User Manual - Page 1
All product names are subject to change without notice. Printed in USA. ®
1587/1577 Insulation Multimeters
Users Manual
PN 2401027 April 2005 Rev. 2, 6/09
© 2005-2009 Fluke Corporation. Specifications are trademarks of their respective companies. All rights reserved.
User Manual - Page 2
... difficulty, postage and insurance prepaid (FOB Destination). Warranty support is available only if product is submitted for repair in accordance with its functional specifications for the repair and return transportation charges (FOB Shipping Point).
To obtain warranty service, contact your nearest Fluke authorized service center to obtain return authorization information, then send the...
User Manual - Page 3
... (Sleep Mode 4 Rotary Switch Positions 5 Buttons ...6 Understanding the Display 8 Input Terminals...11 Power-Up Options ...12 AutoHold Mode...13 MIN MAX AVG Recording Mode 13 Manual Ranging and Autoranging 14 Understanding AC Zero Input Behavior of True RMS Meters 15 Low-Pass Filter (Model 1587 and 1587T 15
i
User Manual - Page 4
... or DC Current 22 Testing Insulation ...24 Measuring Frequency (Model 1587 and 1587T 25
Cleaning...27 Testing the Batteries ...27 Testing the Fuse ...27 Replacing the Batteries and Fuse 28 Specifications...29
General Specifications 29 Electrical Specifications 30
AC Voltage Measurement 30 1587 and 1587T Accuracy 30 1587 and 1587T Low-Pass Filter Voltage 31 1577 Accuracy...31...
User Manual - Page 11
...Fixed equipment installations at the distribution level; 1587/1577
Insulation Multimeters
Introduction
The Fluke Models 1587,1587T, and 1577 are designed to IV) based on the magnitude of danger from the primary supply level (overhead or underground utility service).
Although this manual describes the operation of all models, all illustrations and examples assume use of Model 1587. CAT IV...
User Manual - Page 12
... the rated voltage as specified in
doubt, have the Meter serviced. • Always use the Meter or test leads if they appear damaged, or if the Meter is not operating properly. These voltages pose a shock
hazard.
2 To register your product, visit http://register.fluke.com.
1587/1577 Users Manual
Or, visit Fluke's website at www...
User Manual - Page 14
... a voltage overload (OL), the Z symbol is momentarily displayed when you move the rotary switch to or from the c position.
This is turned.
1587/1577 Users Manual
Accessories
Model
Leads
Probes
Clips
1587 and 1587T TL224
TP74
AC285
1577
TL224
TL74
AC285
Unsafe Voltage
To alert you to the presence of Sleep mode when a key...
User Manual - Page 16
...Buttons
Use the buttons to activate smoothing during insulation testing (1587 only). Buttons
bav03f.eps
6 Ohms from 0.01 mA... 100, 250, 500 (default), and 1000 V source on the 1587 or 500 (default) and 1000 V source on the 1577 or 50...1587 and 1587T only)
c
a
INSULATION
Measurement Function
Continuity test. Performs insulation test with the rotary switch. The last selected high voltage setting...
User Manual - Page 20
... not operate at all until the battery is present.
10
Table 5. Appears when insulation test voltage is replaced. Appears on the primary display and indicates that the battery is replaced.
Insulation test indicator. 1587/1577 Users Manual
Table 4. Display Indicators (cont.)
Feature Auto Range ManualRange 610000mV
2500V 1000V
T
Description Display range in or out...
User Manual - Page 22
...12
Table 7. 1587/1577 Users Manual
. The display shows S - - - q input terminal for voltage, continuity, resistance, diode, capacitance, voltage frequency, and temperature (Model 1587 and 1587T only... C switch position displays the software
version number. E switch position displays the model
number. The remaining positions show all LCD segments. Smoothing dampens display fluctuations of...
User Manual - Page 25
...measurement accuracy over the specified measurement ranges. They do not use the Low-Pass Filter function to Manual mode.
Low Pass Filter
bav16f.eps
15 Note
When using the Low-Pass filter function, the... generated by pressing the r button. Low-Pass Filter (Model 1587 and 1587T)
The 1587 is indicated may fluctuate due to detect the possible presence of hazardous voltage.
User Manual - Page 30
The beeper allows you to perform quick continuity tests without having to watch the display. To test for Continuity
The continuity test features a beeper that sounds as long as shown in Figure 10.The beeper sounds when a short ( 1587/1577 Users Manual
Testing for continuity, set up the Meter as a circuit is complete.
User Manual - Page 32
... to the circuit under test, break circuit, insert Meter in Figure 12.
22 To measure ac or dc current, set up the Meter as shown in series, turn power ON. 1587/1577 Users Manual
Measuring AC or DC Current XWWarning
To avoid personal injury or damage to the Meter: • Never attempt to...
User Manual - Page 34
... primary display until the batteries are replaced.
3. The resistance reading appears on the test points and release the t button. To measure insulation resistance set up the Meter as shown in ...started or a different function or range is selected or > 30 V is inhibited. 1587/1577 Users Manual
Testing Insulation
Insulation tests should only be measured. Check the fuse before proceeding.
5. ...
User Manual - Page 46
Insulation Specifications
Measurement Range Model 1587 0.01 MΩ to 2 GΩ Model 1577 0.1 MΩ to 600 MΩ Model 1587T 0.01 MΩ to 100 MΩ
Test Voltages Model 1587 50, 100, 250, 500, 1000 V Model 1577 500, 1000 V Model 1587T 50, 100 V
Test Voltage Accuracy 20 %, - 0 % Short-Circuit Test Current 1 mA nominal Auto Discharge Discharge time 30 V prior to initialization of...
Fluke 1587/MDT FC-NIST Reviews