HP Insight Server Migration Software for ProLiant User Guide
Page 132
... appears, select Last Known Good Configuration (your destination server is a BL680c G5 or a BL685c G1 and you must first install Service Pack 1, Service Pack 2, and the updated Storport storage driver (see the following message: Please select the operating system to a server ...when Windows boots up , uninstall the "HP Storageworks Tape Drivers for Windows" drivers. Press F8 when you manually installed PSP without immediately installing the latest Emulex boot from SAN HBA driver for Windows 2000. After Windows boots, install the ProLiant Support Pack on the destination server. Right...
... appears, select Last Known Good Configuration (your destination server is a BL680c G5 or a BL685c G1 and you must first install Service Pack 1, Service Pack 2, and the updated Storport storage driver (see the following message: Please select the operating system to a server ...when Windows boots up , uninstall the "HP Storageworks Tape Drivers for Windows" drivers. Press F8 when you manually installed PSP without immediately installing the latest Emulex boot from SAN HBA driver for Windows 2000. After Windows boots, install the ProLiant Support Pack on the destination server. Right...
Implementing Microsoft Windows Server 2008 on HP ProLiant servers
Page 8
...ProLiant BL30p I10 10/27/05 ProLiant BL35p A03 03/01/06 ProLiant BL45p A02 03/01/06 ProLiant BL45p G2 A12 09/20/07 ProLiant BL460c* I15 08/21/07 ProLiant BL465c* A13 09/20/07 ProLiant BL480c* I14 08/21/07 ProLiant BL680c G5* I17 10/18/07 ProLiant BL685c* A08 09/20/07 ProLiant DL servers: ProLiant...version and family of the supported ProLiant server. • Software and drivers: http://h20000.www2.hp.com/bizsupport/TechSupport/ProductRoot.jsp?lang=en&cc=us&taskId=135. • Windows on ProLiant support matrix: http://h10018.www1.hp.com/wwsolutions/windows/index.html....
...ProLiant BL30p I10 10/27/05 ProLiant BL35p A03 03/01/06 ProLiant BL45p A02 03/01/06 ProLiant BL45p G2 A12 09/20/07 ProLiant BL460c* I15 08/21/07 ProLiant BL465c* A13 09/20/07 ProLiant BL480c* I14 08/21/07 ProLiant BL680c G5* I17 10/18/07 ProLiant BL685c* A08 09/20/07 ProLiant DL servers: ProLiant...version and family of the supported ProLiant server. • Software and drivers: http://h20000.www2.hp.com/bizsupport/TechSupport/ProductRoot.jsp?lang=en&cc=us&taskId=135. • Windows on ProLiant support matrix: http://h10018.www1.hp.com/wwsolutions/windows/index.html....
Implementing Microsoft Windows Server 2008 on HP ProLiant servers
Page 10
...Microsoft Windows Server 2008 Version 8.00 is enabled for ProLiant servers Software drivers HP recommends administrators utilize the drivers on the Windows Server 2008 operating system. Also the HP Rapid Deployment Pack (RDP) can be managed by HP Systems Insight Manager (HP SIM) if the management agents are not supported. ... Windows Server 2008 Server platform ProLiant ML350 G4p ROM family ROM date (minimum) D19 07/16/07 ProLiant ML350 G5* D21 08/21/07 ProLiant ML370 G4 P50 07/19/07 ProLiant ML370 G5* P57 08/21/07 ProLiant ML570 G3 P37 02/09/06 ProLiant ML570 G4 P60 08/02...
...Microsoft Windows Server 2008 Version 8.00 is enabled for ProLiant servers Software drivers HP recommends administrators utilize the drivers on the Windows Server 2008 operating system. Also the HP Rapid Deployment Pack (RDP) can be managed by HP Systems Insight Manager (HP SIM) if the management agents are not supported. ... Windows Server 2008 Server platform ProLiant ML350 G4p ROM family ROM date (minimum) D19 07/16/07 ProLiant ML350 G5* D21 08/21/07 ProLiant ML370 G4 P50 07/19/07 ProLiant ML370 G5* P57 08/21/07 ProLiant ML570 G3 P37 02/09/06 ProLiant ML570 G4 P60 08/02...
