Maintenance Manual
Page 18
... for maintenance 7-2 7.1.2 Maintenance requirements 7-3 7.1.3 Maintenance levels 7-5 7.1.4 Disk drive revision number 7-6 7.1.5 Tools and test equipment 7-8 7.1.6 Self-diagnostics 7-8 7.1.7 Test...7-8 7.2 Operation Confirmation 7-11 7.2.1 Operation test 7-11 7.2.2 Diagnostic test 7-11 7.3 Troubleshooting Procedure 7-12 7.3.1 Troubleshooting procedure 7-12 7.3.2 Troubleshooting disk drive replaced in field 7-12 7.3.3 Troubleshooting at factory 7-14 7.4 Disk Drive Removal Procedure 7-15 7.5 Spare Disk Drive 7-15 Glossary ...GL-1 Acronyms and Abbreviations AB...
... for maintenance 7-2 7.1.2 Maintenance requirements 7-3 7.1.3 Maintenance levels 7-5 7.1.4 Disk drive revision number 7-6 7.1.5 Tools and test equipment 7-8 7.1.6 Self-diagnostics 7-8 7.1.7 Test...7-8 7.2 Operation Confirmation 7-11 7.2.1 Operation test 7-11 7.2.2 Diagnostic test 7-11 7.3 Troubleshooting Procedure 7-12 7.3.1 Troubleshooting procedure 7-12 7.3.2 Troubleshooting disk drive replaced in field 7-12 7.3.3 Troubleshooting at factory 7-14 7.4 Disk Drive Removal Procedure 7-15 7.5 Spare Disk Drive 7-15 Glossary ...GL-1 Acronyms and Abbreviations AB...
Maintenance Manual
Page 20
... power-on (when the device is powered on earlier than the host 6-3 Response to COMRESET 6-4 Response to a software reset 6-7 Data buffer structure 6-13 Figure 7.1 Disk drive revision number label 7-6 Figure 7.2 Display of disk drive revision number 7-7 Figure 7.3 Test flowchart 7-9 xvi C141-E293
... power-on (when the device is powered on earlier than the host 6-3 Response to COMRESET 6-4 Response to a software reset 6-7 Data buffer structure 6-13 Figure 7.1 Disk drive revision number label 7-6 Figure 7.2 Display of disk drive revision number 7-7 Figure 7.3 Test flowchart 7-9 xvi C141-E293
Maintenance Manual
Page 21
... value data 5-59 Format of guarantee failure threshold value data 5-59 Off-line data collection status 5-62 Self-test execution status 5-62 Off-line data collection capability 5-63 Failure prediction capability flag 5-63 Drive error logging capability 5-64 Log Directory Data Format 5-64 Data format of SMART Summary Error Log 5-65 Data...
... value data 5-59 Format of guarantee failure threshold value data 5-59 Off-line data collection status 5-62 Self-test execution status 5-62 Off-line data collection capability 5-63 Failure prediction capability flag 5-63 Drive error logging capability 5-64 Log Directory Data Format 5-64 Data format of SMART Summary Error Log 5-65 Data...
Maintenance Manual
Page 62
... Power-on Sequence Figure 4.3 describes the operation sequence of the disk drive at power-on , the disk drive initializes its SATA interface block. c) The disk drive executes self-diagnosis (data buffer read /write test. d) After confirming that the spindle motor has reached rated speed, the... head assembly is described below. f) The drive becomes ready. g) The disk drive executes self -calibration. This collects data...
... Power-on Sequence Figure 4.3 describes the operation sequence of the disk drive at power-on , the disk drive initializes its SATA interface block. c) The disk drive executes self-diagnosis (data buffer read /write test. d) After confirming that the spindle motor has reached rated speed, the... head assembly is described below. f) The drive becomes ready. g) The disk drive executes self -calibration. This collects data...
Maintenance Manual
Page 63
MPU bus test - c) Self-diagnosis 2 - Work RAM write/read test - Internal register write/read test The spindle motor starts. Data buffer write/read test d) Confirming spindle motor speed Load the head assembly e) Initial on-track and read out of system information f) Drive ready state (command waiting state) g) Execute self-calibration End Figure 4.3 Power-on Start a) SATA I/F Initialization b) Self-diagnosis 1 - 4.4 Power-on Sequence Power-on operation sequence C141-E293 4-7
MPU bus test - c) Self-diagnosis 2 - Work RAM write/read test - Internal register write/read test The spindle motor starts. Data buffer write/read test d) Confirming spindle motor speed Load the head assembly e) Initial on-track and read out of system information f) Drive ready state (command waiting state) g) Execute self-calibration End Figure 4.3 Power-on Start a) SATA I/F Initialization b) Self-diagnosis 1 - 4.4 Power-on Sequence Power-on operation sequence C141-E293 4-7
Maintenance Manual
Page 115
... xx FR xx At command completion (Shadow Block Registers contents to the host. 5.3 Host Commands (7) EXECUTE DEVICE DIAGNOSTIC (X '90') This command performs an internal diagnostic test (self-diagnosis) of power-on diagnostic test. • Error reporting conditions (1) A SATA communication error occurred (ST = 51h, ER = 14h).
