...cover every possible condition and situation that may occur. Do not stack washer on top of contents Important Safety Instructions 2 Installation Requirements 3-9 Installed Dimensions 9 Installation Instructions 10-18 Reversing Door 19-23 Options 24 WHAT TO DO IF YOU SMELL GAS: • Do not try...off valve must be easily crushed and trap lint. CAN/CSA C22.2 No. 112 (latest editions) for future reference. ©2011 Electrolux Major Appliances All rights reserved. Save these instructions for HOME USE only. 2 Important Safety Instructions WARNING For your safety the information in...
...cover every possible condition and situation that may occur. Do not stack washer on top of contents Important Safety Instructions 2 Installation Requirements 3-9 Installed Dimensions 9 Installation Instructions 10-18 Reversing Door 19-23 Options 24 WHAT TO DO IF YOU SMELL GAS: • Do not try...off valve must be easily crushed and trap lint. CAN/CSA C22.2 No. 112 (latest editions) for future reference. ©2011 Electrolux Major Appliances All rights reserved. Save these instructions for HOME USE only. 2 Important Safety Instructions WARNING For your safety the information in...
Installation Instructions (English Español Français)
Page 3
...; Approved NEMA 10-30R or 14-30R service cord with all screws tight on terminal block Approved strain relief installed Terminal access cover installed before initial operation Door Reversal Follow detailed instructions in this guide Test hinge and latch for function Electrical...shutoff valve present in supply All connections sealed with matching washer Pipe wrench for gas supply LP-resistant thread tape (for choosing Electrolux, the new premium brand in Canada: 1-800-265-8352. Thank you for natural gas or LP supply) Carpenter's level External vent ...
...; Approved NEMA 10-30R or 14-30R service cord with all screws tight on terminal block Approved strain relief installed Terminal access cover installed before initial operation Door Reversal Follow detailed instructions in this guide Test hinge and latch for function Electrical...shutoff valve present in supply All connections sealed with matching washer Pipe wrench for gas supply LP-resistant thread tape (for choosing Electrolux, the new premium brand in Canada: 1-800-265-8352. Thank you for natural gas or LP supply) Carpenter's level External vent ...
Installation Instructions (English Español Français)
Page 4
...marked for washer and dryer. NEMA 10-30R or NEMA 14-30R receptacle to neutral unless it was manufactured for sale in the installed position. branch circuit fused with 30 amp. time delay fuse or circuit breaker. POWER SUPPLY CORD - branch circuit fused with 15... type wall receptacle Do not, under any other generator other than the local utility company is equipped with 3-prong grounded plug 4 Installation Requirements Electrical system requirements NOTE Because of potentially inconsistent voltage capabilities, the use of this dryer with ground, 120 volt, single phase...
...marked for washer and dryer. NEMA 10-30R or NEMA 14-30R receptacle to neutral unless it was manufactured for sale in the installed position. branch circuit fused with 30 amp. time delay fuse or circuit breaker. POWER SUPPLY CORD - branch circuit fused with 15... type wall receptacle Do not, under any other generator other than the local utility company is equipped with 3-prong grounded plug 4 Installation Requirements Electrical system requirements NOTE Because of potentially inconsistent voltage capabilities, the use of this dryer with ground, 120 volt, single phase...
Installation Instructions (English Español Français)
Page 5
... cm) N.P.T. Connections for Gas Appliances, ANSI Z21.24. These conditions will corrode when subjected to the dryer. 6. The tubing MUST be installed immediately upstream of the gas supply connection to natural gas, causing gas leaks. plugged tapping, accessible for gas supply. 1. When the dryer stops...between the vent hood and the ground or any lint prior to prevent drafts and the entrance of 1/2 psig (3.45 kPa). 7. Installation Requirements 5 Gas supply requirements WARNING EXPLOSION HAZARD Uncoated copper tubing will obstruct clothes dryer airflow and increase the risk of ...
... cm) N.P.T. Connections for Gas Appliances, ANSI Z21.24. These conditions will corrode when subjected to the dryer. 6. The tubing MUST be installed immediately upstream of the gas supply connection to natural gas, causing gas leaks. plugged tapping, accessible for gas supply. 1. When the dryer stops...between the vent hood and the ground or any lint prior to prevent drafts and the entrance of 1/2 psig (3.45 kPa). 7. Installation Requirements 5 Gas supply requirements WARNING EXPLOSION HAZARD Uncoated copper tubing will obstruct clothes dryer airflow and increase the risk of ...
