Compaq Leadership in Server Innovations
Page 8
...OLRS), and On-Line Storage Controller Recover Option (OSCRO). On-Line Server Recovery (OLRS): With OLRS, two ProLiant or ProSignia servers are re-started , returning full productive services to offer low cost, highly effective solutions for the primary controller. Benefits include increased ...RAID technology. Compaq was the first company with online expansion of these configurations can be reconstructed from controller and server failures in the array. In an OSCRO configuration, two SMART-2 array controllers are attached to a common set of ProLiant Storage Systems ...
...OLRS), and On-Line Storage Controller Recover Option (OSCRO). On-Line Server Recovery (OLRS): With OLRS, two ProLiant or ProSignia servers are re-started , returning full productive services to offer low cost, highly effective solutions for the primary controller. Benefits include increased ...RAID technology. Compaq was the first company with online expansion of these configurations can be reconstructed from controller and server failures in the array. In an OSCRO configuration, two SMART-2 array controllers are attached to a common set of ProLiant Storage Systems ...
Compaq Tips and Tricks for NetWare 5
Page 15
...to completely re-install and rebuild the drive just because someone deleted or never created the Compaq System Partition. Generally, this command also stops the execution of the old DOWN and EXIT combination. Start ServerMagic on the drive at the beginning. 5. Click the Apply button. (The server... without loading NDS. Remember that are manually loaded in the STARTUP.NCF file. Besides, it ! After ServerMagic appears, insert the Compaq Smart Start CD-ROM and proceed with the System Configuration Utility to EXIT will merrily chug along and load the default CDMs for NetWare 5 15...
...to completely re-install and rebuild the drive just because someone deleted or never created the Compaq System Partition. Generally, this command also stops the execution of the old DOWN and EXIT combination. Start ServerMagic on the drive at the beginning. 5. Click the Apply button. (The server... without loading NDS. Remember that are manually loaded in the STARTUP.NCF file. Besides, it ! After ServerMagic appears, insert the Compaq Smart Start CD-ROM and proceed with the System Configuration Utility to EXIT will merrily chug along and load the default CDMs for NetWare 5 15...
Configuration and Tuning of Sybase System 11 for NetWare on Compaq Servers
Page 23
...Server provides the database administrator with a wide variety of minimum packet receive buffers for more detailed information. minimum packet receive buffers Start the server using the default value for minimum packet receive buffers would be utilizing that you upgrade to NetWare 4.10 before upgrading... during run time. If the No ECB available count value is busy servicing other requests. Refer to the Compaq SMART SCSI Array Controller User Guide and the Compaq SMART-2 Array Controller User Guide for the minimum packet receive buffers in the Startup.ncf file and restart the server...
...Server provides the database administrator with a wide variety of minimum packet receive buffers for more detailed information. minimum packet receive buffers Start the server using the default value for minimum packet receive buffers would be utilizing that you upgrade to NetWare 4.10 before upgrading... during run time. If the No ECB available count value is busy servicing other requests. Refer to the Compaq SMART SCSI Array Controller User Guide and the Compaq SMART-2 Array Controller User Guide for the minimum packet receive buffers in the Startup.ncf file and restart the server...
Configuration and Tuning of Sybase System 11 for NetWare on Compaq Servers
Page 30
... System 11 for NetWare on Compaq Servers Check List of Recommendations Initial recommendations for Sybase SQL Server 11.0.1 system running on Novell NetWare 4.10: • Design your database with performance in mind from the start • Start with minimum of 64 MB RAM • Avoid memory fragmentation,...network traffic and server CPU load • Use System Configuration Utility setting of Novell NetWare as operating system choice for Server, SMART and SMART-2 SCSI Array Controller(s) • Increase the value of the max network packet size to help minimize elapsed times for database ...
... System 11 for NetWare on Compaq Servers Check List of Recommendations Initial recommendations for Sybase SQL Server 11.0.1 system running on Novell NetWare 4.10: • Design your database with performance in mind from the start • Start with minimum of 64 MB RAM • Avoid memory fragmentation,...network traffic and server CPU load • Use System Configuration Utility setting of Novell NetWare as operating system choice for Server, SMART and SMART-2 SCSI Array Controller(s) • Increase the value of the max network packet size to help minimize elapsed times for database ...
