure Diagram-This view displays the diagram view starting with the...
... Enclosures/Enclosure State-This view displays the state view by HP BladeSystem Enclosures. • HP BladeSystem Enclosures/Health Collection State-This view displays the state view by HP ProLiant Server Management Pack for viewing information stored in managed HP BladeSystem Enclosures. • HP BladeSystem Enclosures/Enclosure Diagram-This view displays the diagram view starting with the...
HP BladeSystem Management Pack for Microsoft System Center Essentials 2007 User Guide
Page 35
... desired bay using a standard browser interface. Log in HP BladeSystem Enclosures include an Integrated Lights-Out management processor, which enables you to remotely access the selected HP ProLiant Blade server. The HP BladeSystem Management Pack 1.0 for System Center Essentials 2007 includes... a task that collects HP Integrated Lights-Out management processor data and creates an associated browser link...
... desired bay using a standard browser interface. Log in HP BladeSystem Enclosures include an Integrated Lights-Out management processor, which enables you to remotely access the selected HP ProLiant Blade server. The HP BladeSystem Management Pack 1.0 for System Center Essentials 2007 includes... a task that collects HP Integrated Lights-Out management processor data and creates an associated browser link...
HP ProLiant Servers Troubleshooting Guide
Page 1
HP ProLiant Servers Troubleshooting Guide Part Number 375445-008 July 2009 (Eighth Edition)
HP ProLiant Servers Troubleshooting Guide Part Number 375445-008 July 2009 (Eighth Edition)
HP ProLiant Servers Troubleshooting Guide
Page 3
... 2007) ...10 375445-xx5 (June 2006) ...10 375445-xx4 (May 2006)...11 375445-xx3 (September 2005) ...11 Getting started...12 HP ProLiant 100 Series Server troubleshooting information 12 How to use this guide ...12 Pre-diagnostic steps ...13 Important safety information...13 Symptom information ...16 Prepare......29 Operating system boot problems flowchart 31 Server fault indications flowchart ...32 Hardware problems ...36 Procedures for all ProLiant servers...36 Power problems ...36 Power source problems ...36 Power supply problems ...36 UPS problems ...37 General hardware problems ...38 Contents ...
... 2007) ...10 375445-xx5 (June 2006) ...10 375445-xx4 (May 2006)...11 375445-xx3 (September 2005) ...11 Getting started...12 HP ProLiant 100 Series Server troubleshooting information 12 How to use this guide ...12 Pre-diagnostic steps ...13 Important safety information...13 Symptom information ...16 Prepare......29 Operating system boot problems flowchart 31 Server fault indications flowchart ...32 Hardware problems ...36 Procedures for all ProLiant servers...36 Power problems ...36 Power source problems ...36 Power supply problems ...36 UPS problems ...37 General hardware problems ...38 Contents ...
HP ProLiant Servers Troubleshooting Guide
Page 5
... Utility ...70 StorageWorks library and tape tools 70 HP Systems Insight Manager ...70 Management Agents...71 HP ProLiant Essentials Virtualization Management Software 71 HP ProLiant Essentials Vulnerability and Patch Management Pack 71 HP Insight Server Migration software for ProLiant 72 HP ProLiant Essentials Performance Management Pack 72 HP Insight Control Environment Suites 72 HP Insight Control Linux Edition ...73 System Management...
... Utility ...70 StorageWorks library and tape tools 70 HP Systems Insight Manager ...70 Management Agents...71 HP ProLiant Essentials Virtualization Management Software 71 HP ProLiant Essentials Vulnerability and Patch Management Pack 71 HP Insight Server Migration software for ProLiant 72 HP ProLiant Essentials Performance Management Pack 72 HP Insight Control Environment Suites 72 HP Insight Control Linux Edition ...73 System Management...
HP ProLiant Servers Troubleshooting Guide
Page 9
...26). • Added new steps to Power problems (on page 36). • Added a new section to Fan problems (on page 44): All fans in an HP ProLiant G6 server are not spinning or are not spinning at the same speed (on page 45) • Added a new section to Memory problems (on page...Error Messages (on page 90) o POST error messages and beep codes (on page 114) Revision history 375445-xx7 (November 2008) The seventh edition of the HP ProLiant Servers Troubleshooting Guide, part number 375445-xx7, included the following additions and updates: • Added new information about Server updates with an...
...26). • Added new steps to Power problems (on page 36). • Added a new section to Fan problems (on page 44): All fans in an HP ProLiant G6 server are not spinning or are not spinning at the same speed (on page 45) • Added a new section to Memory problems (on page...Error Messages (on page 90) o POST error messages and beep codes (on page 114) Revision history 375445-xx7 (November 2008) The seventh edition of the HP ProLiant Servers Troubleshooting Guide, part number 375445-xx7, included the following additions and updates: • Added new information about Server updates with an...
HP ProLiant Servers Troubleshooting Guide
Page 10
... added new POST error messages and beep codes (on page 114) 375445-xx6 (September 2007) The sixth edition of the HP ProLiant Servers Troubleshooting Guide, part number 375445-xx6, included the following additions and updates: • Added new information about preventing electrostatic...o Expanded existing information o Added new firmware update procedures for unsupported processor stepping 375445-xx5 (June 2006) The fifth edition of the HP ProLiant Servers Troubleshooting Guide, part number 375445-xx5, included the following additions: • Added three new c-Class server blade flowcharts: o ...
