Drive technology overview
Page 8
... channel bandwidths are now double their previous rates, allowing twice as much data to be built into the mother board or provided as entry level and external storage. SATA 3.0 Gb/s is only achieved using new SAS-2 compliant disk...performance is usually considered the best solution for price-sensitive, low I/O workload server applications, such as an adaptor card. SATA is targeted to workstations and low-end servers. SATA uses a seven-pin, small-diameter cable. SATA 1.5 Gb/s with extensions 3.0 Gb/s The initial SATA 1.5 Gb/s variant was introduced with HP ProLiant G6 servers...
... channel bandwidths are now double their previous rates, allowing twice as much data to be built into the mother board or provided as entry level and external storage. SATA 3.0 Gb/s is only achieved using new SAS-2 compliant disk...performance is usually considered the best solution for price-sensitive, low I/O workload server applications, such as an adaptor card. SATA is targeted to workstations and low-end servers. SATA uses a seven-pin, small-diameter cable. SATA 1.5 Gb/s with extensions 3.0 Gb/s The initial SATA 1.5 Gb/s variant was introduced with HP ProLiant G6 servers...
HP ProLiant Servers Troubleshooting Guide
Page 48
...8226; If a channel contains quad-rank DIMMs, the quad-rank DIMM must be installed first on the system board: CAUTION: Do not operate the server for long periods with HP iLO 2 Firmware version 1.75, the IML message reports the following message: Memory Configuration Error: System boot ...check the processor LEDs to identify if a PPM failure occurred. Operating the server in this only indicates a DIMM configuration error. PPM problems Action: If the PPMs are installed for the server and is an HP ProLiant G6 server with HP iLO 2 Firmware version 1.77 or later, the IML message reports the ...
...8226; If a channel contains quad-rank DIMMs, the quad-rank DIMM must be installed first on the system board: CAUTION: Do not operate the server for long periods with HP iLO 2 Firmware version 1.75, the IML message reports the following message: Memory Configuration Error: System boot ...check the processor LEDs to identify if a PPM failure occurred. Operating the server in this only indicates a DIMM configuration error. PPM problems Action: If the PPMs are installed for the server and is an HP ProLiant G6 server with HP iLO 2 Firmware version 1.77 or later, the IML message reports the ...
Technology and architecture of HP ProLiant Intel-based 300-series G6 (Generation 6) servers
Page 8
...memory channel must be empty. Since each mirrored DIMM is supported only on select ProLiant 300-series G6 servers allows the PC3-10600R memory modules to obtain the correct data. Only HP branded DIMMS have produced system boards with a Xeon X5500 (95W) or W5500 (130W) processor. If an ...is still protected by a DIMM failure, the other DIMM in ProLiant G6 servers, use the DDR-3 Memory Configuration Tool found at 95W or 130W. As a result, even after mirroring is replaced and the server rebooted. Therefore, HP does not recommend configuring the BIOS setting for 1333 MT/s ...
...memory channel must be empty. Since each mirrored DIMM is supported only on select ProLiant 300-series G6 servers allows the PC3-10600R memory modules to obtain the correct data. Only HP branded DIMMS have produced system boards with a Xeon X5500 (95W) or W5500 (130W) processor. If an ...is still protected by a DIMM failure, the other DIMM in ProLiant G6 servers, use the DDR-3 Memory Configuration Tool found at 95W or 130W. As a result, even after mirroring is replaced and the server rebooted. Therefore, HP does not recommend configuring the BIOS setting for 1333 MT/s ...