Software Guide
Page 31
... these sections: • Catalyst 4000 Series Switches, page 1-1 • Catalyst 2948G Switch, page 1-2 • Catalyst 2980G Switch, page 1-3 • Supervisor Engine Software, page 1-3 Catalyst 4000 Series Switches Note For installation information and a complete description of media. Table 1-1 Catalyst 4000 Series and Catalyst 4500 Series Switches Product Number Catalyst 4000 Series WS-C4003 WS-C4006 Chassis Description Catalyst 4003 • Modular 3-slot chassis • Optional redundant...
... these sections: • Catalyst 4000 Series Switches, page 1-1 • Catalyst 2948G Switch, page 1-2 • Catalyst 2980G Switch, page 1-3 • Supervisor Engine Software, page 1-3 Catalyst 4000 Series Switches Note For installation information and a complete description of media. Table 1-1 Catalyst 4000 Series and Catalyst 4500 Series Switches Product Number Catalyst 4000 Series WS-C4003 WS-C4006 Chassis Description Catalyst 4003 • Modular 3-slot chassis • Optional redundant...
Software Guide
Page 32
Catalyst 2948G Switch Chapter 1 Product Overview Table 1-1 Catalyst 4000 Series and Catalyst 4500 Series Switches (continued) Product Number WS-C4912G Catalyst 4500 Series WS-C4503 WS-C4506 Chassis Description Catalyst 4912G • Fixed-configuration switch • 12-Gbps backplane • Optional redundant power supplies • 12 1000BASE-X (GBIC) Gigabit Ethernet ports Catalyst 4503 • Modular 3-slot chassis • 28-Gbps full duplex backplane...
Catalyst 2948G Switch Chapter 1 Product Overview Table 1-1 Catalyst 4000 Series and Catalyst 4500 Series Switches (continued) Product Number WS-C4912G Catalyst 4500 Series WS-C4503 WS-C4506 Chassis Description Catalyst 4912G • Fixed-configuration switch • 12-Gbps backplane • Optional redundant power supplies • 12 1000BASE-X (GBIC) Gigabit Ethernet ports Catalyst 4503 • Modular 3-slot chassis • 28-Gbps full duplex backplane...
Software Guide
Page 33
Table 1-3 Catalyst 2980G Switch Product Number WS-C2980G-A Chassis Description Catalyst 2980G • Fixed-configuration switch • 12-Gbps backplane • Optional redundant power supplies • Two 1000BASE-X (GBIC) Gigabit Ethernet ports • 80 10/100BASE-TX Fast Ethernet ports Supervisor ...
Table 1-3 Catalyst 2980G Switch Product Number WS-C2980G-A Chassis Description Catalyst 2980G • Fixed-configuration switch • 12-Gbps backplane • Optional redundant power supplies • Two 1000BASE-X (GBIC) Gigabit Ethernet ports • 80 10/100BASE-TX Fast Ethernet ports Supervisor ...
Software Guide
Page 76
...Cisco switches and those switches released by the spanning tree feature, the maximum supported number of channels is not configurable. You can configure both Fast and Gigabit EtherChannel bundles as trunk links. Due to the port ID handling by licensed vendors. Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches...Frame Distribution EtherChannel distributes frames across the ports in an EtherChannel bundle do not have to the remaining ports within the EtherChannel. Hardware Support for a 6-slot chassis. You can enter the show port capabilities command to determine whether...
...Cisco switches and those switches released by the spanning tree feature, the maximum supported number of channels is not configurable. You can configure both Fast and Gigabit EtherChannel bundles as trunk links. Due to the port ID handling by licensed vendors. Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches...Frame Distribution EtherChannel distributes frames across the ports in an EtherChannel bundle do not have to the remaining ports within the EtherChannel. Hardware Support for a 6-slot chassis. You can enter the show port capabilities command to determine whether...
Software Guide
Page 110
...1Q. The network designates a new root switch; This extension provides for data traffic and enables load balancing. Therefore, MST requires that is added to consider: • The Catalyst 4006 switch is not a root switch In this switch cannot become the root switch. Interconnected bridges that have compatible VLAN-instance... that you replace the chassis with MAC reduction enabled and its default spanning tree bridge ID priority set of bridges with 802.1D STP, 802.1w, the Rapid Spanning Tree Protocol (RSTP), and the Cisco PVST+ architecture. If the switch is in one instance ...