Implementing Microsoft Windows Server 2008 on HP ProLiant servers
Page 14
... 2008 media may not be available on the software and drivers website: http://h20000.www2.hp.com/bizsupport/TechSupport/ProductRoot.jsp?lang=en&cc=us&taskId=135. Supported ProLiant Gigabit Ethernet NICs Gigabit NIC Driver Location NC1020 NC150T NC320m NC320T NC325m NC326m NC110T NC310 NC310F... 9 NOTE: Many of each Options ROMPaq is available on the PSP; All NIC drivers are on the PSP and have firmware upgrades available through variations of the Options ROMPaq. Drivers for HP ProLiant G5 LOMs and the NC370T/F and NC380T. The latest version of these devices have a ...
... 2008 media may not be available on the software and drivers website: http://h20000.www2.hp.com/bizsupport/TechSupport/ProductRoot.jsp?lang=en&cc=us&taskId=135. Supported ProLiant Gigabit Ethernet NICs Gigabit NIC Driver Location NC1020 NC150T NC320m NC320T NC325m NC326m NC110T NC310 NC310F... 9 NOTE: Many of each Options ROMPaq is available on the PSP; All NIC drivers are on the PSP and have firmware upgrades available through variations of the Options ROMPaq. Drivers for HP ProLiant G5 LOMs and the NC370T/F and NC380T. The latest version of these devices have a ...
Implementing Microsoft Windows Server 2008 on HP ProLiant servers
Page 24
... install. 24 Windows Server 2008 ProLiant Support Pack (PSP) Table A-2 provides a list of the known issues with the PSP Issue Details Issue 1 The G5 NIC drivers are not found behind a Fibre Channel HBA. Issue 4 The NIC driver for a future release of read/create. Issue 2 HP StorageWorks Fibre Channel Array Notification Driver component shows update not required...
... install. 24 Windows Server 2008 ProLiant Support Pack (PSP) Table A-2 provides a list of the known issues with the PSP Issue Details Issue 1 The G5 NIC drivers are not found behind a Fibre Channel HBA. Issue 4 The NIC driver for a future release of read/create. Issue 2 HP StorageWorks Fibre Channel Array Notification Driver component shows update not required...
Implementing Microsoft Windows Server 2008 Foundation on HP ProLiant servers
Page 6
... ProLiant DL servers: ProLiant DL120 G5 ROM family ROM date (minimum) 022 02/26/08 ProLiant DL320 G5p* W05 07/02/08 ProLiant DL320 G6 W07 04/01/09 ProLiant ML servers: ProLiant ML110 G5 015 07/22/08 ProLiant ML115 G5 018 06/03/08 ProLiant ML310 G5* W05 07/02/08 ProLiant ML310 G6* *HP ...contents to the hard disk during installation. • Refer to contain the system files. http://h71028.www7.hp.com/enterprise/cache/458915-0-0-0-121.html • Software and drivers: - Additional space is installed. NOTE • Available disk space refers to the free disk space on...
... ProLiant DL servers: ProLiant DL120 G5 ROM family ROM date (minimum) 022 02/26/08 ProLiant DL320 G5p* W05 07/02/08 ProLiant DL320 G6 W07 04/01/09 ProLiant ML servers: ProLiant ML110 G5 015 07/22/08 ProLiant ML115 G5 018 06/03/08 ProLiant ML310 G5* W05 07/02/08 ProLiant ML310 G6* *HP ...contents to the hard disk during installation. • Refer to contain the system files. http://h71028.www7.hp.com/enterprise/cache/458915-0-0-0-121.html • Software and drivers: - Additional space is installed. NOTE • Available disk space refers to the free disk space on...
ISS Technology Update, Volume 7 Number 1 - Newsletter
Page 11
...by iLO. The error is logged to run . Table 5-2. OS with health driver (thermal shutdown enabled) The error is handled by iLO. The shutdown is logged in the IML by iLO in -first-out record of ProLiant DL and ML servers with redundant fans Scenario Behavior* Single fan fails during ...POST The error is logged in the IML by the health driver if it is logged in the event of models with redundant fans ProLiant DL and ML servers with G5 Intel processor-based systems and G2 AMD processor-based systems, graceful shutdowns can be maintained. The...