... added new POST error messages and beep codes (on page 114) 375445-xx6 (September 2007) The sixth edition of the HP ProLiant Servers Troubleshooting Guide, part number 375445-xx6, included the following additions and updates: • Added new information about preventing electrostatic...o Expanded existing information o Added new firmware update procedures for unsupported processor stepping 375445-xx5 (June 2006) The fifth edition of the HP ProLiant Servers Troubleshooting Guide, part number 375445-xx5, included the following additions: • Added three new c-Class server blade flowcharts: o ...
HP ProLiant Servers Troubleshooting Guide
Page 11
375445-xx4 (May 2006) The fourth edition of the HP ProLiant Servers Troubleshooting Guide, part number 375445-xx4, included the following additions: • Hot-plug SAS and SATA hard drive LED combinations (on page 19) • ... ADU error messages (on page 90) and POST error messages and beep codes (on page 114) 375445-xx3 (September 2005) The third edition of the HP ProLiant Servers Troubleshooting Guide, part number 375445-xx3, included the following changes: • Updated SCSI hard drive guidelines • Added hot-plug SCSI hard drive LED...
375445-xx4 (May 2006) The fourth edition of the HP ProLiant Servers Troubleshooting Guide, part number 375445-xx4, included the following additions: • Hot-plug SAS and SATA hard drive LED combinations (on page 19) • ... ADU error messages (on page 90) and POST error messages and beep codes (on page 114) 375445-xx3 (September 2005) The third edition of the HP ProLiant Servers Troubleshooting Guide, part number 375445-xx3, included the following changes: • Updated SCSI hard drive guidelines • Added hot-plug SCSI hard drive LED...
HP ProLiant Servers Troubleshooting Guide
Page 12
... troubleshooting (on page 85) When additional information becomes necessary, use the following descriptions: • Common problem resolution (on page 90) Getting started HP ProLiant 100 Series Server troubleshooting information For HP ProLiant 100 Series Server troubleshooting information, see the respective server user guides. Getting started 12 How to use this guide and to identify...
... troubleshooting (on page 85) When additional information becomes necessary, use the following descriptions: • Common problem resolution (on page 90) Getting started HP ProLiant 100 Series Server troubleshooting information For HP ProLiant 100 Series Server troubleshooting information, see the respective server user guides. Getting started 12 How to use this guide and to identify...
HP ProLiant Servers Troubleshooting Guide
Page 17
... Components available on page 78)." Common problem resolution 17 For detailed information on updating firmware, see "Subscriber's Choice (on the HP ProLiant Firmware Maintenance CD and the HP website (http://www.hp.com/support) • The most recent version of firmware updates. For more information, see "Firmware maintenance (on the product page. Avoid bending...
... Components available on page 78)." Common problem resolution 17 For detailed information on updating firmware, see "Subscriber's Choice (on the HP ProLiant Firmware Maintenance CD and the HP website (http://www.hp.com/support) • The most recent version of firmware updates. For more information, see "Firmware maintenance (on the product page. Avoid bending...
HP ProLiant Servers Troubleshooting Guide
Page 22
... into the other flowcharts do not provide a troubleshooting solution, follow the diagnostic steps in each flowchart: 1. o HP BladeSystem p-Class Support and Documents (http://www.hp.com/products/servers/proliant-bl/p-class/info) Diagnostic flowcharts 22 The available flowcharts include: • Start diagnosis flowchart (on page 24) ... be used when the problem is not server-specific or is a generic troubleshooting process to external websites. HP ProLiant maintenance and service guides: o Business Support Center (http://www.hp.com/go/bizsupport) Select Manuals. Under Servers, select...
... into the other flowcharts do not provide a troubleshooting solution, follow the diagnostic steps in each flowchart: 1. o HP BladeSystem p-Class Support and Documents (http://www.hp.com/products/servers/proliant-bl/p-class/info) Diagnostic flowcharts 22 The available flowcharts include: • Start diagnosis flowchart (on page 24) ... be used when the problem is not server-specific or is a generic troubleshooting process to external websites. HP ProLiant maintenance and service guides: o Business Support Center (http://www.hp.com/go/bizsupport) Select Manuals. Under Servers, select...
HP ProLiant Servers Troubleshooting Guide
Page 36
...press the switch firmly. 2. Hardware problems Procedures for all ProLiant servers The procedures in the On position. 7. Power supply problems Action: 1. For more information, see the HP Power Advisor on the HP website (http://www.hp.com/support). 3. Be sure the proper circuit breaker is ... recently added hardware, such as hard drives. Hardware problems 36 For product-specific information, see the server documentation on the HP website (http://www.hp.com/go/hppoweradvisor). For more information, see the server documentation on . Power problems Power source problems Action: 1. If the...
...press the switch firmly. 2. Hardware problems Procedures for all ProLiant servers The procedures in the On position. 7. Power supply problems Action: 1. For more information, see the HP Power Advisor on the HP website (http://www.hp.com/support). 3. Be sure the proper circuit breaker is ... recently added hardware, such as hard drives. Hardware problems 36 For product-specific information, see the server documentation on the HP website (http://www.hp.com/go/hppoweradvisor). For more information, see the server documentation on . Power problems Power source problems Action: 1. If the...