... xx FR xx At command completion (Shadow Block Registers contents to the host. 5.3 Host Commands (7) EXECUTE DEVICE DIAGNOSTIC (X '90') This command performs an internal diagnostic test (self-diagnosis) of power-on diagnostic test. • Error reporting conditions (1) A SATA communication error occurred (ST = 51h, ER = 14h).
Maintenance Manual
Page 129
... turned on or off -line data then transfers the RegDH when collection of the attribute value information, see Table 5.11. In this drive, this subcommand, if saves device attribute value data, and transfers the RegDH, then reports the status. In the captive mode, it ...device which receives this command starts collecting the off -line mode) 7Fh: Self-test stop 81h: Simple self-test (captive mode) 82h: Comprehensive self-test (captive mode) 83h: Conveyance self-test (captive mode) 84h: Selective self-test (captive mode) C141-E293 5-55 SMART ENABLE/DISABLE ATTRIBUTE AUTOSAVE: Enables (by...
... turned on or off -line data then transfers the RegDH when collection of the attribute value information, see Table 5.11. In this drive, this subcommand, if saves device attribute value data, and transfers the RegDH, then reports the status. In the captive mode, it ...device which receives this command starts collecting the off -line mode) 7Fh: Self-test stop 81h: Simple self-test (captive mode) 82h: Comprehensive self-test (captive mode) 83h: Conveyance self-test (captive mode) 84h: Selective self-test (captive mode) C141-E293 5-55 SMART ENABLE/DISABLE ATTRIBUTE AUTOSAVE: Enables (by...
Maintenance Manual
Page 130
...: 01h: 33h: 01h: 01h: 01h-10h: 01h: Log sector SMART log directory SMART summary error log SMART comprehensive error log SMART self-test log SMART selective self-test log Host vendor log SCT Status Request SCT Read Data X 'D6' * See Table 5.18 concerning the SMART error log data format. See..., it enables SMART, then transfers the RegDH. 5-56 C141-E293 See Table 5.21 concerning the SMART selective self-test log data format. See Table 5.20 concerning the SMART self-test log data format. Next, it receives data from the host computer, it has prepared to 5.30 concerning the SCT...
...: 01h: 33h: 01h: 01h: 01h-10h: 01h: Log sector SMART log directory SMART summary error log SMART comprehensive error log SMART self-test log SMART selective self-test log Host vendor log SCT Status Request SCT Read Data X 'D6' * See Table 5.18 concerning the SMART error log data format. See..., it enables SMART, then transfers the RegDH. 5-56 C141-E293 See Table 5.21 concerning the SMART selective self-test log data format. See Table 5.20 concerning the SMART self-test log data format. Next, it receives data from the host computer, it has prepared to 5.30 concerning the SCT...
Maintenance Manual
Page 133
... time [min.] Comprehensive self-test (Comprehensive Test) execution time [min.] Reserved Vendor unique Check sum Table 5.11 Format of guarantee failure threshold value data Byte(hex) 00, 01 02 03 04 to ... 2 to (The format of each threshold value is the same as Threshold 30 that of bytes 02 to 0D.) Off-line data collection status Self-test execution status Off-line data collection execution time [sec.] Reserved Off-line data collection capability Trouble prediction capability flag Error logging capability (Self...
... time [min.] Comprehensive self-test (Comprehensive Test) execution time [min.] Reserved Vendor unique Check sum Table 5.11 Format of guarantee failure threshold value data Byte(hex) 00, 01 02 03 04 to ... 2 to (The format of each threshold value is the same as Threshold 30 that of bytes 02 to 0D.) Off-line data collection status Self-test execution status Off-line data collection execution time [sec.] Reserved Off-line data collection capability Trouble prediction capability flag Error logging capability (Self...
Maintenance Manual
Page 135
...If this bit 1, it indicates the attribute that represents an error rate. If the attribute value is larger than the threshold value, the drive is determined to be collected/saved even if SMART is retained. • Off-line data collection status C141-E293 5-61 The host compares ...5.3 Host Commands • Status Flag Bit 0 1 2 3 4 5 6 to 15 Meaning If this bit is 1 (0), it indicates the attribute only updated by an online test (off-line test). If this bit is 1, it indicates the attribute that can be normal. • Attribute value for the Ultra ATA CRC error rate and communication...