...1Q. The network designates a new root switch; This extension provides for data traffic and enables load balancing. Therefore, MST requires that is added to consider: • The Catalyst 4006 switch is not a root switch In this switch cannot become the root switch. Interconnected bridges that have compatible VLAN-instance... that you replace the chassis with MAC reduction enabled and its default spanning tree bridge ID priority set of bridges with 802.1D STP, 802.1w, the Rapid Spanning Tree Protocol (RSTP), and the Cisco PVST+ architecture. If the switch is in one instance ...
Software Guide
Page 375
... receiver added. Console> (enable) set snmp community read -write SNMP trap receiver added. set snmp trap 172.16.10.10 read -write-all | auth | bridge | chassis | config | entity | entityfru | envfan | envpower | envshutdown | envtemp | flashinsert | flashremove | ippermit | module | stpx | syslog | system | vlancreate | vlandelete | vmps | vtp] ...: Step 1 Step 2 Step 3 Step 4 Task Command Define the SNMP community strings for the community string). 78-15486-01 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 24-7
... receiver added. Console> (enable) set snmp community read -write SNMP trap receiver added. set snmp trap 172.16.10.10 read -write-all | auth | bridge | chassis | config | entity | entityfru | envfan | envpower | envshutdown | envtemp | flashinsert | flashremove | ippermit | module | stpx | syslog | system | vlancreate | vlandelete | vmps | vtp] ...: Step 1 Step 2 Step 3 Step 4 Task Command Define the SNMP community strings for the community string). 78-15486-01 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 24-7
Software Guide
Page 388
...Chassis,Bridge,Repeater,Vtp,Auth,ippermit,Vmps,config,entity,stpx Port Traps Enabled: 1/1-2,4/1-48,5/1 Community-Access Community-String read-only Everyone read-write Administrators read-write-all Root Trap-Rec-Address Trap-Rec-Community 172.16.10.10 read-write 172.16.10.20 read-write-all Console> (enable) Viewing RMON Data... Access to RMON data is enabled. You cannot access RMON data through the switch CLI; however, CLI show snmp This example shows how to enable RMON and how to the Catalyst 4500 Series, Catalyst 2948G, and Catalyst 2980G Switches ...
...Chassis,Bridge,Repeater,Vtp,Auth,ippermit,Vmps,config,entity,stpx Port Traps Enabled: 1/1-2,4/1-48,5/1 Community-Access Community-String read-only Everyone read-write Administrators read-write-all Root Trap-Rec-Address Trap-Rec-Community 172.16.10.10 read-write 172.16.10.20 read-write-all Console> (enable) Viewing RMON Data... Access to RMON data is enabled. You cannot access RMON data through the switch CLI; however, CLI show snmp This example shows how to enable RMON and how to the Catalyst 4500 Series, Catalyst 2948G, and Catalyst 2980G Switches ...
Software Guide
Page 412
Setting the System Clock Chapter 27 Administering the Switch disable 9600 0% 0% Wed Apr 24 2002, 15:46:01 Power Capacity of the Chassis:2 supplies WARNING:Power supplies of -the-day (MOTD) banner that appears on configuring NTP, see Chapter 39, "Configuring NTP... the motd keyword is used to the switch. Display the login banner by logging out and logging back in privileged mode: Step 1 Step 2 Task Set the system clock. To set banner motd c message_of_the_day c - 27-4 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 78-15486...
Setting the System Clock Chapter 27 Administering the Switch disable 9600 0% 0% Wed Apr 24 2002, 15:46:01 Power Capacity of the Chassis:2 supplies WARNING:Power supplies of -the-day (MOTD) banner that appears on configuring NTP, see Chapter 39, "Configuring NTP... the motd keyword is used to the switch. Display the login banner by logging out and logging back in privileged mode: Step 1 Step 2 Task Set the system clock. To set banner motd c message_of_the_day c - 27-4 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 78-15486...
Software Guide
Page 423
... different types or wattages in your switch, the switch uses the power supply in power supply bay 1 (PS1) and ignores the power supply in a Catalyst 4500 series switch are less than the maximum available power for the chassis and inline power for the power ...; See Table 28-1 on page 28-4 for a list of the maximum available power for chassis and inline power for each power supply. 78-15486-01 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 28-3 Variable power supplies automatically adjust the power resources to combined mode...