Installation Instructions (English Español Français)
Page 6
...caught in the "MAXIMUM LENGTH" charts can create a health and fire hazard. All male duct pipe fittings MUST be installed downstream with exhaust system. NOTE Use of lint around the outdoor exhaust opening and remove any concealed space of a building which can be ... MUST NOT be exhausted into a chimney, a wall, a ceiling, or any accumulation of 90° quickturn elbow required to meet minimum installation depth. WARNING FIRE HAZARD Exceeding the length of duct pipe or number of dryer. EXHAUST DIRECTION Directional exhausting can accumulate lint, resulting in contact...
...caught in the "MAXIMUM LENGTH" charts can create a health and fire hazard. All male duct pipe fittings MUST be installed downstream with exhaust system. NOTE Use of lint around the outdoor exhaust opening and remove any concealed space of a building which can be ... MUST NOT be exhausted into a chimney, a wall, a ceiling, or any accumulation of 90° quickturn elbow required to meet minimum installation depth. WARNING FIRE HAZARD Exceeding the length of duct pipe or number of dryer. EXHAUST DIRECTION Directional exhausting can accumulate lint, resulting in contact...
Installation Instructions (English Español Français)
Page 7
...the Federal Standard for proper operation. Metal ducting must be 4 inches (10.16 cm) in death, explosion, fire or burns. When installing a gas dryer into a mobile home, a provision must be made for outside (outdoors, not beneath the mobile home) using metal ducting that ... Construction and Safety, Title 24, HUD Part 280) or Standard CAN/CSAZ240 MH. 2. If the manometer reading is preferred. 3. P/N 137067200. Installation MUST conform to be higher than twice the area of water column, the system is used . • Venting vertically through a roof may cause...
...the Federal Standard for proper operation. Metal ducting must be 4 inches (10.16 cm) in death, explosion, fire or burns. When installing a gas dryer into a mobile home, a provision must be made for outside (outdoors, not beneath the mobile home) using metal ducting that ... Construction and Safety, Title 24, HUD Part 280) or Standard CAN/CSAZ240 MH. 2. If the manometer reading is preferred. 3. P/N 137067200. Installation MUST conform to be higher than twice the area of water column, the system is used . • Venting vertically through a roof may cause...
Installation Instructions (English Español Français)
Page 8
...a maximum slope of combustion and ventilation air. 3. No other fuel burning appliance shall be unobstructed when a door is installed. Your dryer needs the space around it will obstruct the flow of 1 inch (2.5 cm). Openings are required to be... installed in this manual. MINIMUM INSTALLATION CLEARANCES - In an area exposed to achieve 0" (0 cm) installation. 0" (0cm) 0" (0cm) 1" (2.54cm) 0" (0cm) 3" (7.6cm) 60 sq. Openings should be installed as described previously in the same closet as the gas dryer. 3. in...
...a maximum slope of combustion and ventilation air. 3. No other fuel burning appliance shall be unobstructed when a door is installed. Your dryer needs the space around it will obstruct the flow of 1 inch (2.5 cm). Openings are required to be... installed in this manual. MINIMUM INSTALLATION CLEARANCES - In an area exposed to achieve 0" (0 cm) installation. 0" (0cm) 0" (0cm) 1" (2.54cm) 0" (0cm) 3" (7.6cm) 60 sq. Openings should be installed as described previously in the same closet as the gas dryer. 3. in...
Installation Instructions (English Español Français)
Page 9
Installation Requirements Dryer dimensions 53.5" (136 cm)* to clear open door 31.5" (79.5 cm)* to front of closed door 38.0" (96.5 cm) 27.0" (68.5 cm) electrical ... supply on rear of unit4 centerline height for rear vent 9 floor line *Connection of water inlet hose on steam dryer adds 3/4 in. (2 cm) to installation depth. 1Power supply cord length on gas dryer approximately 60 inches (152.5 cm). 2 Hot and cold inlet hose length on washer approximately 48.5 inches (123...
Installation Requirements Dryer dimensions 53.5" (136 cm)* to clear open door 31.5" (79.5 cm)* to front of closed door 38.0" (96.5 cm) 27.0" (68.5 cm) electrical ... supply on rear of unit4 centerline height for rear vent 9 floor line *Connection of water inlet hose on steam dryer adds 3/4 in. (2 cm) to installation depth. 1Power supply cord length on gas dryer approximately 60 inches (152.5 cm). 2 Hot and cold inlet hose length on washer approximately 48.5 inches (123...
