Haier AU36NAIBEA Support and Manuals
Get Help and Manuals for this Haier item
This item is in your list!
View All Support Options Below
Free Haier AU36NAIBEA manuals!
Problems with Haier AU36NAIBEA?
Ask a Question
Free Haier AU36NAIBEA manuals!
Problems with Haier AU36NAIBEA?
Ask a Question
Popular Haier AU36NAIBEA Manual Pages
User Manual - Page 1
Please keep this manual carefully. ROOM AIR CONDITIONER
OUTDOOR UNIT INSTALLATION INSTRUCTIONS
AU142AFBEA
CONTENTS
Name of Parts 1 Safety Cautions 2-3 Installation Procedure---------4-13
AU182AFBEA
AU242AHBEA AU282AHBEA AU28NAHBEA
AU36NAIBEA AU42NAIBEA AU52NAIBEA
No.0010572472 H
Before using the air conditioner,please read this manual properly for future use.
User Manual - Page 3
... air-conditioner ... user, this manual should be checked for any abnormal phenomena is very dangerous whichmay harm human beings. If the conditioner is not repaired, the unit may...repairment may cause electrical shock or fire hazard. INSTRUCTIONS: These information can be at any time when needed.
Below are listed three kinds of the outdoor unit. When need maintenance and repairment...
User Manual - Page 4
... air-conditioner with inflammable gases because the inflammable gases near to prevent the refrigerant from leaking.
Safety Cautions
WARNING! Installed electrical...conditioner is deinstalled or reinstalleddealer should not be respon- May not use wire or any other materials replacing fuse, other-wise may cause accidents.
When conditioner is installed in a small room be installed...
User Manual - Page 5
... neighborhood. Place where there is needed for the unit. Fix the parts with screws
(2).Don't intake the strong wind directly to place where short-circuit is a possibility. Installation Procedure
Installation of electric wires from an opening edge. Edging
2. Mount guide-louvers to the outlet air-flow hole.
(3).A one meter distance should be discharged. Place where...
User Manual - Page 6
... less than 3 degrees.
(2) Installation sketch of outdoor unit
AU142AFBEA
780
Power Wiring Terminal
640 25
Power Wiring Distribution Hole
5 AU142AFBEA AU182AFBEA AU242AHBEA AU282AHBEA AU28NAHBEA
(a) Concrete foundation
(b) Foundation anchor
Unit Unit Anchor bolt
Concrete foundation
To fix by bolts
Concrete foundation Anchor bolt
AU36NAIBEA AU42NAIBEA AU52NAIBEA
(a) Concrete foundation...
User Manual - Page 7
Installation Procedure
Installation of outdoor unit
270
500
AU182AFBEA
810
Power Wiring Terminal
Power Wiring Distribution Hole
680
580
315
288
AU242AHBEA AU282AHBEA AU28NAHBEA
948
Power Wiring Terminal
Power Wiring Distribution Hole
580
380 840
25
340
6
User Manual - Page 8
Refrigerant piping
(1) Outline piping
Flare connection
Gas pipe
3-way stop valve
Indoor unit
Liquid pipe Flare connection
Outdoor unit
AU242AHBEA AU282AHBEA AU28NAHBEA
3-way stop valve
Flare connection Gas pipe
Indoor unit
Liquid pipe
3-way stop valve
Outdoor unit
3-way stop valve
AU142AFBEA AU182AFBEA AU36NAIBEA AU42NAIBEA AU52NAIBEA
7 Installation Procedure
Installation of ...
User Manual - Page 9
...let foreign matters, such as possible. Model
One way piping length
AU142AFBEA AU182AFBEA AU242AHBEA AU282AHBEA AU28NAHBEA
AU36NAIBEA AU42NAIBEA AU52NAIBEA
less than 40 m ...sure that no dust is mixed in piping. Installation Procedure
Refrigerant piping
(2) Piping size
AU142AFBEA
AU182AFBEA
AU242AHBEA AU282AHBEA AU28NAHBEA
AU36NAIBEA AU42NAIBEA AU52NAIBEA
Liquid pipe Gas pipe Liquid pipe Gas...
User Manual - Page 10
Installation Procedure
Refrigerant piping
5. Low pressure peizometer
Indoor
Outdoor
High pressure peizometer
3-way valve totally closed
(Gas side)
VL VH
Meter separator
Completely tightened
Flare part
Discharging valve
Completely tightened
Indoor units
Flare part... PRESSURE GAUGE
SWEAT JOINT
LARGE SLIP-ON CONNECTOR
SERVICE HOUSE
CYLINDER PRESSURE GAUGE
CYLINDER OF NITROGEN
Check ...
User Manual - Page 11
...AU282AHBEA, AU28NAHBEA, AU36NAIBEA,
AU42NAIBEA, AU52NAIBEA M=65
Only in the system. When vacuumizing, it shall charge Mg additional refrigerant per meter. If changes, it is any leaking point and repair the them. ...the VL and VH on the length of low pressure vavle. Installation Procedure
Refrigerant piping
6. After air tightness test and discharging all the nitrogen, connect the vacuum ...
User Manual - Page 12
...Installation Procedure
Electric wiring
5.
Do not connect more than 2% voltage drop.)
Item
Circuit breaker
Power source Earth leakage breaker
Model
Phase Switch breaker Overcurrent protector wire size Switch Leak
(A)
rated capacity (A) (minimum) breaker current
AU28NAHBEA 3
30
AU36NAIBEA...corresponding indoor operation and instruction manual. Electric wiring
WARNING
DANGER ...
User Manual - Page 13
....3.INCORRECT WIRING CAUSE EQUIPMENT DAMAGE.
(3) Wiring procedure
1) Remove set screws on the side before taking off the front panel toward... side panel.
12 Installation Procedure
For :AU242AHBEA, AU282AHBEA
To Indoor Unit
Y/G
L N
W B Y/G
POWER SUPPLY: 1PH,220-230V~,50Hz
Y/G
12 3
W B R Y/G
OUTDOOR UNIT TERMINAL BLOCK
FIG.2
Electric wiring
For:AU28NAHBEA, AU36NAIBEA, AU42NAIBEA, AU52NAIBEA
To...
User Manual - Page 14
...AU36NAIBEA, AU42NAIBEA, AU52NAIBEA)
(2) Test run
CAUTION
THIS UNIT WILL BE STARTED INSTANTLY WITHOUT "ON" OPERATION WHEN ELECTRIC POWER IS SUPPLIED.BE SURE TO EXECUTE "OFF" OPERATION BEFORE ELECTRIC POWER IS DISCONNECTED FOR SERVICING. sensor abnormal Indoor coil temp.
sensor abnormal
Code...exterior annunciator Coil gas pipe temp. Trouble display
Failure description
Room temp. ...
Haier AU36NAIBEA Reviews
Do you have an experience with the Haier AU36NAIBEA that you would like to share?
Earn 750 points for your review!
We have not received any reviews for Haier yet.
Earn 750 points for your review!