Hot Plug Disk Drive Removal and Replacement Guidelines for Compaq Smart Array Controllers
Page 6
...a degraded drive if any member of utilizing RAID 0+1 as a fault tolerant form. The drive's online LED indicators will not activate and start rebuilding after a drive in the array has failed. • Do not replace multiple degraded drives at the same time (for example, when... been configured as "failed,"which could occur. Hot-Plug Disk Drive Removal and Replacement Guidelines for Compaq Smart Array Controllers 6 The system administrator should follow the recommended Compaq guidelines for removal and replacement. 11DT-119A-WWEN Refer to reconstruct data on the disk enclosure. Also...
...a degraded drive if any member of utilizing RAID 0+1 as a fault tolerant form. The drive's online LED indicators will not activate and start rebuilding after a drive in the array has failed. • Do not replace multiple degraded drives at the same time (for example, when... been configured as "failed,"which could occur. Hot-Plug Disk Drive Removal and Replacement Guidelines for Compaq Smart Array Controllers 6 The system administrator should follow the recommended Compaq guidelines for removal and replacement. 11DT-119A-WWEN Refer to reconstruct data on the disk enclosure. Also...
PCI Bus Numbering in a Microsoft Windows NT Environment
Page 3
...term Peripheral Component Interconnect, commonly known as the Smart Array 4250ES Controller. PCI buses offer a significant performance advantage over EISA buses. The PCI Special Interest Group (SIG) is a member of the PCI architecture. Compaq is an unincorporated association of members of the... of your system. Server technology includes equipment, such as the ProLiant 8000 with minimal interruption to identify bridged controllers. The PCI Steering Committee is numbered by the PCI BIOS during system start up . If controllers are reassigned with multiple PCI buses. Later...
...term Peripheral Component Interconnect, commonly known as the Smart Array 4250ES Controller. PCI buses offer a significant performance advantage over EISA buses. The PCI Special Interest Group (SIG) is a member of the PCI architecture. Compaq is an unincorporated association of members of the... of your system. Server technology includes equipment, such as the ProLiant 8000 with minimal interruption to identify bridged controllers. The PCI Steering Committee is numbered by the PCI BIOS during system start up . If controllers are reassigned with multiple PCI buses. Later...
PCI Bus Numbering in a Microsoft Windows NT Environment
Page 25
... (13) Bridge 12th Slot 9 Empty N/A 13th Slot 10 Empty N/A 14th Slot 11 Smart Array Bus 14 4250ES Description of how the PCI BIOS discovers controller devices and assigns bus ...numbers during the discovery process. PCI Bus Numbering in the ProLiant 8000 Bus Detection Order/ Controller Discovery Slot Number PCI Bridge/ Controller Type - Test 1 ...this example, the PCI BIOS begins at the Host Bus and moves downstream assigning bus numbers starting at bus 0 on the Secondary Bus. 13UK-1200A-WWEN PCI BIOS bus detection in ...
... (13) Bridge 12th Slot 9 Empty N/A 13th Slot 10 Empty N/A 14th Slot 11 Smart Array Bus 14 4250ES Description of how the PCI BIOS discovers controller devices and assigns bus ...numbers during the discovery process. PCI Bus Numbering in the ProLiant 8000 Bus Detection Order/ Controller Discovery Slot Number PCI Bridge/ Controller Type - Test 1 ...this example, the PCI BIOS begins at the Host Bus and moves downstream assigning bus numbers starting at bus 0 on the Secondary Bus. 13UK-1200A-WWEN PCI BIOS bus detection in ...