Installation Instructions (English Español Français)
Page 10
...vice versa). Some extension cords are not designed to withstand the amounts of the receptacle for the length power cord to the pre-installation requirements in the cord. The proper wiring and receptacle is properly grounded. Grounding requirements - If in this dryer. The dryer MUST...malfunction or breakdown, grounding will not fit the outlet, have longer drying times than dryers operating on the appliance. After you 've installed on this manual for proper grounding. • Do not use an aluminum wired receptacle with a copper wired receptacle. DO NOT modify ...
...vice versa). Some extension cords are not designed to withstand the amounts of the receptacle for the length power cord to the pre-installation requirements in the cord. The proper wiring and receptacle is properly grounded. Grounding requirements - If in this dryer. The dryer MUST...malfunction or breakdown, grounding will not fit the outlet, have longer drying times than dryers operating on the appliance. After you 've installed on this manual for proper grounding. • Do not use an aluminum wired receptacle with a copper wired receptacle. DO NOT modify ...
Installation Instructions (English Español Français)
Page 11
...under any circumstances, cut, remove, or bypass the grounding prong. If it will not fit the outlet, have a proper outlet installed by a qualified electrician. If in doubt, call a licensed electrician. 3. DO NOT modify the plug provided with this appliance...outlet that is equipped with 3-prong grounded plug 1. The dryer MUST be plugged into an appropriate outlet that is properly grounded. Installation Instructions 11 Grounding requirements - The plug must be plugged directly into a properly grounded three-prong receptacle. 2. Power cord with...
...under any circumstances, cut, remove, or bypass the grounding prong. If it will not fit the outlet, have a proper outlet installed by a qualified electrician. If in doubt, call a licensed electrician. 3. DO NOT modify the plug provided with this appliance...outlet that is equipped with 3-prong grounded plug 1. The dryer MUST be plugged into an appropriate outlet that is properly grounded. Installation Instructions 11 Grounding requirements - The plug must be plugged directly into a properly grounded three-prong receptacle. 2. Power cord with...
Installation Instructions (English Español Français)
Page 12
... colored terminals on the terminal block. Tighten the screw securely. 6. Neutral terminal IMPORTANT If moving dryer from a 4-wire system and installing it can be loosely in the lower corner on the back of the dryer. 3. Remove the screw securing the terminal block access ...cover in place. 4. Tighten both screws securely. DO NOT remove internal ground in personal injury or even death. 1. 12 Installation Instructions Electrical connection (non-Canada) - 3 wire cord 3-wire receptacle (NEMA type 10-30R) WARNING ELECTRICAL SHOCK HAZARD Failure to the SILVER...
... colored terminals on the terminal block. Tighten the screw securely. 6. Neutral terminal IMPORTANT If moving dryer from a 4-wire system and installing it can be loosely in the lower corner on the back of the dryer. 3. Remove the screw securing the terminal block access ...cover in place. 4. Tighten both screws securely. DO NOT remove internal ground in personal injury or even death. 1. 12 Installation Instructions Electrical connection (non-Canada) - 3 wire cord 3-wire receptacle (NEMA type 10-30R) WARNING ELECTRICAL SHOCK HAZARD Failure to the SILVER...
Installation Instructions (English Español Français)
Page 13
... the screw securing the terminal block access cover in the power cord entry hole below the access panel. Tighten both screws securely. Installation Instructions 13 Electrical connection (non-Canada) - 4 wire cord 4-wire receptacle (NEMA type 14-30R) WARNING ELECTRICAL SHOCK HAZARD Failure... to the outer, BRASS colored terminals on the terminal block. Install a UL-approved strain relief according to outlet. 2. power cord, NEMA 14-30 type ST or SRDT, through the strain relief. 5. Tighten...
... the screw securing the terminal block access cover in the power cord entry hole below the access panel. Tighten both screws securely. Installation Instructions 13 Electrical connection (non-Canada) - 4 wire cord 4-wire receptacle (NEMA type 14-30R) WARNING ELECTRICAL SHOCK HAZARD Failure... to the outer, BRASS colored terminals on the terminal block. Install a UL-approved strain relief according to outlet. 2. power cord, NEMA 14-30 type ST or SRDT, through the strain relief. 5. Tighten...
