EMC SmartFabric OS10 Switch Configuration Guide for VxRail 4.7
Page 20
.... Save? [yes/no]:n Proceed to reboot the system? [confirm yes/no (default)]:y OS10# reload System configuration has been modified. Dell EMC PowerSwitches running SmartFabric OS10 can also be reset to their factory default settings. 6.3 Factory default configuration The configuration commands in the sections that follow begin with S5248F-ON switches at its default settings...
.... Save? [yes/no]:n Proceed to reboot the system? [confirm yes/no (default)]:y OS10# reload System configuration has been modified. Dell EMC PowerSwitches running SmartFabric OS10 can also be reset to their factory default settings. 6.3 Factory default configuration The configuration commands in the sections that follow begin with S5248F-ON switches at its default settings...
VCF on VxRail Multirack Deployment using BGP EVPN
Page 25
...configuration. Save? [yes/no]:n Proceed to a complex password during the first login. 25 VCF on the switch if OS10EE was factory installed. The default username and password are both admin. 5.7 Version : License Type : License Duration: License Status : License ...reboot the system? [confirm yes/no (default)]:y OS10# reload System configuration has been modified. Dell EMC PowerSwitches running OS10EE can be reset to their factory default settings. Factory default configuration The switch configuration commands in the chapters that follow begin with the leaf switches at...
...configuration. Save? [yes/no]:n Proceed to a complex password during the first login. 25 VCF on the switch if OS10EE was factory installed. The default username and password are both admin. 5.7 Version : License Type : License Duration: License Status : License ...reboot the system? [confirm yes/no (default)]:y OS10# reload System configuration has been modified. Dell EMC PowerSwitches running OS10EE can be reset to their factory default settings. Factory default configuration The switch configuration commands in the chapters that follow begin with the leaf switches at...
EMC Solutions for Microsoft Azure Stack HCI Networking Guide
Page 3
......2 1 Introduction...6 1.1 Typographical conventions...6 1.2 Attachments...6 2 Hardware Overview...7 2.1 Dell EMC Networking S5248F-ON ...7 2.2 Dell EMC Networking S3048-ON ...7 2.3 Dell EMC S2D Ready Nodes...7 2.4 Management system ...8 2.5 Supported Dell EMC Networking switches...8 3 Topology...9 3.1 Connections to leaf switches ...10 3.2 ...Adapter/RDMA/DCB options ...13 4.5 VLANs and IP addressing ...13 5 Configure network adapters ...14 5.1 Reset network adapters to factory defaults ...14 5.2 Configure QLogic QL41262 adapters...15 5.3 Verify Mellanox ConnectX-4 Lx adapter settings 19 6 ...
......2 1 Introduction...6 1.1 Typographical conventions...6 1.2 Attachments...6 2 Hardware Overview...7 2.1 Dell EMC Networking S5248F-ON ...7 2.2 Dell EMC Networking S3048-ON ...7 2.3 Dell EMC S2D Ready Nodes...7 2.4 Management system ...8 2.5 Supported Dell EMC Networking switches...8 3 Topology...9 3.1 Connections to leaf switches ...10 3.2 ...Adapter/RDMA/DCB options ...13 4.5 VLANs and IP addressing ...13 5 Configure network adapters ...14 5.1 Reset network adapters to factory defaults ...14 5.2 Configure QLogic QL41262 adapters...15 5.3 Verify Mellanox ConnectX-4 Lx adapter settings 19 6 ...
EMC Solutions for Microsoft Azure Stack HCI Networking Guide
Page 14
In the virtual console, from their factory default settings. 1. Reboot the server. 4. On the Device Settings page, click the first network adapter port in the device list 14 Dell EMC Solutions for the port. Connect to the server's iDRAC in this section may vary ...depending on hardware, software and browser versions used. On the System Setup Main Menu page, select Device Settings. First NIC port in the list to the iDRAC. Device Settings menu item 5. Reset network adapters to factory...
In the virtual console, from their factory default settings. 1. Reboot the server. 4. On the Device Settings page, click the first network adapter port in the device list 14 Dell EMC Solutions for the port. Connect to the server's iDRAC in this section may vary ...depending on hardware, software and browser versions used. On the System Setup Main Menu page, select Device Settings. First NIC port in the list to the iDRAC. Device Settings menu item 5. Reset network adapters to factory...
EMC Solutions for Microsoft Azure Stack HCI Networking Guide
Page 23
...# delete startup-configuration Proceed to delete startup-configuration [confirm yes/no ]:y The switch reboots to its factory default configuration. The default username and password are both admin. Dell EMC Networking switches running OS10EE can be reset to their factory default settings. Save? [yes/no]:n Proceed to reboot the system? [confirm yes/no (default)]:y OS10...
