Dell PowerSwitch N2100 Support and Manuals

Get Help and Manuals for this Dell item

View All Support Options Below
Free Dell PowerSwitch N2100 manuals!
Problems with Dell PowerSwitch N2100?

Ask a Question

Popular Dell PowerSwitch N2100 Manual Pages

EMC Networking N-Series Switches User Guide version 6.6.2 - Page 70

... Feature Overview For information about configuring inbound Telnet settings, see "Port and System Security" on page 289. SSH/SSL The switch supports Secure Shell (SSH) for eight different types ...Control By default, the switch allows access over Telnet. Denial of Service The switch supports configurable Denial of Service (DoS) attack protection for secure, remote connections to the CLI and...
EMC Networking N-Series Switches User Guide version 6.6.2 - Page 85

...PoE Plus Support PoE Plus-capable switches implement the PoE Plus specification (IEEE 802.3at), in excess of the power limit. This allows power to be limited on the switch as part of the ... be configured manually for feeds in addition to 802.3at or 802.3at+legacy detection. Table 2-5. Power Detection Mode Sets the mode to the IEEE 802.3af specification. PoE 60W Support PoE 60W...
EMC Networking N-Series Switches User Guide version 6.6.2 - Page 1555

...support Voice over IP (VoIP). The configuration script is for a network to an interface. cos-queue random-detect 2 Apply the policy to provide acceptable service, a guaranteed transmission rate is vital. interface Te1/0/1 service... the policy. This example shows one way to provide the necessary quality of service: how to set up a class for VoIP One of the most valuable uses of DiffServ is...
EMC Networking N-Series Switches CLI Reference Guide version 6.6.2 - Page 2277

... a text description with a switch in the stack. console(config)# service unsupported-transceiver set description Use the set description unit description • unit - Command Mode Stack Configuration mode... removing an optics not qualified by Dell. The unit/slot is the index to the database of the supported card types (see the command show supported cardtype) indicating the type of the...
EMC Networking N-Series Switches User Guide version 6.6.1 - Page 67

... switch supports configurable Denial of Service (DoS) attack protection for secure, remote connections to the CLI and Secure Sockets Layer (SSL) to accept RADIUS-assigned VLANs, ACLs and DiffServ Policies. For information about configuring RADIUS client settings, see "Port and System Security" on page 253. For information about configuring DoS settings, see "Authentication, Authorization...
EMC Networking N-Series Switches User Guide version 6.6.1 - Page 1517

... diagram: a similar script should be applied to support Voice over IP (VoIP). This example shows one way to provide the necessary quality of service: how to set up a class for VoIP One of the most...be assigned to CoS queue 2 and policed per the above. Differentiated Services 1517 The configuration script is for a network to an interface. cos-queue random-detect 2 Apply ...
EMC Networking N-Series Switches User Guide version 6.6.0 - Page 65

... "Authentication, Authorization, and Accounting" on page 247. For information about configuring SSH and SSL settings, see "Authentication, Authorization, and Accounting" on page 247. RADIUS Support The switch has a Remote Authentication Dial In User Service (RADIUS) client and can support up to increase security when accessing the web-based management interface. The switch can also...
EMC Networking N-Series Switches User Guide version 6.5.1.x - Page 74

... (SSH) for eight different types of attacks. The administrator can be configured to accept RADIUS-assigned VLANs. For information about configuring RADIUS client settings, see "Authentication, Authorization, and Accounting" on page 269. Denial of Service The switch supports configurable Denial of a NAS-IP address. Additionally, the Telnet port number is the configuration of...
EMC Networking N-Series Switches CLI Reference Guide version 6.5.2 - Page 1224

... normal PAUSE control mechanism is not supported. Only ports configured as DCBX manual role utilize the configured PFC settings. Use the no form of -service must be set to one . When PFC is ... mode to carry the 802.1p value through the network. Up to their PFC settings overridden. Command Mode Datacenter-Bridging Configuration mode User Guidelines NOTE: This command is enabled...
EMC Networking N-Series Switches CLI Reference Guide version 6.5.2 - Page 2211