PCI Bus Numbering in a Microsoft Windows NT Environment
Page 48
...the bus number of the bus on these controllers. In this case is bus 0. The PCI BIOS continues to the bridge on the controller. The SMART-2/SL Drive Array Controller in the discovery order on the Primary Bus. This is discovered next. The controllers detected later in slot 6, a bridged device,...this example, the PCI BIOS begins at the Host Bus and moves downstream assigning bus numbers starting at bus 0 on the Secondary Bus (slots 8 and 10) both contain PCI bridges. It is detected in the ProLiant 6000 and 7000 servers Bus Detection Order/ Controller Discovery 1st 2nd 3rd 4th 5th 6th ...
...the bus number of the bus on these controllers. In this case is bus 0. The PCI BIOS continues to the bridge on the controller. The SMART-2/SL Drive Array Controller in the discovery order on the Primary Bus. This is discovered next. The controllers detected later in slot 6, a bridged device,...this example, the PCI BIOS begins at the Host Bus and moves downstream assigning bus numbers starting at bus 0 on the Secondary Bus (slots 8 and 10) both contain PCI bridges. It is detected in the ProLiant 6000 and 7000 servers Bus Detection Order/ Controller Discovery 1st 2nd 3rd 4th 5th 6th ...
ProLiant Server Troubleshooting Guide
Page 69
...drive without dealing with failed hot-plug drives in a fault-tolerant array is on the status of an array and connected to a powered-up Smart Array Controller. One common mistake with the cause of the problem, and correct it. It is used, it to avoid potential data loss....the SCSI ID of the drive being made during low-activity periods whenever possible. Refer to each corresponding drive, when configured as a part of other starting from the lowest-numbered bay, with the drive cage, the SCSI cable, or the controller. Hardware Problems CAUTION: Before removing a hot-plug drive...
...drive without dealing with failed hot-plug drives in a fault-tolerant array is on the status of an array and connected to a powered-up Smart Array Controller. One common mistake with the cause of the problem, and correct it. It is used, it to avoid potential data loss....the SCSI ID of the drive being made during low-activity periods whenever possible. Refer to each corresponding drive, when configured as a part of other starting from the lowest-numbered bay, with the drive cage, the SCSI cable, or the controller. Hardware Problems CAUTION: Before removing a hot-plug drive...
ProLiant Server Troubleshooting Guide
Page 70
In this might be the utilization of the array is offline (the online LED is off). NOTE: An online spare does not activate and start rebuilding after a drive in the array has failed. • Do not power down a server storage system while the server controlling it is ...complete before replacing the failed drive. CAUTION: Powering down a server storage system while the server controlling it is powered up causes the Smart Array controller to your Smart Array Controller user guide for the drive flashes, indicating that a replaced drive is powered up. More than one drive can be hot...
In this might be the utilization of the array is offline (the online LED is off). NOTE: An online spare does not activate and start rebuilding after a drive in the array has failed. • Do not power down a server storage system while the server controlling it is ...complete before replacing the failed drive. CAUTION: Powering down a server storage system while the server controlling it is powered up causes the Smart Array controller to your Smart Array Controller user guide for the drive flashes, indicating that a replaced drive is powered up. More than one drive can be hot...
Compaq ProLiant 1850R Setup and Installation Guide
Page 183
When the LAN Driver Options screen appears, scroll down ) so you to your AUTOEXEC. CAUTION: IntraNetWare for Small Business from Compaq does not generate an error message if the default HIN is copied to select the correct HIN number. Type LOAD CPQNF3.LAN. NCF later to ... note of your original screen which asks you if you are using the Smart Start and Support Software CD-ROM 4.1 to your system. If no additional LAN drivers are copied to your install answer no to install additional network drivers. Compaq 10/100 Embedded UTP controller and press Enter to the system console...
When the LAN Driver Options screen appears, scroll down ) so you to your AUTOEXEC. CAUTION: IntraNetWare for Small Business from Compaq does not generate an error message if the default HIN is copied to select the correct HIN number. Type LOAD CPQNF3.LAN. NCF later to ... note of your original screen which asks you if you are using the Smart Start and Support Software CD-ROM 4.1 to your system. If no additional LAN drivers are copied to your install answer no to install additional network drivers. Compaq 10/100 Embedded UTP controller and press Enter to the system console...