FE 1520 Users Manual
Page 3
Table of Contents Title Page Unpacking the Meter 1 Safety Information and Symbols 3 Key functions ...6 Display ...8 Using the Meter 10 Connecting to the Circuit Under Test 10 Auto-Shut-Off 12 Measuring Insulation Resistance 12 Measuring Low Resistance 16 Measuring Resistance 18 Measuring Voltage 18 Checking the Battery 19 Maintaining the Meter 20 Cleaning...20 Replacing and Disposing of the Batteries 21 Testing and Replacing the Fuse 24 Replacement Parts and Optional Accessories 27 Principle of Measurement for Resistance 28 Service Centers 28 Specifications...29 i
Table of Contents Title Page Unpacking the Meter 1 Safety Information and Symbols 3 Key functions ...6 Display ...8 Using the Meter 10 Connecting to the Circuit Under Test 10 Auto-Shut-Off 12 Measuring Insulation Resistance 12 Measuring Low Resistance 16 Measuring Resistance 18 Measuring Voltage 18 Checking the Battery 19 Maintaining the Meter 20 Cleaning...20 Replacing and Disposing of the Batteries 21 Testing and Replacing the Fuse 24 Replacement Parts and Optional Accessories 27 Principle of Measurement for Resistance 28 Service Centers 28 Specifications...29 i
FE 1520 Users Manual
Page 10
... test leads. 5 Do not use the Meter if the battery indicator ( ) shows a battery empty condition. • Use only Fluke recommended batteries and fuse. • Do not use the Meter with any parts or cover removed. • Do not use the Meter around explosive gas, vapor or dust. • Disconnect the test leads...
... test leads. 5 Do not use the Meter if the battery indicator ( ) shows a battery empty condition. • Use only Fluke recommended batteries and fuse. • Do not use the Meter with any parts or cover removed. • Do not use the Meter around explosive gas, vapor or dust. • Disconnect the test leads...
FE 1520 Users Manual
Page 29
... input terminals and short them together. If the display reads >40 Ω, replace the fuse as described in the "Replacement Parts and Optional Accessories" section. To prevent personal injury or damage to test the internal fuse of the Meter. 1. acf06f.eps 24 ...Function. 2. Testing the Fuse e Use the following procedure to the Meter, install ONLY Fluke specified fuse identified in the next section. The display should indicate approximately 0.5 Ω. Press TEST. 3. Fluke 1520 Users Manual W Testing and Replacing the Fuse Warning To avoid electric shock, disconnect the ...
... input terminals and short them together. If the display reads >40 Ω, replace the fuse as described in the "Replacement Parts and Optional Accessories" section. To prevent personal injury or damage to test the internal fuse of the Meter. 1. acf06f.eps 24 ...Function. 2. Testing the Fuse e Use the following procedure to the Meter, install ONLY Fluke specified fuse identified in the next section. The display should indicate approximately 0.5 Ω. Press TEST. 3. Fluke 1520 Users Manual W Testing and Replacing the Fuse Warning To avoid electric shock, disconnect the ...
FE 1520 Users Manual
Page 32
MegOhmMeter Replacement Parts and Optional Accessories Replacement Parts and Optional Accessories Replacement Part Battery 1.5 V Alkaline Size C Test Lead set Test Probe, 1 kV, lantern tip, red Test Probe, 1 kV, lantern tip, black Alligator Clip, red Alligator Clip, black Carrying ... A Minimum Interrupt rating W OR Fuse, 6 mm x 32 mm (0.25 x 1.25 inch), 0.5 A, 750 V, Fast Acting Optional Accessories Harness WTool Pack For safety, use exact replacement only. Part Number 423582 669058 803459 803467 803434 803442 603115 670643 669069 NA 1556096...
MegOhmMeter Replacement Parts and Optional Accessories Replacement Parts and Optional Accessories Replacement Part Battery 1.5 V Alkaline Size C Test Lead set Test Probe, 1 kV, lantern tip, red Test Probe, 1 kV, lantern tip, black Alligator Clip, red Alligator Clip, black Carrying ... A Minimum Interrupt rating W OR Fuse, 6 mm x 32 mm (0.25 x 1.25 inch), 0.5 A, 750 V, Fast Acting Optional Accessories Harness WTool Pack For safety, use exact replacement only. Part Number 423582 669058 803459 803467 803434 803442 603115 670643 669069 NA 1556096...
FE 1520 Users Manual
Page 39
...support is available if product is purchased through a Fluke authorized sales outlet or Buyer has paid the applicable international price. Following warranty repair, the product will be returned to Buyer, transportation prepaid (FOB Destination). Parts, product repairs and services are warranted for damage ... to fuses, disposable batteries or to extend a greater or different warranty on the date of shipment. Fluke 1520 Users Manual Limited Warranty & Limitation of Liability Each Fluke product is warranted to be free from defects in material and workmanship under normal use outside of the...
...support is available if product is purchased through a Fluke authorized sales outlet or Buyer has paid the applicable international price. Following warranty repair, the product will be returned to Buyer, transportation prepaid (FOB Destination). Parts, product repairs and services are warranted for damage ... to fuses, disposable batteries or to extend a greater or different warranty on the date of shipment. Fluke 1520 Users Manual Limited Warranty & Limitation of Liability Each Fluke product is warranted to be free from defects in material and workmanship under normal use outside of the...