... renumber show supported cardtype show ...stack-ports service unsupportedtransceiver connect set description cut-...through mode slot disconnect show banner exit hardware profile portmode load-interval locate show buffers show checkpoint statistics show cut-through mode show idprom interface show interfaces show system show interfaces show system fan advanced firmware...
EMC Networking N-Series Switches CLI Reference Guide version 6.5.2 - Page 2240

... Global Configuration mode User Guidelines The switch logs a message and generates a trap on inserting or removing an optics not qualified by Dell. console(config)# service unsupported-transceiver set description Use the set the transceiver support to log a message along with a switch in the stack. Example The following on insertion or removal of an optic that...
EMC Networking N-Series Switches CLI Reference Guide version 6.5.1.x - Page 981

... to the RADIUS server for CHAP Access-Requests: 1-User-Name-MAC address of MAB device. 3-CHAP-Password = Encrypted User Name. 4-NAS-IP-Address-IP address of the switch. 5-NAS-Port-Our internal port number. 6-Service-Type is set to 10 (Call-Check). 12-Framed-MTU-Port/switch MTU-header length (for example, 1500...
EMC Networking N-Series Switches CLI Reference Guide version 6.5.1.x - Page 1209

.... Additionally, the dot1mapping to class-of-service must be set to one-to-one. Only ports configured as DCBX manual role utilize the configured PFC settings. When PFC is enabled on an interface...the command to return the mode to their PFC settings overridden. Up to use PFC will cause unexpected results and is not supported. Command Mode Datacenter-Bridging Configuration mode User Guidelines...
EMC Networking N-Series Switches CLI Reference Guide version 6.5.1.x - Page 2195

... cpu threshold quit clear checkpoint reload statistics clear counters stack-ports service unsupportedtransceiver connect set description cut-through mode slot disconnect show banner exit hardware profile ... advanced firmware show interfaces utilization show system id show memory cpu show system power show nsf show system temperature show process app- show tech-support history show...
EMC Networking N-Series Switches CLI Reference Guide version 6.3.x - Page 1201

...are configured to two lossless priorities can operate over the interface. Because PFC is not supported. Data Center Technology Commands 1199 Additionally, the dot1mapping to class-of the command to ...no form of -service must be set to one . Use the no form of the ports in a port channel. Only ports configured as DCBX manual role utilize the configured PFC settings. Only configuring ...

Dell PowerSwitch N2100 Reviews

Do you have an experience with the Dell PowerSwitch N2100 that you would like to share?
Earn 750 points for your review!
We have not received any reviews for Dell yet.

Ask a New Question
Use the box below to post a new question about Dell PowerSwitch N2100.
Manuals / Documents
Download any of our Dell PowerSwitch N2100 manuals for free!

We have the following 12 documents available for the Dell PowerSwitch N2100:
  • EMC Networking N-Series Switches CLI Reference Guide version 6.6.1
  • EMC Networking N-Series Switches CLI Reference Guide version 6.6.2
  • EMC Networking N-Series Switches CLI Reference Guide version 6.5.2
  • EMC Networking N-Series Switches CLI Reference Guide version 6.5.1.x
  • EMC Networking N-Series Switches CLI Reference Guide version 6.3.x
  • EMC Networking N-Series Switches User Guide version 6.5.2
  • EMC Networking N-Series Switches User Guide version 6.6.2
  • EMC Networking N-Series Switches User Guide version 6.5.1.x
  • EMC Networking N-Series Switches User Guide version 6.6.1
  • EMC Networking N-Series Switches User Guide version 6.6.0
  • EMC Networking N-Series Switches User Guide version 6.3.x
  • 2 More!

Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Dell Manuals

Find free Dell PowerSwitch N2100 manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Dell Reviews

View thousands of Dell PowerSwitch N2100 user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Dell customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Dell customer service rankings, employee comments and much more from our sister site.

Dell Recalls

Find comprehensive Dell recall information updated hourly on RecallOwl.com.