...# delete startup-configuration Proceed to delete startup-configuration [confirm yes/no ]:y The switch reboots to its factory default configuration. The default username and password are both admin. Dell EMC Networking switches running OS10EE can be reset to their factory default settings. Save? [yes/no]:n Proceed to reboot the system? [confirm yes/no (default)]:y OS10...
EMC Networking Virtualization Overlay with BGP EVPN
Page 20
...profile-3 is specific to a complex password during the first login. To change the switch port profile from its default setting to its factory default configuration. Disregard this deployment example. Save? [yes/no]:n Proceed to reboot the system? [confirm yes/no (default)]:y OS10...configuration has been modified. The default username and password are currently supported on Ethernet and unified ports. Dell EMC PowerSwitches running OS10EE can be reset to their factory default settings. A switch port profile determines the enabled front-panel ports and supported breakout modes on the...
...profile-3 is specific to a complex password during the first login. To change the switch port profile from its default setting to its factory default configuration. Disregard this deployment example. Save? [yes/no]:n Proceed to reboot the system? [confirm yes/no (default)]:y OS10...configuration has been modified. The default username and password are currently supported on Ethernet and unified ports. Dell EMC PowerSwitches running OS10EE can be reset to their factory default settings. A switch port profile determines the enabled front-panel ports and supported breakout modes on the...
EMC S3048-ON and S4048-ON Troubleshooting Guide March 2019
Page 16
... settings. If it is highlighted. After ONIE Rescue completes, the system resets and boots to do this with the operating system you installed, reboot ...line. Erasing internal mass storage device: /dev/mmcblk0 (7832MB) Percent complete: 100% 16 Dell EMC diagnostics Serial Number Sevice Tag : TW0T9FNW2829849Q0041 : AEIOU## Fantray Info: FanTray[1] AirFlow ...TW0MGDH82829849Q0003 : AEIOU## : NORMAL : 0MGDH8 : TW0MGDH82829849Q0001 : AEIOU## Factory defaults restore If you need to restore the S4048-ON or S3048-ON factory defaults, reboot the system to erase storage. Use the up and ...
... settings. If it is highlighted. After ONIE Rescue completes, the system resets and boots to do this with the operating system you installed, reboot ...line. Erasing internal mass storage device: /dev/mmcblk0 (7832MB) Percent complete: 100% 16 Dell EMC diagnostics Serial Number Sevice Tag : TW0T9FNW2829849Q0041 : AEIOU## Fantray Info: FanTray[1] AirFlow ...TW0MGDH82829849Q0003 : AEIOU## : NORMAL : 0MGDH8 : TW0MGDH82829849Q0001 : AEIOU## Factory defaults restore If you need to restore the S4048-ON or S3048-ON factory defaults, reboot the system to erase storage. Use the up and ...
EMC Networking OS10 Enterprise Edition Deployment Guide with Cisco ACI
Page 4
9.3 Verify connectivity between VMs...30 A Additional information...31 A.1 Reset OS10EE switches to factory defaults...31 A.2 Spanning Tree Protocol recommendations ...31 B Validated components ...32 B.1 Dell EMC Networking switches...32 B.2 Cisco ACI components ...32 C Technical resources ...33 D Support and feedback ...34 4 Dell EMC Networking OS10 Enterprise Edition Deployment Guide with Cisco ACI
9.3 Verify connectivity between VMs...30 A Additional information...31 A.1 Reset OS10EE switches to factory defaults...31 A.2 Spanning Tree Protocol recommendations ...31 B Validated components ...32 B.1 Dell EMC Networking switches...32 B.2 Cisco ACI components ...32 C Technical resources ...33 D Support and feedback ...34 4 Dell EMC Networking OS10 Enterprise Edition Deployment Guide with Cisco ACI
EMC Networking OS10 Enterprise Edition Deployment Guide with Cisco ACI
Page 31
...# reload System configuration has been modified. MST configuration is not using RPVST+, Dell EMC Networking recommends changing to the existing spanning tree protocol before connecting an OS10EE switch. A Additional information A.1 A.2 Reset OS10EE switches to factory defaults To reset OS10EE switches back to the factory default configuration, enter the following commands: OS10# delete startup-configuration Proceed...
...# reload System configuration has been modified. MST configuration is not using RPVST+, Dell EMC Networking recommends changing to the existing spanning tree protocol before connecting an OS10EE switch. A Additional information A.1 A.2 Reset OS10EE switches to factory defaults To reset OS10EE switches back to the factory default configuration, enter the following commands: OS10# delete startup-configuration Proceed...