User Manual - Page 1
Specifications are trademarks of their respective companies. All product names are subject to change without notice. All rights reserved. Ti100, Ti105, Ti110, Ti125, TiR105, TiR110, TiR125
Thermal Imagers
Users Manual
PN 3889825 February 2012, Rev.1, 2/13 © 2012-2013 Fluke Corporation.
User Manual - Page 7
... software is a general-purpose Imager. Infrared images display in many applications. The Imager includes SmartView® software. Introduction
The Fluke Ti100, Ti105, Ti110, Ti125, TiR105, TiR110, and TiR125 Thermal Imagers (the Product or Imager) are handheld, infrared imaging cameras for use the IR-OptiFlex™ focus system. These applications include equipment troubleshooting...
User Manual - Page 11
... Product contains a lithium-ion battery.
Thermal Imagers Accessories
Table 1 is classed as unsorted municipal waste. Audio indicator
Symbol
Description
Connected to relevant South Korean EMC standards.
The affixed label indicates that you must not discard this electrical/electronic product in this manual. Go to Fluke's website for recycling information. p j Pause...
User Manual - Page 13
... or capacities.
[2] To request a printed manual of a language not supplied with the Imager. Specify the product name and language preference in Table 3. Fluke does not warrant the use )
Users Manuals in print (English, Spanish, French, German, Chinese)[2]
Users Manuals on CD[2]
SmartView® Software
Warranty Registration Card
[1] Fluke recommends the SD memory card...
User Manual - Page 18
... moves out of the Imager. Ti100, Ti105, Ti110, Ti125, TiR105, TiR110, TiR125 Users Manual
To operate the IR-OptiFlex...manual mode or to fine tune the focus, turn the focus control, you will also feel a detent at this mode, in addition to correctly focused infrared images, the IR-Fusion must always be in a clockwise or counterclockwise direction. You will see a live thermal image...
User Manual - Page 20
... Ti100, Ti105, Ti110, Ti125, TiR105, TiR110, TiR125 Users Manual
How...Imager information. The text above each function button applies to that the object is in focus. Push / to Use the Menus
The menus, coupled with the three function buttons and arrow buttons, are the access for thermal image display, camera features, memory review, and settings for Measurement, Image, Camera...
User Manual - Page 24
...Imager senses the infrared energy from the surface of energy radiated is ≥90 % (or 0.90). This simplification does not work on the actual surface temperature and the surface emissivity of Ti100, Ti105, Ti110, Ti125, TiR105, TiR110, TiR125 Users Manual
Temperature Measurement
All objects radiate infrared... to calculate an estimated temperature value. The quantity of the object ...
User Manual - Page 26
... a higher temperature level. 2. See Figure 4. Push to move the range to toggle between Auto Range and Manual Range. Ti100, Ti105, Ti110, Ti125, TiR105, TiR110, TiR125 Users Manual
Fast Auto/Manual Range Toggle When NOT in the thermal field of view. This feature operates the Imager in the same Range mode, Auto or Manual, as needed. To set the level: 1.
User Manual - Page 27
... temperature span:
1. Level
Thermal Imagers Menus
Total Imager Range Span
Figure 4. In the live manual mode, the arrow buttons ...manual span, the scale along the right side of the display shows the thermal span increasing or decreasing in a temperature range within the total range. Level and Span Settings
gju02.eps
Temperature Span for Manual Operation Mode
When in manual mode, the span setting...
User Manual - Page 36
... or to understand infrared images through the use of an aligned visible image and infrared image.
Full Visible mode is also available. (The Fluke Ti100 does not have IR-Fusion and can only display a full infrared image.)
Table 7. IR-Fusion®
IR-Fusion® makes it to 15 ft). Push . 2. Ti100, Ti105, Ti110, Ti125, TiR105, TiR110, TiR125 Users Manual
10.
User Manual - Page 37
... apparent temperature color alarms (not applicable for Ti100, Ti105, TiR105). Push / to highlight the option: Set High Alarm.
2.
Note The Imager does not sense ambient or surface dew point level automatically. To use the low-temperature color alarm function as a dew point color alarm, manual determination and input of both high and low...
User Manual - Page 44
... to use. 2. Ti100, Ti105, Ti110, Ti125, TiR105, TiR110, TiR125 Users Manual
CNX™ Wireless System
The Imager supports the Fluke CNX™ Wireless System (may not be available in all regions). See the documentation of available tools found within the 20 m distance.
10. Push / to exit the CNX setup menu. If these settings are acceptable, push...
User Manual - Page 50
... back to the previous menu. • to cancel the change and go back to the live view.
44
Imager Information
You can access information about the Imager from the Settings Menu. Push . 2. Push or to highlight Settings. 3. Ti100, Ti105, Ti110, Ti125, TiR105, TiR110, TiR125 Users Manual
8. Push or to the live view.
User Manual - Page 53
... C22.2 No. 61010-1-04, UL STD 61010-1 (2nd Edition) ISA 82.02.01
47 Thermal Imagers General Specifications
User-selectable File Format (all models: .IS2, .JPG, .BMP / varies by model: .IS3, .AVI) Cardinal Compass (all models except Ti100, Ti105, TiR105) Laser Pointer (on the image User-selectable Sleep/Auto Off Color Alarms
High Temperature Ti110, Ti125, TiR125 Low Temperature (Dewpoint Ti125...
User Manual - Page 54
... ° x 22.5 ° Spatial Resolution (IFOV 3.39 mRad
Minimum Focus Distance
Ti100, Ti105, TiR105 122 cm (approx. 48 in)
Ti110, Ti125, TiR110, TiR125 15 cm (approx. 6 in)
48 Ti100, Ti105, Ti110, Ti125, TiR105, TiR110, TiR125 Users Manual
Electromagnetic Compatibility (EMI, RFI, EMC, RF Meets all models
Imaging Performance
Field of it. Vibration 2 G, IEC 68-2-26 Shock 25 G, IEC...
Fluke Ti105 Reviews
Do you have an experience with the Fluke Ti105 that you would like to share?
Earn 750 points for your review!
We have not received any reviews for Fluke yet.
Earn 750 points for your review!