Calibration Manual - Page 1
... Tests (page 7) • Calibration Adjustment (page 12) • Replacement Parts and Accessories (page 17) • Complete Warranty (page 19)
See the 114, 115, 117 Users Manual or the 115C, 117C Users Manual or the 116 Users Manuals or the 116C Users Manual for the use of the Fluke Models 114, 115, 115C, 116, 116C, 117, and 117C True RMS Multimeters...
Calibration Manual - Page 2
...8226; Verify the Meter's operation by measuring a known voltage. 114, 115, 116, and 117 Calibration Information
Safety Information
"Warning" and "Caution"... this manual or the protection provided by local or national authorities
when working alone. • Use only the replacement fuse...the Meter only as specified in doubt, have
the Meter serviced. • Do not apply more than the rated voltage,...
Calibration Manual - Page 3
....
Table 1.
General Specifications
Maximum voltage between any terminal and earth ground 600 V Surge Protection 6 kV peak per IEC 61010-1 600V CAT III,
Pollution Degree 2 W Fuse for A input (115 & 117 only 11 A, 1000 V FAST 17 kA Fuse (Fluke PN 803293) Display Digital: 6,000 counts, updates 4/sec
Bar Graph: 33 segments, updates 32/sec Temperature Operating: -10...
Calibration Manual - Page 4
...Model[1] 114, 115, 116, 117
0.5 % + 2
114, 115, 116, 117
DC, 45 to 500 Hz 2.0 % + 3
45 to 500 Hz 1.0 % + 3
500 Hz to 1 kHz 4.0 % + 3
500 Hz to 1 kHz 2.0 % + 3
114, 116, 117 114, 115, 116, 117
1.0 % + 3
2.0 % + 3
114, 115...
seconds maximum, 10
minutes rest minimum.
114, 115, 116, and 117 Calibration Information
Accuracy Specifications
Function
Range
DC millivolts DC Volts
600.0 mV
...
Calibration Manual - Page 5
...model. AC Amps Hz is specified from a circuit or are disconnected from 0.0 V. Digital Multimeters Basic Maintenance
Accuracy Specifications (cont)
Function
Range
Resolution
Accuracy ± ([% of Reading] + [Counts])
Model...Temperature uncertainty (accuracy) does not include the error of ≤3.
For example, those rows containing model 115 are applicable to the 115C as well.
[2]...
Calibration Manual - Page 7
...repair is referred to the case top and secure with a damp cloth and mild detergent. Recommended Equipment
5500A Multi-product Calibrator (or equivalent)
Table 2. Insert
the Meter into its specifications... Use only Fluke PN 803293...(115, 116, and 117) AC Volts AC Current (115, 116, and 117) Resistance
Capacitance (115,...replace with an 11 A, 1000 V, FAST fuse having a minimum
interrupt rating...
Calibration Manual - Page 8
... Meter to do so. To prepare for clarity and contrast. Required Equipment (cont)
Recommended Equipment
Measurement Function
5500A Multi-product Calibrator (or equivalent)
Frequency (115, 116, and 117)
Fluke 80 AK
Temperature (116)
K-type Thermocouple Adapter Accessory
K-type Thermocouple, mini-plug on . Compare the display with the example in standby mode (STBY...
Calibration Manual - Page 10
... DMM Performance Tests (cont)
Function
L
DC Volts
Range
Applied
6.000V
0V
6.000V
5V
114[1]
Display Reading
115[1]
116[1]
-0.002 to 0.002
4.973 to 5.027
117[1]
60.00V
50V
49.73 to 50.27
...919 881 to 919
LoZ Capacitance
10.00 μF 9 μF
N/A
7.18 to 10.82
Set calibrator to standby, reconfigure leads, and program for amps output
A DC Amps
10.00 A
10A
9.87 to
9.87...
Calibration Manual - Page 11
...Function
41
VoltAlert
Range
Hi
Applied
42
VoltAlert
Lo
114[1] N/A N/A
Display Reading
115[1]
116[1]
N/A
N/A
N/A
N/A
117[1]
Refer to steps 1 - 5
...strength, in steps 4 and 8 below
[1] If using a Fluke 9100 calibrator, the Calibrator Frequency mode must be used to ... Press the q(display should indicate 'Lo' range).
7. Set the calibrator's output to performing the test.
• Keep...
Calibration Manual - Page 15
Calibration Adjustment Steps
Rotary Switch Position
Calibration Steps
114
115[1]
116[1]
117[1,2]
Input Terminals
Calibrator Source Value
e
Ohms
m
N/A
C/01
C/01
C/01[2]
No ... Meter will not operate correctly. A
$
AC μamps
Set calibrator to changing the function switch position and after completing adjustment of each function. Digital Multimeters Calibration Adjustment
Notes...
Calibration Manual - Page 16
These devices can produce errors in this column also refer to the "C" version of the model. Calibration Adjustment Steps (cont)
Rotary Switch Position
Calibration Steps
114
115[1]
116[1]
117[1,2]
Input Terminals
Calibrator Source Value
$
N/A
N/A
C/23
N/A
DC μamps
+ and COM
600 μA, 0 Hz
[1] Models listed in the VoltAlert calibration.
[3] Wait an additional 5 seconds...
Calibration Manual - Page 18
...
Table 5. Replacable Parts List
Description
LCD,FLUKE-11X,3.2V,TN,4-DIGIT,1/4-DUTY,1/3-BIAS,LEPTON CONNECTOR,ELASTOMERIC,.010 IN CTR,.218 IN HIGH,.090 IN THK,2.284 IN LONG,BULK FLUKE-117-2006,BRACKET MASK, 117 FLUKE-117-2006-06,BRACKET MASK, 117 China FLUKE-117-2006-01,BRACKET MASK, 114 FLUKE-117-2006-02,BRACKET MASK, 115 FLUKE-117...
Calibration Manual - Page 19
... Service Center with a description of operation or handling. Replaceable Parts List
Description
BATTERY,PRIMARY,MNO2ZN,9V,505MAH,6LR61,ALKALINE, 17X26X48MM,BULK FLUKE 12-8004,SHOCK ABSORBER FLUKE-117-2005,TILT STAND FLUKE-117-2005,TILT STAND, 11X China FLUKE-117-2010,HOLSTER FLUKE-117-2010,HOLSTER, 11X China FUSE,11A,1000V,FAST.406INX1.5IN,BULK MANUAL,114/115/117 USERS MANUAL...
Quick Start Guide - Page 1
...copying values into your notes!) RANGE: selects between the models) are (bold represents the ones we'll use the...settings are finished using the meter. At best, measuring an energized component will blow a fuse inside the meter. ●))): continuity tester (audible ohmmeter).
At worst it will give incorrect values. FLUKE 112 / 115 TRUE RMS MULTIMETER Quick Start Guide
The Fluke 112 / 115...
Quick Start Guide - Page 2
... you can use, depending on one of the "A" positions. DC, AC), -range settings being measured (volts, amps, ohms, farads, hertz; When measuring voltage, resistance, diodes, capacitors, resistance or ... When the meter is being used (auto, or manual and the present range setting), -display settings (Hold, Min, Max, Avg), -instrument settings (e.g.
When the red cord is in tight spaces.