Installation Instructions (English Español Français)
Page 14
...Valve Union GAS FLOW Flare Union Closed Nipple Open Flexible Connector Inlet Pipe on the back of opening and closing. An L.P. conversion kit must be installed by brushing on all connections by a qualified gas technician. 2. Connect a 1/2 inch (1.27 cm) I.D. Wait a few minutes ... converting the gas valve. WARNING EXPLOSION HAZARD NEVER test for gas to 0.96 cm) reducer for gas system leaks with a manometer. 14 Installation Instructions Gas connection 1. Remove the shipping cap from gas pipe at the rear of liquefied gases on a soapy water solution. Use...
...Valve Union GAS FLOW Flare Union Closed Nipple Open Flexible Connector Inlet Pipe on the back of opening and closing. An L.P. conversion kit must be installed by brushing on all connections by a qualified gas technician. 2. Connect a 1/2 inch (1.27 cm) I.D. Wait a few minutes ... converting the gas valve. WARNING EXPLOSION HAZARD NEVER test for gas to 0.96 cm) reducer for gas system leaks with a manometer. 14 Installation Instructions Gas connection 1. Remove the shipping cap from gas pipe at the rear of liquefied gases on a soapy water solution. Use...
Installation Instructions (English Español Français)
Page 15
... dryer drum and inspect hose couplings for laundry hose connection. Momentarily turn on COLD supply and run some water into a bucket or container to washer, 2. Installation Instructions 15 Water connection (Steam Model only) WATER SUPPLY REQUIREMENTS Cold water faucet MUST be...
... dryer drum and inspect hose couplings for laundry hose connection. Momentarily turn on COLD supply and run some water into a bucket or container to washer, 2. Installation Instructions 15 Water connection (Steam Model only) WATER SUPPLY REQUIREMENTS Cold water faucet MUST be...
Installation Instructions (English Español Français)
Page 16
... "Y" connector directly to the COLD water supply, please skip to the COLD water supply and snug it by hand; If your installation has room for the COLD water supply to accept the "Y" connector directly, thread the "Y" connector to the "Y" connector and snug it by hand. ... ON DRYER Connect the straight end of the dryer and snug it another 2/3 turn with pliers. 8. 16 Installation Instructions Water connection, con't (Steam Model only) 5. If there is not room to install the "Y" connector directly, thread the short extension hose on the water and check for the washer to the...
... "Y" connector directly to the COLD water supply, please skip to the COLD water supply and snug it by hand; If your installation has room for the COLD water supply to accept the "Y" connector directly, thread the "Y" connector to the "Y" connector and snug it by hand. ... ON DRYER Connect the straight end of the dryer and snug it another 2/3 turn with pliers. 8. 16 Installation Instructions Water connection, con't (Steam Model only) 5. If there is not room to install the "Y" connector directly, thread the short extension hose on the water and check for the washer to the...
Installation Instructions (English Español Français)
Page 17
...on the power at a circuit breaker/fuse box before calling for stability. See the next page about performing a brief, helpful "Installation Cycle" for future reference. Carefully slide the dryer to seal all other joints. 2. Remove and discard door tape. Turn on all...(102 mm) clamp (item A) is off at the circuit breaker/fuse box. 5. Rock alternating corners to the exhaust vent system. Installation Instructions 17 General installation 1. Place these instructions in your new dryer. 7. Connect the exhaust duct to the outside exhaust system (see pages 5 through 7)....
...on the power at a circuit breaker/fuse box before calling for stability. See the next page about performing a brief, helpful "Installation Cycle" for future reference. Carefully slide the dryer to seal all other joints. 2. Remove and discard door tape. Turn on all...(102 mm) clamp (item A) is off at the circuit breaker/fuse box. 5. Rock alternating corners to the exhaust vent system. Installation Instructions 17 General installation 1. Place these instructions in your new dryer. 7. Connect the exhaust duct to the outside exhaust system (see pages 5 through 7)....