...If this bit 1, it indicates the attribute that represents an error rate. If the attribute value is larger than the threshold value, the drive is determined to be collected/saved even if SMART is retained. • Off-line data collection status C141-E293 5-61 The host compares ...5.3 Host Commands • Status Flag Bit 0 1 2 3 4 5 6 to 15 Meaning If this bit is 1 (0), it indicates the attribute only updated by an online test (off-line test). If this bit is 1, it indicates the attribute that can be normal. • Attribute value for the Ultra ATA CRC error rate and communication...
Maintenance Manual
Page 136
... before completion because of unknown contents. Off-line data collection is indicated as a percentage in progress. 5-62 C141-E293 Self-test has ended with "Servo Check," error. Interface Table 5.12 Off-line data collection status Status Byte Meaning 00h or 80h 02h... %). Self-test has ended with "SMART Drive Error Log Check," "Random Read Test," "Adjacent G-List Test, " or "Read Scan Test" error. Off-line data collection has ended without an error. Self-test execution status Self-test has ended successfully, or self-test has not been executed. Self-test is not ...
... before completion because of unknown contents. Off-line data collection is indicated as a percentage in progress. 5-62 C141-E293 Self-test has ended with "Servo Check," error. Interface Table 5.12 Off-line data collection status Status Byte Meaning 00h or 80h 02h... %). Self-test has ended with "SMART Drive Error Log Check," "Random Read Test," "Adjacent G-List Test, " or "Read Scan Test" error. Off-line data collection has ended without an error. Self-test execution status Self-test has ended successfully, or self-test has not been executed. Self-test is not ...
Maintenance Manual
Page 137
... offline data collection capability is 1, it indicates that off -line data collection carried out by the drive. test is supported. 6 If this bit is 1, it indicates that the SMART Selective Self-test is supported. 7 Reserved bits • Failure prediction capability flag Table 5.15 Failure prediction capability flag... that the attribute value is not supported. 5.3 Host Commands • Off-line data collection capability Indicates the method of the drive. If this bit is 1, it indicates that the attribute value is saved automatically after the pre-set operation of off -line...
... offline data collection capability is 1, it indicates that off -line data collection carried out by the drive. test is supported. 6 If this bit is 1, it indicates that the SMART Selective Self-test is supported. 7 Reserved bits • Failure prediction capability flag Table 5.15 Failure prediction capability flag... that the attribute value is not supported. 5.3 Host Commands • Off-line data collection capability Indicates the method of the drive. If this bit is 1, it indicates that the attribute value is saved automatically after the pre-set operation of off -line...
Maintenance Manual
Page 141
... D4h) and cause the device to the disk medium. C141-E293 5-67 5.3 Host Commands • Status Bits 0 to 3: Indicates the drive status when received error commands according to 1FE Reserved Reserved 1FF Check sum Check sum "n" indicates sector number in the Error Log. When the ...self-test is 0. • SMART Self-Test The host computer can read the SMART self-test log. Bits 4 to 7: Vendor unique Status 0 1 2 3 4 5 to F Meaning Unclear status Sleep status Standby status...
... D4h) and cause the device to the disk medium. C141-E293 5-67 5.3 Host Commands • Status Bits 0 to 3: Indicates the drive status when received error commands according to 1FE Reserved Reserved 1FF Check sum Check sum "n" indicates sector number in the Error Log. When the ...self-test is 0. • SMART Self-Test The host computer can read the SMART self-test log. Bits 4 to 7: Vendor unique Status 0 1 2 3 4 5 to F Meaning Unclear status Sleep status Standby status...
Maintenance Manual
Page 142
...to 0A 0B to 19 1A to 19.) Vendor unique Self-test index Reserved Check sum • Self-test number Indicates the type of self-test executed. • Self-test execution status Same as byte 16Bh of the attribute value. • Self-test index If this is the same as that in byte 02 ...to 1F9 1FA, 1FB 1FC 1FD, 1FE 1FF Item Self-test log data structure Self-test log 1 Self-test number (Sector Number field Value) Self-test execution status Life time. Total power-on time [hours] Self-test error No. Error LBA Vendor unique Self-test log 2 to 21 (Each log data format is "00h", ...
...to 0A 0B to 19 1A to 19.) Vendor unique Self-test index Reserved Check sum • Self-test number Indicates the type of self-test executed. • Self-test execution status Same as byte 16Bh of the attribute value. • Self-test index If this is the same as that in byte 02 ...to 1F9 1FA, 1FB 1FC 1FD, 1FE 1FF Item Self-test log data structure Self-test log 1 Self-test number (Sector Number field Value) Self-test execution status Life time. Total power-on time [hours] Self-test error No. Error LBA Vendor unique Self-test log 2 to 21 (Each log data format is "00h", ...