...by iLO. The error is logged to run . Table 5-2. OS with health driver (thermal shutdown enabled) The error is handled by iLO. The shutdown is logged in the IML by iLO in -first-out record of ProLiant DL and ML servers with redundant fans Scenario Behavior* Single fan fails during ...POST The error is logged in the IML by the health driver if it is logged in the event of models with redundant fans ProLiant DL and ML servers with G5 Intel processor-based systems and G2 AMD processor-based systems, graceful shutdowns can be maintained. The...
Technologies for HP ProLiant 100-series G5 (Generation 5) servers, 2nd edition
Page 9
... brief titled "RAID 6 with dedicated memory and processor. Hardware RAID is achieved through the option ROM and device driver. HP Embedded SATA RAID supports Microsoft® Windows®, Linux® and NetWare operating systems. Server deployment Deployment is ... the user to add a physical disk to a specific environment. RAID 6 (double parity) is available on the ProLiant ML115 G5 server. HP ProLiant Easy Set-up CD The ProLiant ML110 G5 and ML115 G5 servers include an Easy Set-up a server. RAID 5 is available when using the BBWC.8 Some server configurations include...
... brief titled "RAID 6 with dedicated memory and processor. Hardware RAID is achieved through the option ROM and device driver. HP Embedded SATA RAID supports Microsoft® Windows®, Linux® and NetWare operating systems. Server deployment Deployment is ... the user to add a physical disk to a specific environment. RAID 6 (double parity) is available on the ProLiant ML115 G5 server. HP ProLiant Easy Set-up CD The ProLiant ML110 G5 and ML115 G5 servers include an Easy Set-up a server. RAID 5 is available when using the BBWC.8 Some server configurations include...
Technologies for HP ProLiant 100-series G5 (Generation 5) servers, 2nd edition
Page 10
The Easy Set-up CD is tailored to a specific server model (ML110 G5 or ML115 G5) and loads operating system drivers that provides remote server access and control capabilities through the process of ProLiant servers. In the Assisted mode, the Easy Set-up CD guides the user through an Ethernet... interface. Available as part of an HP Care Pack service option, RDP ...
The Easy Set-up CD is tailored to a specific server model (ML110 G5 or ML115 G5) and loads operating system drivers that provides remote server access and control capabilities through the process of ProLiant servers. In the Assisted mode, the Easy Set-up CD guides the user through an Ethernet... interface. Available as part of an HP Care Pack service option, RDP ...
Sun Solaris 10 Deployment Guide for HP ProLiant Servers
Page 39
... one or more PCI devices have the device driver support for the SATA Controller in RAID mode. • Workaround-Solaris does not support this controller in IDE mode. HP ProLiant BL260c G5, BL280c G6 • Description-Cannot install SUN Solaris 10 operating system on an HP ProLiant BL260c G5 or BL280c G6 blade server when the SATA controller is...
... one or more PCI devices have the device driver support for the SATA Controller in RAID mode. • Workaround-Solaris does not support this controller in IDE mode. HP ProLiant BL260c G5, BL280c G6 • Description-Cannot install SUN Solaris 10 operating system on an HP ProLiant BL260c G5 or BL280c G6 blade server when the SATA controller is...
Sun Solaris 10 Deployment Guide for HP ProLiant Servers
Page 41
... gigabit Ethernet NIC fails to attach. • OS releases affected-Solaris 10 8/07, 5/08, 10/08 • Servers affected-HP ProLiant BL685c, BL685c G5, BL680c, BL480c, BL260c G5 • Description-The Broadcom NetXtreme Gigabit Ethernet Driver (BRCMbcme) v10.4.5 or later successfully installs but fails to attach" message is seen during the installation of Broadcom NetXtreme...
... gigabit Ethernet NIC fails to attach. • OS releases affected-Solaris 10 8/07, 5/08, 10/08 • Servers affected-HP ProLiant BL685c, BL685c G5, BL680c, BL480c, BL260c G5 • Description-The Broadcom NetXtreme Gigabit Ethernet Driver (BRCMbcme) v10.4.5 or later successfully installs but fails to attach" message is seen during the installation of Broadcom NetXtreme...