... different types or wattages in your switch, the switch uses the power supply in power supply bay 1 (PS1) and ignores the power supply in a Catalyst 4500 series switch are less than the maximum available power for the chassis and inline power for the power ...; See Table 28-1 on page 28-4 for a list of the maximum available power for chassis and inline power for each power supply. 78-15486-01 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 28-3 Variable power supplies automatically adjust the power resources to combined mode...
Software Guide
Page 424
... Inline (min) = 433 Inline (max) = 1333 1400 W DC3 Chassis (min) = 200 Chassis + inline + backplane < 2166 N/A Chassis (max) = 1360 Inline (max)4 = (DC input5 − [Chassis (min) + backplane] / 0.75) * 0.96 2800 W AC Chassis = 1360 Chassis = 2473 In-line = 1400 Inline = 2545 1. The chassis power includes power for the Catalyst 4500 series switches. The inline power has 0.96 efficiency. 5. Power Management Limitations...
... Inline (min) = 433 Inline (max) = 1333 1400 W DC3 Chassis (min) = 200 Chassis + inline + backplane < 2166 N/A Chassis (max) = 1360 Inline (max)4 = (DC input5 − [Chassis (min) + backplane] / 0.75) * 0.96 2800 W AC Chassis = 1360 Chassis = 2473 In-line = 1400 Inline = 2545 1. The chassis power includes power for the Catalyst 4500 series switches. The inline power has 0.96 efficiency. 5. Power Management Limitations...
Software Guide
Page 425
... configuration so that the power requirements exceed the available power, when you power on the switch again, one or more information, refer to the Catalyst 4500 Series, Catalyst 2948G, and Catalyst 2980G Switches Command Reference. • Software automatically adjusts between system power (for modules, backplane, and... the power to the devices is installed in the chassis. 1400 W DC Power Supply Guidelines and Restrictions This section describes the guidelines and restrictions for using a 1400 W DC power supply in the Catalyst 4500 series switches: Caution Do not use the 1400 W DC power...
... configuration so that the power requirements exceed the available power, when you power on the switch again, one or more information, refer to the Catalyst 4500 Series, Catalyst 2948G, and Catalyst 2980G Switches Command Reference. • Software automatically adjusts between system power (for modules, backplane, and... the power to the devices is installed in the chassis. 1400 W DC Power Supply Guidelines and Restrictions This section describes the guidelines and restrictions for using a 1400 W DC power supply in the Catalyst 4500 series switches: Caution Do not use the 1400 W DC power...
Software Guide
Page 426
...the total module power usage does not exceed the absolute maximum power usage for the Catalyst 4000 series switches support a limited module configuration on a reduced number of the chassis empty. The total load for the modules, the supervisor engine, and the fan cannot.... You may consist of available power. 28-6 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 78-15486-01 An attempt to use the 1+1 redundancy mode in these hardware configurations: • One Catalyst 4006 chassis with a WS-X4013 supervisor engine with two 400...
...the total module power usage does not exceed the absolute maximum power usage for the Catalyst 4000 series switches support a limited module configuration on a reduced number of the chassis empty. The total load for the modules, the supervisor engine, and the fan cannot.... You may consist of available power. 28-6 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 78-15486-01 An attempt to use the 1+1 redundancy mode in these hardware configurations: • One Catalyst 4006 chassis with a WS-X4013 supervisor engine with two 400...
Software Guide
Page 427
...28-9 for each module in the chassis; however, the module is not shown in the chassis than a single power supply can handle, the switch displays this message: Insufficient power supplies for the Catalyst 4006 switch. An incorrect configuration will disrupt your chassis. Enter the set power budget ... placed into reset mode and displays this power supply cooling capacity restriction applies to the Catalyst 4006 switch. • When considering the 1+1 redundancy mode, you power down a chassis that require more power than is the power of your system during the evaluation cycle....
...28-9 for each module in the chassis; however, the module is not shown in the chassis than a single power supply can handle, the switch displays this message: Insufficient power supplies for the Catalyst 4006 switch. An incorrect configuration will disrupt your chassis. Enter the set power budget ... placed into reset mode and displays this power supply cooling capacity restriction applies to the Catalyst 4006 switch. • When considering the 1+1 redundancy mode, you power down a chassis that require more power than is the power of your system during the evaluation cycle....
