Service Guide
Page 102
...the drive may not match the signature on the controller. continued 3-42 Compaq ProLiant ML530 Servers Maintenance and Service Guide Table 3-20 ADU Diagnostic Messages continued Message Description...replaced in a fault tolerant logical volume. Error Code: X The controller returned an error from its configuration Drive has insufficient capacity to configure nonvolatile RAM. Drive (bay) X has insufficient capacity... moved to configure the controller and nonvolatile RAM. Drive (bay) X firmware needs upgrading Firmware on this slot, LED indicators on the system and attempt to reconnect...
...the drive may not match the signature on the controller. continued 3-42 Compaq ProLiant ML530 Servers Maintenance and Service Guide Table 3-20 ADU Diagnostic Messages continued Message Description...replaced in a fault tolerant logical volume. Error Code: X The controller returned an error from its configuration Drive has insufficient capacity to configure nonvolatile RAM. Drive (bay) X has insufficient capacity... moved to configure the controller and nonvolatile RAM. Drive (bay) X firmware needs upgrading Firmware on this slot, LED indicators on the system and attempt to reconnect...
Service Guide
Page 143
... Diagnostic LED Indicators Item Description AC power (Green) Error (Amber) Status On Flashing Off Off On All on Flashing Condition System on System in standby No AC power present Power supply operational Power supply failure-replace power supply No AC power present to any power supply Current power supply limit exceeded 4-10 Compaq ProLiant ML530...
... Diagnostic LED Indicators Item Description AC power (Green) Error (Amber) Status On Flashing Off Off On All on Flashing Condition System on System in standby No AC power present Power supply operational Power supply failure-replace power supply No AC power present to any power supply Current power supply limit exceeded 4-10 Compaq ProLiant ML530...
Service Guide
Page 157
4 Compaq ProLiant ML530 Servers Maintenance and Service Guide SCSI hard drive 3-36 SCSI tape drive 3-37 SCSI/IDE CD-ROM drive 3-36 serial port 3-30 tape drive 3-33, 3-... 4-13 location 2-19 part number 1-3 removing 2-25 removing, illustrated 2-25 replacing 2-25 signal cable connector, identified 2-34, 4-3 specifications 5-4 status LED, illustrated 4-13 test error codes 3-29 diskette drives power and signal cables identified 2-29 diskette, creating Diagnostics 3-24 door, front bezel removing 2-8 removing, illustrated 2-8 replacing 2-8 Drive Array Advanced Diagnostics ...
4 Compaq ProLiant ML530 Servers Maintenance and Service Guide SCSI hard drive 3-36 SCSI tape drive 3-37 SCSI/IDE CD-ROM drive 3-36 serial port 3-30 tape drive 3-33, 3-... 4-13 location 2-19 part number 1-3 removing 2-25 removing, illustrated 2-25 replacing 2-25 signal cable connector, identified 2-34, 4-3 specifications 5-4 status LED, illustrated 4-13 test error codes 3-29 diskette drives power and signal cables identified 2-29 diskette, creating Diagnostics 3-24 door, front bezel removing 2-8 removing, illustrated 2-8 replacing 2-8 Drive Array Advanced Diagnostics ...
Service Guide
Page 161
8 Compaq ProLiant ML530 Servers Maintenance and Service Guide technical support telephone numbers ix hot surfaces warnings 2-7, 2-10 hot-plug devices, removing 2-4 hot-plug drive ...57 IRQ conflict, resolving 3-3 J jumper and header locations, illustrated 4-5 jumper settings, obtaining 3-3 K keyboard connector, identified 4-2 interface, identified 2-34, 4-3 part number 1-6 test error codes 3-27 L LEDs CD-ROM drive status, illustrated 4-13 viewing 4-13 critical system diagnostic, illustrated 4-7 diagnostic locating 4-7 viewing 4-8 diskette drive status, illustrated 4-13 viewing 4-13 front panel...
8 Compaq ProLiant ML530 Servers Maintenance and Service Guide technical support telephone numbers ix hot surfaces warnings 2-7, 2-10 hot-plug devices, removing 2-4 hot-plug drive ...57 IRQ conflict, resolving 3-3 J jumper and header locations, illustrated 4-5 jumper settings, obtaining 3-3 K keyboard connector, identified 4-2 interface, identified 2-34, 4-3 part number 1-6 test error codes 3-27 L LEDs CD-ROM drive status, illustrated 4-13 viewing 4-13 critical system diagnostic, illustrated 4-7 diagnostic locating 4-7 viewing 4-8 diskette drive status, illustrated 4-13 viewing 4-13 front panel...
Service Guide
Page 163
10 Compaq ProLiant ML530 Servers Maintenance and Service Guide hard drive blank 1-3 hard drive cage blanking panel 1-3 hard drive cage w/backplane board 1-3 hard drives 1-3 keyboard 1-6 maintenance and service ...3-37 POST beeps, description 3-8 defined 3-7 error messages 3-7, 3-8 POST messages 3-16, 3-17, 3-20 1700 series 3-16, 3-17, 3-20 power backplane board part number 1-5 removing 2-44 removing, illustrated 2-44 replacing 2-44 power cables identified 2-27 power connectors, identified 2-34, 4-3 power down server 2-5 Power On/Standby switch LEDs, illustrated 4-6 part number 1-3 removing 2-45 ...
10 Compaq ProLiant ML530 Servers Maintenance and Service Guide hard drive blank 1-3 hard drive cage blanking panel 1-3 hard drive cage w/backplane board 1-3 hard drives 1-3 keyboard 1-6 maintenance and service ...3-37 POST beeps, description 3-8 defined 3-7 error messages 3-7, 3-8 POST messages 3-16, 3-17, 3-20 1700 series 3-16, 3-17, 3-20 power backplane board part number 1-5 removing 2-44 removing, illustrated 2-44 replacing 2-44 power cables identified 2-27 power connectors, identified 2-34, 4-3 power down server 2-5 Power On/Standby switch LEDs, illustrated 4-6 part number 1-3 removing 2-45 ...
Service Guide
Page 165
12 Compaq ProLiant ML530 Servers Maintenance and Service Guide drive fan cable and cable bracket 2-18 hard drive cage w/backplane board 2-22 hard drive fan air baffle 2-16 hot-... 4-12 status LEDs, viewing 4-12 ROM flashing 3-70 interrupting upgrade process 3-70 recovering image 3-70, 3-71 upgrading 3-70 ROMPaq disaster recovery 3-71 Firmware Upgrade Utility, accessing 3-5 interruption 3-71 ROMPaq Error Recovery Options 3-70 S SCSI cable kit, part number 1-6 SCSI cable slot, identified 4-2 SCSI CD-ROM drives See CD-ROM drives SCSI connectors...
12 Compaq ProLiant ML530 Servers Maintenance and Service Guide drive fan cable and cable bracket 2-18 hard drive cage w/backplane board 2-22 hard drive fan air baffle 2-16 hot-... 4-12 status LEDs, viewing 4-12 ROM flashing 3-70 interrupting upgrade process 3-70 recovering image 3-70, 3-71 upgrading 3-70 ROMPaq disaster recovery 3-71 Firmware Upgrade Utility, accessing 3-5 interruption 3-71 ROMPaq Error Recovery Options 3-70 S SCSI cable kit, part number 1-6 SCSI cable slot, identified 4-2 SCSI CD-ROM drives See CD-ROM drives SCSI connectors...