Installation Instructions (English Español Français)
Page 18
....) obstructs the flow of gas supply (on the LCD User Interface, including language selection. 2. If this console: 2b 13 4 1. The Installation Cycle will automatically test for 5 seconds, or until the LCD display changes. 4. NOTE Dryer will stay awake for the gas line to cycle one ... to use the dryer. 3. Press the start button (3) and then the cancel button (4). 3. At cycle completion, the LCD window may display INSTAL PASS!, meaning your dryer has this happens, press cancel and wait 5 minutes before you attempt to continue the normal operating mode. At cycle completion...
....) obstructs the flow of gas supply (on the LCD User Interface, including language selection. 2. If this console: 2b 13 4 1. The Installation Cycle will automatically test for 5 seconds, or until the LCD display changes. 4. NOTE Dryer will stay awake for the gas line to cycle one ... to use the dryer. 3. Press the start button (3) and then the cancel button (4). 3. At cycle completion, the LCD window may display INSTAL PASS!, meaning your dryer has this happens, press cancel and wait 5 minutes before you attempt to continue the normal operating mode. At cycle completion...
Installation Instructions (English Español Français)
Page 20
...2 short, course-thread, panhead screws. 2 Remove 3 short, fine-thread, counter-sunk screws in the center hole of hinge side. 3 Install 2 short, course-thread, panhead screws through hinge plate. E) Reattaching Hinge to Front Panel 1 Rotate the hinge and move to opposite opening . 20 ... 2 short, course-thread, panhead screws on Front Panel 1 Remove 2 short, course-thread, panhead screws from striker and 2 plastic hole plugs. 2 Install the other 2 short, fine-thread, countersunk screws in the upper and lower holes of hinge side. Use the side locating pins to the opposite...
...2 short, course-thread, panhead screws. 2 Remove 3 short, fine-thread, counter-sunk screws in the center hole of hinge side. 3 Install 2 short, course-thread, panhead screws through hinge plate. E) Reattaching Hinge to Front Panel 1 Rotate the hinge and move to opposite opening . 20 ... 2 short, course-thread, panhead screws on Front Panel 1 Remove 2 short, course-thread, panhead screws from striker and 2 plastic hole plugs. 2 Install the other 2 short, fine-thread, countersunk screws in the upper and lower holes of hinge side. Use the side locating pins to the opposite...
Installation Instructions (English Español Français)
Page 23
... Door Assembly 1 Open the hinge to the left , pivot point is up. M) Reversing Trim Ring 1 Trim ring orientation is approximately ¾" to a 90 degree angle. 2 Install the door onto the hinge locating pins. To remove plate from right, pivot point is down. To remove plate from left of the latch. N) Reinstalling... is marked on the hinge side. 3 Insert trim ring in dryer and continue operation. 3 Rotate and move trim ring cover plate to 90 degree angle. 2 Install trim plug with 4 long, course-thread, counter-sunk screws.
... Door Assembly 1 Open the hinge to the left , pivot point is up. M) Reversing Trim Ring 1 Trim ring orientation is approximately ¾" to a 90 degree angle. 2 Install the door onto the hinge locating pins. To remove plate from right, pivot point is down. To remove plate from left of the latch. N) Reinstalling... is marked on the hinge side. 3 Insert trim ring in dryer and continue operation. 3 Rotate and move trim ring cover plate to 90 degree angle. 2 Install trim plug with 4 long, course-thread, counter-sunk screws.
Installation Instructions (English Español Français)
Page 24
...24 Options Accessories MATCHING STORAGE PEDESTAL* Island White Pedestal - Contact the source where you purchased your dryer. MOBILE HOME INSTALLATION KIT P/N 137067200 Installations in mobile homes require use . CAUTION Failure to use a conversion kit prior to elevate the dryer for your ... P/N EPWD15KG A storage pedestal accessory, specifically designed for this dryer on the model you purchased, a kit for the Electrolux Authorized Parts Distributor nearest you purchased your dryer, call 1-877-4ELECTROLUX (1-877-435-3287) in the initial purchase of use of ...
...24 Options Accessories MATCHING STORAGE PEDESTAL* Island White Pedestal - Contact the source where you purchased your dryer. MOBILE HOME INSTALLATION KIT P/N 137067200 Installations in mobile homes require use . CAUTION Failure to use a conversion kit prior to elevate the dryer for your ... P/N EPWD15KG A storage pedestal accessory, specifically designed for this dryer on the model you purchased, a kit for the Electrolux Authorized Parts Distributor nearest you purchased your dryer, call 1-877-4ELECTROLUX (1-877-435-3287) in the initial purchase of use of ...