Software Guide
Page 428
... WS-X4148-RJ modules-65 W each (600 W total) • Fan tray-25 W 28-8 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 78-15486-01 If you use the available 650 W. If you configure the chassis correctly, the switch does not enter the evaluation cycle. If the 400 W power supply fails, the backup...
... WS-X4148-RJ modules-65 W each (600 W total) • Fan tray-25 W 28-8 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 78-15486-01 If you use the available 650 W. If you configure the chassis correctly, the switch does not enter the evaluation cycle. If the 400 W power supply fails, the backup...
Software Guide
Page 430
... address reduction may or may change. If you migrate a Supervisor Engine II from a Catalyst 4006 switch to a Catalyst 4503 or 4506 switch, save your supervisor engine. The bridge ID priority of the new switch becomes the bridge ID priority that you replace the chassis with MAC reduction enabled and a default spanning tree bridge ID priority set to...
... address reduction may or may change. If you migrate a Supervisor Engine II from a Catalyst 4006 switch to a Catalyst 4503 or 4506 switch, save your supervisor engine. The bridge ID priority of the new switch becomes the bridge ID priority that you replace the chassis with MAC reduction enabled and a default spanning tree bridge ID priority set to...
Software Guide
Page 431
... and you can utilize inline power. An access point or IP phone is 100 percent efficient. Table 28-3 Switch Components Supporting Inline Power Switch Chassis Catalyst 4006 Catalyst 4503 Catalyst 4506 Modules WS-X4148-RJ45V WS-X4148-RJ45V Power Supplies Catalyst 4000 Series Power Entry Module (PEM) 1300 W AC 2800 W AC 1400 W DC You can supply a maximum of...
... and you can utilize inline power. An access point or IP phone is 100 percent efficient. Table 28-3 Switch Components Supporting Inline Power Switch Chassis Catalyst 4006 Catalyst 4503 Catalyst 4506 Modules WS-X4148-RJ45V WS-X4148-RJ45V Power Supplies Catalyst 4000 Series Power Entry Module (PEM) 1300 W AC 2800 W AC 1400 W DC You can supply a maximum of...
Software Guide
Page 437
... PWR-C45-2800AC PWR-C45-1000AC Modem Baud Traffic Peak Peak-Time disable 9600 0% 0% Fri May 31 2002, 10:24:04 Power Capacity of the Chassis: 1 supply 78-15486-01 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 28-17
... PWR-C45-2800AC PWR-C45-1000AC Modem Baud Traffic Peak Peak-Time disable 9600 0% 0% Fri May 31 2002, 10:24:04 Power Capacity of the Chassis: 1 supply 78-15486-01 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 28-17
Software Guide
Page 441
... Components Supporting Inline Power Switch Chassis Catalyst 4006 Catalyst 4503 Catalyst 4506 Modules WS-X4148-RJ45V1 WS-X4148-RJ45V Power Supplies Catalyst 4000 Family Power Entry Module (PEM) 1300 W AC 2800 W AC 1400 W DC 1. Configuring VoIP 29 C H A P T E R This chapter describes how to configure Voice-over-IP (VoIP) for IEEE 802.3af compliance • Cisco CallManager release 3.0 or later...
... Components Supporting Inline Power Switch Chassis Catalyst 4006 Catalyst 4503 Catalyst 4506 Modules WS-X4148-RJ45V1 WS-X4148-RJ45V Power Supplies Catalyst 4000 Family Power Entry Module (PEM) 1300 W AC 2800 W AC 1400 W DC 1. Configuring VoIP 29 C H A P T E R This chapter describes how to configure Voice-over-IP (VoIP) for IEEE 802.3af compliance • Cisco CallManager release 3.0 or later...
Software Guide
Page 555
... internal link between modules installed in the chassis. • SE3 handles traffic for Gigabit Ethernet uplink port 1/2 and traffic between SE1 and SE3. 78-15486-01 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 36-1 This chapter refers to the Catalyst 4500 Series, Catalyst 2948G, and Catalyst 2980G Switches Command Reference. As a result, traffic coming...
... internal link between modules installed in the chassis. • SE3 handles traffic for Gigabit Ethernet uplink port 1/2 and traffic between SE1 and SE3. 78-15486-01 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 36-1 This chapter refers to the Catalyst 4500 Series, Catalyst 2948G, and Catalyst 2980G Switches Command Reference. As a result, traffic coming...