Fluke 114,115,117 Manual
Page 1
Printed in China All product names are trademarks of their respective companies. ® 114, 115, and 117 True-rms Multimeters Users Manual PN 2572573 July 2006, Rev. 1, 2/07 © 2006, 2007 Fluke Corporation, All rights reserved.
Printed in China All product names are trademarks of their respective companies. ® 114, 115, and 117 True-rms Multimeters Users Manual PN 2572573 July 2006, Rev. 1, 2/07 © 2006, 2007 Fluke Corporation, All rights reserved.
Fluke 114,115,117 Manual
Page 3
...manual applies to or from transient impulses. When making frequency measurements >1 kHz, the Y symbol is briefly displayed and an audible beep sounds when you to check that the test leads are designed to make a measurement with a 6000-count display and a bar graph. True-rms Multimeters Introduction The Fluke Model 114..., Model 115, and Model 117 are battery-powered, true-rms multimeters (hereafter "the Meter") with a lead in an incorrect terminal. These meters...
...manual applies to or from transient impulses. When making frequency measurements >1 kHz, the Y symbol is briefly displayed and an audible beep sounds when you to check that the test leads are designed to make a measurement with a 6000-count display and a bar graph. True-rms Multimeters Introduction The Fluke Model 114..., Model 115, and Model 117 are battery-powered, true-rms multimeters (hereafter "the Meter") with a lead in an incorrect terminal. These meters...
Fluke 114,115,117 Manual
Page 5
...Low battery when shown on the display.) I Fuse T Double Insulated W Important Information; Contact Fluke or a D AC and DC qualified recycler for continuity before use the Auto Volts function to manual J Earth ground ~ Do not dispose of this product as required by local or national ...authorities when working alone. • Use only the replacement fuse specified or the protection may be damaged by this function's low input impedance (≈3 kΩ)(114 and 117 only). True-rms Multimeters...
...Low battery when shown on the display.) I Fuse T Double Insulated W Important Information; Contact Fluke or a D AC and DC qualified recycler for continuity before use the Auto Volts function to manual J Earth ground ~ Do not dispose of this product as required by local or national ...authorities when working alone. • Use only the replacement fuse specified or the protection may be damaged by this function's low input impedance (≈3 kΩ)(114 and 117 only). True-rms Multimeters...
Fluke 114,115,117 Manual
Page 7
... input is too large for best resolution. 114, 115, & 117 Manual Manual ranging. Briefly displayed whenever the Meter's function switch is in the Auto Volts function. 114 & 117 Auto Autoranging. VWX Maximum, minimum, average or present reading displayed 114, 115, & 117 H (Red LED)... 114, 115, & 117 O Auto Volts The Meter is rotated to or from any A position. 115 & 117 5 Display freezes present reading. 114, 115, & 117 G M MIN MAX AVG mode enabled. The Meter selects the range for the selected range. 114, 115, & 117 R LEAd W Test lead alert. True-rms Multimeters ...
... input is too large for best resolution. 114, 115, & 117 Manual Manual ranging. Briefly displayed whenever the Meter's function switch is in the Auto Volts function. 114 & 117 Auto Autoranging. VWX Maximum, minimum, average or present reading displayed 114, 115, & 117 H (Red LED)... 114, 115, & 117 O Auto Volts The Meter is rotated to or from any A position. 115 & 117 5 Display freezes present reading. 114, 115, & 117 G M MIN MAX AVG mode enabled. The Meter selects the range for the selected range. 114, 115, & 117 R LEAd W Test lead alert. True-rms Multimeters ...
Fluke 114,115,117 Manual
Page 11
... displayed. 2. When connecting the test leads to Autorange and Auto is displayed. 1. Note You cannot manually change . 3. Disables beeper. Disables auto backlight off and when sleep mode is displayed when enabled. To enter the Manual Range mode, press q. True-rms Multimeters Power-Up Options Button Power-Up Options f p q g Q Turns on . Disables automatic power-down the...
... displayed. 2. When connecting the test leads to Autorange and Auto is displayed. 1. Note You cannot manually change . 3. Disables beeper. Disables auto backlight off and when sleep mode is displayed when enabled. To enter the Manual Range mode, press q. True-rms Multimeters Power-Up Options Button Power-Up Options f p q g Q Turns on . Disables automatic power-down the...
Fluke 114 Digital Multimeter Datasheet
Page 2
... true-rms meters to display non-zero readings when the test leads are disconnected from 1 % to 100% of 500 µs or longer. 0.9 % + 2 0.9 % + 1 1.5 % + 2 Notes: 1 All ac voltage ranges are specified from a circuit or are dc-coupled. 2 Frequency is ac-coupled. Ordering Information Fluke-114 Electrical Multimeter Included TL75 Test leads, holster, User's manual and 9 V battery (installed). Fluke Corporation 114...
... true-rms meters to display non-zero readings when the test leads are disconnected from 1 % to 100% of 500 µs or longer. 0.9 % + 2 0.9 % + 1 1.5 % + 2 Notes: 1 All ac voltage ranges are specified from a circuit or are dc-coupled. 2 Frequency is ac-coupled. Ordering Information Fluke-114 Electrical Multimeter Included TL75 Test leads, holster, User's manual and 9 V battery (installed). Fluke Corporation 114...