Fluke 116 Digital Multimeter Datasheet
Page 2
... 45 Hz to 5 kHz for ac current. Fluke Corporation 116 HVAC Multimeter with Temperature and Microamps Included TL75 Test Leads, 80BK Integrated Temperature Probe, holster, User's manual and 9V battery (installed).... + 2 1.9 % + 2 1.9 % + 2 5 % + 20 10 % + 2 typical 1 % + 102 1 % + 182 Ordering information Fluke-116 HVAC Multimeter with Temperature and Microamps Fluke. Auto-V LoZ, and ac mV are shorted together. Fluke Corporation PO Box 9090, Everett, WA USA 98206 Fluke Europe B.V. For volts, crest factor of reading] + [counts]) 2.0 % + 3 2.0 % + 3 (dc, 45 Hz to 500 Hz) 4.0 %...
... 45 Hz to 5 kHz for ac current. Fluke Corporation 116 HVAC Multimeter with Temperature and Microamps Included TL75 Test Leads, 80BK Integrated Temperature Probe, holster, User's manual and 9V battery (installed).... + 2 1.9 % + 2 1.9 % + 2 5 % + 20 10 % + 2 typical 1 % + 102 1 % + 182 Ordering information Fluke-116 HVAC Multimeter with Temperature and Microamps Fluke. Auto-V LoZ, and ac mV are shorted together. Fluke Corporation PO Box 9090, Everett, WA USA 98206 Fluke Europe B.V. For volts, crest factor of reading] + [counts]) 2.0 % + 3 2.0 % + 3 (dc, 45 Hz to 500 Hz) 4.0 %...
Fluke 116 Users Manual
Page 15
Measuring Capacitance True-rms Multimeter Making Basic Measurements Measuring Temperature RANGE eeo05f.eps Vent or 80BK Type K Pipe Thermocouple Probe eeo10f.eps XW Warning To avoid risk of electric shock, do NOT connect 80BK to live circuits. 13
Measuring Capacitance True-rms Multimeter Making Basic Measurements Measuring Temperature RANGE eeo05f.eps Vent or 80BK Type K Pipe Thermocouple Probe eeo10f.eps XW Warning To avoid risk of electric shock, do NOT connect 80BK to live circuits. 13
Fluke 116 Users Manual
Page 23
... is normal for this and other true-rms meters to display nonzero readings when the test leads are disconnected from a circuit or are dc-coupled. [2] Temperature uncertainty (accuracy) does not include the error of ≤3 at 4000 counts, decreasing linearly to 50 kHz. 21 AC volts is ac coupled and specified... from 5 Hz to 1.5 at full scale. Auto-V LoZ, AC mV, and AC μA are shorted together. For volts and μA, crest factor of the thermocouple probe. [3] Frequency is ac-coupled.
... is normal for this and other true-rms meters to display nonzero readings when the test leads are disconnected from a circuit or are dc-coupled. [2] Temperature uncertainty (accuracy) does not include the error of ≤3 at 4000 counts, decreasing linearly to 50 kHz. 21 AC volts is ac coupled and specified... from 5 Hz to 1.5 at full scale. Auto-V LoZ, AC mV, and AC μA are shorted together. For volts and μA, crest factor of the thermocouple probe. [3] Frequency is ac-coupled.