Compaq 323450-001 - ProLiant - 8500 Support and Manuals
Get Help and Manuals for this Compaq item
This item is in your list!
View All Support Options Below
Free Compaq 323450-001 manuals!
Problems with Compaq 323450-001?
Ask a Question
Free Compaq 323450-001 manuals!
Problems with Compaq 323450-001?
Ask a Question
Popular Compaq 323450-001 Manual Pages
ProLiant 8500 Servers Maintenance and Service Guide - Page 81
... all Compaq systems that support Compaq array controllers. System Configuration Utility
A utility to easily configure the hardware installed in or connected to run it can:
I Resolve resource conflicts in areas such as memory, port addresses, and interrupts (IRQs)
I Configure PCI boards automatically
I Provide switch and jumper settings
I Manage installation of memory, processor upgrades, and...
ProLiant 8500 Servers Maintenance and Service Guide - Page 86
...spinning. Flash the ROM as indicated. Replace the processor if the failure recurs. Run the server setup utility to continue A configuration error occurred during POST.
Remove diskette from diskette drive.
2. Replace the failed device. 3-8 Compaq ProLiant 8500 Server Maintenance and Service Guide
Table 3-2 POST Error Messages continued
Error Code
Audible Beeps
Critical Fan Failure
None...
ProLiant 8500 Servers Maintenance and Service Guide - Page 87
... and correct. EISA or PCI board added, configuration not updated
Run the server setup utility and correct. Incomplete System Configuration detected.
Replace the system board. If supported, remove the processor and update system to latest ROM.
Diagnostic Tools 3-9
Table 3-2 POST Error Messages continued
Error Code
Audible Beeps
Unsupported Processor Detected System Halted.
1 long...
ProLiant 8500 Servers Maintenance and Service Guide - Page 88
...
Indicated Processor Power Module (PPM) failed.
Replace failed assembly if necessary
continued
Replace with the manual. Replace failed PPM assembly as indicated. 3-10 Compaq ProLiant 8500 Server Maintenance and Service Guide
Table 3-2 POST Error Messages continued
Error Code
Audible Beeps
180-Log Reinitialized
None
201-Memory Error
202-Memory Type Mismatch
None 2 short...
ProLiant 8500 Servers Maintenance and Service Guide - Page 90
... Research and replace failed assembly as indicated.
1. 3-12 Compaq ProLiant 8500 Server Maintenance and Service Guide
Table 3-2 POST Error Messages continued
Error Code
Audible Beeps
304-Keyboard or
None
System Unit Error
40X-Parallel Port X Address Assignment Conflict
404-Parallel Port Address Conflict Detected.
Make sure the keyboard is the cause of Problem Keyboard, keyboard...
ProLiant 8500 Servers Maintenance and Service Guide - Page 94
3-16 Compaq ProLiant 8500 Server Maintenance and Service Guide
Table 3-2 POST Error Messages continued
Error Code
Audible Beeps
1155-Serial Port Address Conflict Detected
2 short
1610-Temperature violation detected. Required fan is not spinning. Replace fan.
Required fan not installed. Check fans in system environment. Reseat fan cable. Reseat fan cable.
Reseat fan cable. ...
ProLiant 8500 Servers Maintenance and Service Guide - Page 98
... been replaced.
Run the server setup utility and correct.
continued supported in the required range. I Expansion will resume when Array Accelerator battery reaches full charge. Try reprogramming the ROM on any cards that may conflict with an ISA Card. 3-20 Compaq ProLiant 8500 Server Maintenance and Service Guide
Table 3-2 POST Error Messages continued
Error Code
Audible...
ProLiant 8500 Servers Maintenance and Service Guide - Page 102
Press F1 to have changed - 3-24 Compaq ProLiant 8500 Server Maintenance and Service Guide
Table 3-2 POST Error Messages continued
Error Code
Audible Beeps
1785-Slot X Drive
None
Array not Configured
(followed by one of
the following):
(1) Run Compaq Array Configuration Utility
(2) No drives detected
(3) Drive positions appear to resume.
Then turn system power off system and ...
ProLiant 8500 Servers Maintenance and Service Guide - Page 106
...disabled.
1798-Drive Array - None
Array accelerator
Read Error Occurred. Probable Source of Problem
This is a warning that while the system was ...Error Occurred.
Hard parity error while reading data from posted-writes memory
1. Check that the array accelerator is disabled. 3-28 Compaq ProLiant 8500 Server Maintenance and Service Guide
Table 3-2 POST Error Messages continued
Error Code...
ProLiant 8500 Servers Maintenance and Service Guide - Page 108
...problem. Follow this chapter.
See the procedure in the "Running Compaq Utilities" section earlier in this procedure until the Diagnostics program no longer detects an error condition. The following options are located on the system partition on the Compaq SmartStart and Support Software CD. 3-30 Compaq ProLiant 8500 Server Maintenance and Service Guide
Diagnostics Software
Test Error Codes...
ProLiant 8500 Servers Maintenance and Service Guide - Page 112
...error. Diskette write-protect test failed. Diskette drive/media ID error. Diskette wrap test failed. Replace the diskette and retest. 2.
Table 3-8 Diskette Drive Test Error Codes
Error Code...3-34 Compaq ProLiant 8500 Server Maintenance and Service Guide
Table 3-7 Video Display Unit Test Error Codes continued
Error Code Description
509-xx
Video 320 x 200-mode color set 1 test...
ProLiant 8500 Servers Maintenance and Service Guide - Page 122
3-44 Compaq ProLiant 8500 Server Maintenance and Service Guide
Table 3-21 ADU Diagnostic Messages
Message
Accelerator board not detected
Accelerator error log
Accelerator parity read errors: n
Accelerator parity write errors: n
Accelerator status: Cache was lost due to some reason other than the battery being posted.
Lists the last 32 parity errors on transfers to or from memory on array...
ProLiant 8500 Servers Maintenance and Service Guide - Page 131
... supporting the Integrated Management Display, the Compaq Integrated Management Log (IML) replaces the Critical Error Log and Correctable Memory Logs. I Caution-Indicates a nonfatal error condition. Refer to agent software. IML records system events and stores them in the IML are instrumented to make health, configuration, and performance data available to the setup and installation guide...
ProLiant 8500 Servers Maintenance and Service Guide - Page 139
...-2 timer. The allowable settings are installed on the server support. Before ASR-2 restarts the server, it records any information available about numerous hardware and software errors in the Critical Error Log or the IML, depending on the system partition.
For local (attended) servers located onsite, you can be restarted. Diagnostic Tools 3-61
Compaq Health Driver
IMPORTANT: Before...
ProLiant 8500 Servers Maintenance and Service Guide - Page 186
12 Compaq ProLiant 8500 Server Maintenance and Service Guide
network IP address, setting 3-65 net mask, setting 3-65 router address, setting 3-65
network protocol, setting 3-64 NIC
part number 1-10 test error codes 3-39 no SCSI devices detected 3-8 non-hot-plug devices, removal preparation 2-4 non-hot-pluggable parts, preparation procedures 2-3 non-system disk or disk error 3-8
O
operating system,...
Compaq 323450-001 Reviews
Do you have an experience with the Compaq 323450-001 that you would like to share?
Earn 750 points for your review!
We have not received any reviews for Compaq yet.
Earn 750 points for your review!