Maintenance Manual
Page 143
... Flags Offline Execution Flag Vender Unique Selective Offline Scan Number Reserved Selective Self-test pending time [min] Checksum • Test Span Selective self-test log provides for a test span are both zero, a test span is not defined and not tested. • Current LBA under test As the self-test progress, the device shall modify this value to five...
... Flags Offline Execution Flag Vender Unique Selective Offline Scan Number Reserved Selective Self-test pending time [min] Checksum • Test Span Selective self-test log provides for a test span are both zero, a test span is not defined and not tested. • Current LBA under test As the self-test progress, the device shall modify this value to five...
Maintenance Manual
Page 144
... active. Reserved Bit [l] shall be written as zeros by the host and the device shall modify them as the test progress. • Selective Self-test pending time [min] The selective self-test pending time is the time in 48-CMD environment. 5-70 C141-E293 Moreover, WRITE LOG EXT/READ LOG EXT is... used in minutes from power-on to the resumption of the off -line scan after selective test is pending. When set to one, off -line scan after selective test. Bit [3:4] shall be written by the host and returned unmodified by the device. Interface • Current Span under...
... active. Reserved Bit [l] shall be written as zeros by the host and the device shall modify them as the test progress. • Selective Self-test pending time [min] The selective self-test pending time is the time in 48-CMD environment. 5-70 C141-E293 Moreover, WRITE LOG EXT/READ LOG EXT is... used in minutes from power-on to the resumption of the off -line scan after selective test is pending. When set to one, off -line scan after selective test. Bit [3:4] shall be written by the host and returned unmodified by the device. Interface • Current Span under...
Maintenance Manual
Page 161
..."WORD63". Bit 15: Reserved Bit 14: 1 = Write Read Verify feature set supported Bit 13: 1 = SMART Conveyance self-test supported Bit 12: 1 = SMART Selective self-test supported Bit 11: 1 = FUA (Forced Unit Access) supported Bit 10: Reserved Bit 9: 1 = Streaming feature set supported ...up in Standby feature set supported Bit 3: 1 = Security feature set supported Bit 2: 1 = SMART error log supported Bit 1: 1 = SMART self-test supported Bit 0: 1 = SMART feature set supported Reflected in IDENTIFY information "WORD60-61". (WORD100-103) * Command set/feature set supported C141-E293 ...
..."WORD63". Bit 15: Reserved Bit 14: 1 = Write Read Verify feature set supported Bit 13: 1 = SMART Conveyance self-test supported Bit 12: 1 = SMART Selective self-test supported Bit 11: 1 = FUA (Forced Unit Access) supported Bit 10: Reserved Bit 9: 1 = Streaming feature set supported ...up in Standby feature set supported Bit 3: 1 = Security feature set supported Bit 2: 1 = SMART error log supported Bit 1: 1 = SMART self-test supported Bit 0: 1 = SMART feature set supported Reflected in IDENTIFY information "WORD60-61". (WORD100-103) * Command set/feature set supported C141-E293 ...
Maintenance Manual
Page 187
...: Bit 10: Bit 9: Undefined. '1' = Supports the NOP command. '1' = Supports the READ BUFFER command. '1' = Supports the WRITE BUFFER command. Bits 4-2: Reserved Bit 1: '1' = Supports the SMART SELF-TEST. Bit 13: '1' = Support the Unload Immediate command. Bit 4: Bit 3: Bit 2: Bit 1: Bit 0: 5.3 Host Commands '1' = Supports the Removable Media Status Notification feature set. '1' = Supports the Advanced...
...: Bit 10: Bit 9: Undefined. '1' = Supports the NOP command. '1' = Supports the READ BUFFER command. '1' = Supports the WRITE BUFFER command. Bits 4-2: Reserved Bit 1: '1' = Supports the SMART SELF-TEST. Bit 13: '1' = Support the Unload Immediate command. Bit 4: Bit 3: Bit 2: Bit 1: Bit 0: 5.3 Host Commands '1' = Supports the Removable Media Status Notification feature set. '1' = Supports the Advanced...
Maintenance Manual
Page 222
Versatile log data includes the Extended SMART Comprehensive Error log, the Extended SMART Self-test log, and the SMART Selective log. The effectiveness of sectors to be transferred) is specified as the Sector count. The number of the log to ...
Versatile log data includes the Extended SMART Comprehensive Error log, the Extended SMART Self-test log, and the SMART Selective log. The effectiveness of sectors to be transferred) is specified as the Sector count. The number of the log to ...
Maintenance Manual
Page 234
... be returned for all subsequent ATA commands (ST = 71h, ER = 04h). Versatile log data includes the Extended SMART Comprehensive Error log, the Extended SMART Self-test log, and the SMART Selective log;
... be returned for all subsequent ATA commands (ST = 71h, ER = 04h). Versatile log data includes the Extended SMART Comprehensive Error log, the Extended SMART Self-test log, and the SMART Selective log;