HP Basic Power Distribution Unit Installation Guide - Page 4
...not overload the PDU. Before you begin
Overview
This document provides installation instructions for qualified personnel for Server, Storage, Power, Networking, and Rack Products, available at the HP website (http://www.hp.com/support/Safety-Compliance-EnterpriseProducts). Important safety information
Before installation, read the Important Safety Information that the load products connected to...
HP Monitored Power Distribution Unit User Guide - Page 6
... Firmware and Web Pages 99 Upgrading the HP Firmware with FTP Protocol 100 Uploading the Binary File 100 Upgrade the Firmware and Web Pages 101 Active Alarms 101 Defining the Alarm or Event Condition 102 Type Code 0 or 1 (OS or System 103 Type 2 or 3 (PDU or User 104
10 SPECIFICATIONS 108 Model List 108 Weights and Dimensions 109 Electrical Input...
HP Monitored Power Distribution Unit User Guide - Page 7
..., depending on the model.
Figure 1 shows an example of outlets vary by model. HP Monitored PDU Installed (Bottom Entry Method)
HP Monitored PDU User's Guide P-164000281-Rev 1
...HP (LS26) outlets. The HP Monitored PDUs are designed to be installed in HP 10000 series racks or Intelligent series racks, but can be used in a rack. HP Monitored PDUs are 1Ph (single-phase) and 3Ph (three-phase...
HP Monitored Power Distribution Unit User Guide - Page 8
... for standard racks. The PDU models support 1Ph or 3Ph applications and provide between 12 and 36 outlets.
All models feature an LCD window, a set of a 1U form factor PDU model. Circuit breakers are two DV (dual voltage) models. Figure 2. 1U Example Model (D9N43A 1Ph Model)
HP Monitored PDU User's Guide P-164000281-Rev 1
2 Introduction
HP Monitored PDU Models
The Enterprise PDUs are...
HP Monitored Power Distribution Unit User Guide - Page 13
... used for future reference.
SAVE THESE INSTRUCTIONS
This manual contains important instructions that you should be installed near water or excessive humidity (90% maximum noncondensing). DANGER
This PDU contains LETHAL VOLTAGES. All repairs and service should follow during installation and operation of fire or electric shock, install this manual for the power supply to this product...
HP Monitored Power Distribution Unit User Guide - Page 19
... in a rack and the rack is being shipped. Installation
Models D9N45A and D9N46A have an IEC 60320 C20 power input receptacle for attaching a C19 to the rack post.
42U PDU
22U or 36U PDU
Figure 6. These cables are supplied with sensors can be installed using the manufacturer's instruction manual.
!
When the PDU is unpacked, retain the...
HP Monitored Power Distribution Unit User Guide - Page 26
Refer to the manufacturer's installation manual for instructions to connect the external contact inputs to it.
! Connecting the EMP to secure the Ethernet cable out of the way as needed. You can be installed without turning off power to the PDU or the devices connected to the optional EMP for the EMP equipment. IMPORTANT
Follow all...
HP Monitored Power Distribution Unit User Guide - Page 35
...Service...settings. The LCD also provides some basic configuration. For more information, see "Menu and Status Display" on page 30...phase. NOTE To manually disconnect power to on a computer with three phase...input connector plug with three phase wires, a protective earth (ground) wire, and no neutral wire. Pin Positions
The pin arrays are different for most models.
HP Monitored PDU User's Guide...
HP Monitored Power Distribution Unit User Guide - Page 37
... activated manually. The user cannot select a custom sequence of the display for the PDU. The backlight is not user-configurable.To selectively view values, navigate through the LCD. l Settings mode (LCD main menu) The settings that display current PDU values. However, this set of up-to conserves energy.The screen darkens. HP Monitored PDU User's Guide...
HP Monitored Power Distribution Unit User Guide - Page 38
...Backward (Down) Scroll Button
6
Escape (ESC) Button
7
Enter Key
8
Forward (Up) Scroll Button
HP Monitored PDU User's Guide P-164000281-Rev 1
32 Communication and Environmental Monitoring Ports
Reference Number
Description
1
Service or Serial Port (Settings/Sensor)
2
Yellow Serial Service Port LED: RS-232 Operation and Activity Status
OFF: Normal operation
FLASHING: Communicating...
HP Monitored Power Distribution Unit User Guide - Page 42
... after 30 seconds of inactivity from the start-up , the Startup screen displays (see Figure 28).
Values are reset every five seconds.The screensaver displays data in a preset 1Ph cycle (Figure 26) or 3Ph cycle (Figure 27).
5 s
hp
IP Address Part Number
Total Input
14.8
Amp
5 s
Figure 26. 1Ph Screensaver Cycle
5 s
hp
5 s
IP Address Part Number
Phase...
HP Monitored Power Distribution Unit User Guide - Page 44
...3Ph wye-wired PDUs. Figure 30. HP Monitored PDU Menu Hierarchy
HP Monitored PDU User's Guide P-164000281-Rev 1
38 NOTE 5 These submenus are available on sections that measure current.
LCD Interface Operation
HP
AACCTITVIVEE ALAALRAMRSMS
ALARMS HISTORY
AlaArlmarm1 t1otNo N
Alarm 1 to N
PDU
METER SECTIONS
NOTE 1
ENVIRONMENT
Input Phases
Total Input
NOTE 3 NOTE 4
Voltage
Current...
HP Monitored Power Distribution Unit User Guide - Page 56
...supports Microsoft Internet Explorer 8.0 and greater, Firefox (installed on the PDU model... default password is ...model description, part number, serial number and the current PDU firmware...HP Monitored PDU User's Guide P-164000281-Rev 1
50
Click Login to continue or Cancel to retrieve PDU performance data, review operation log information, or retrieve system or network configuration settings...
HP Monitored Power Distribution Unit User Guide - Page 116
... 3-wire
20
4
-
- D9N51A
3P
L15-30
18
3
-
-
D9N62A
3P
60309 32A/30A 5-wire
12
12
-
-
D9N57A
3P
60309 16A 5-wire
30
3
-
- D9N58A
3P
CS8365C 50A 4-...HP Monitored PDU User's Guide P-164000281-Rev 1
110 D9N52A
3P
L21-20
18
-
3
-
Electrical Input and Output (By Model) (Continued)
Model
Phases
Plug/Inlet
C13 Outlets
C19 Outlets
5-20R Outlets
RF-203P-HP...
HP Monitored Power Distribution Unit User Guide - Page 120
... Pack (service upgrade), see the HP website (http:// pro-aq-sama.houston.hp.com/services/cache/10950-0-0-225-121.html). HP Product QuickSpecs For more information on the HP Product Bulletin website (http://www.hp.com/go /ilo/docs). l Technical support registration number (if applicable)
l Product serial number
l Product model name and number
l Product identification number
l Applicable error...
HP 8.6kVA 208 Volt L15-30 3-Phase Input 18xC13/3xC19 Reviews
Do you have an experience with the HP 8.6kVA 208 Volt L15-30 3-Phase Input 18xC13/3xC19 that you would like to share?
Earn 750 points for your review!
We have not received any reviews for HP yet.
Earn 750 points for your review!