Use and Care
Page 10
... Method: ■ Glass cleaner, mild liquid cleaner or nonabrasive scrubbing pad: Gently clean around the model and serial number plate because scrubbing may remove numbers. ■ All-Purpose Appliance Cleaner Part Number ...apply a cool damp cloth to the inner door glass before going into a dishwasher. ■ Gas Grate and Drip Pan Cleaner Part Number 31617: See "Assistance or Service" section to order. To...not bang grates and caps against each other or hard surfaces such as the entire range is completely cool. Cooked-on cleaning products. Before cleaning, make sure the oven ...
... Method: ■ Glass cleaner, mild liquid cleaner or nonabrasive scrubbing pad: Gently clean around the model and serial number plate because scrubbing may remove numbers. ■ All-Purpose Appliance Cleaner Part Number ...apply a cool damp cloth to the inner door glass before going into a dishwasher. ■ Gas Grate and Drip Pan Cleaner Part Number 31617: See "Assistance or Service" section to order. To...not bang grates and caps against each other or hard surfaces such as the entire range is completely cool. Cooked-on cleaning products. Before cleaning, make sure the oven ...
Use and Care
Page 12
...glass. ■ A whooshing or poof sound is heard when the Bake or Broil burner ignites. ■ On some models, a clicking sound can be heard when the gas valve is opening or cycling on and will make a single pop when it snaps open from the solenoid. It sounds similar... WARNING Electrical Shock Hazard Plug into a grounded 3 prong outlet. ■ Has a household fuse blown, or has a circuit breaker tripped? Oven will operate Gas range noises during the cycle. ■ A pop can result in death, fire, or electrical shock. ■ Is the power supply cord unplugged? Contact a ...
...glass. ■ A whooshing or poof sound is heard when the Bake or Broil burner ignites. ■ On some models, a clicking sound can be heard when the gas valve is opening or cycling on and will make a single pop when it snaps open from the solenoid. It sounds similar... WARNING Electrical Shock Hazard Plug into a grounded 3 prong outlet. ■ Has a household fuse blown, or has a circuit breaker tripped? Oven will operate Gas range noises during the cycle. ■ A pop can result in death, fire, or electrical shock. ■ Is the power supply cord unplugged? Contact a ...
Dimension Guide
Page 1
... to side wall or other combustible material For minimum clearance to the rigid gas supply line. W10130752 7-01-09 Ref. ® Freestanding Gas Range PRODUCT MODEL NUMBERS AGR3311WD OVERALL DIMENSIONS Gas supply: Use 3/4" (1.9 cm) rigid pipe gas supply line to change without notice. gas, piping or tubing size can be 1/2" (1.3 cm) minimum. NOTE: 24" (61 cm) minimum...
... to side wall or other combustible material For minimum clearance to the rigid gas supply line. W10130752 7-01-09 Ref. ® Freestanding Gas Range PRODUCT MODEL NUMBERS AGR3311WD OVERALL DIMENSIONS Gas supply: Use 3/4" (1.9 cm) rigid pipe gas supply line to change without notice. gas, piping or tubing size can be 1/2" (1.3 cm) minimum. NOTE: 24" (61 cm) minimum...
Installation Instruction
Page 3
...children and adults. See "Electrical Requirements" and "Gas Supply Requirements" sections. Model/serial rating plate location ■ The range should be available. If cabinet storage is moved. See "Electrical Requirements" section. ■ Proper gas supply connection must provide complete enclosure of the sides ...masonry drill bit (for convenient use in the wall or floor where range is located on the model/serial rating plate. This oven has been designed in death or serious burns to LP gas ■ Noncorrosive leak-detection solution Parts supplied Check that the materials ...
...children and adults. See "Electrical Requirements" and "Gas Supply Requirements" sections. Model/serial rating plate location ■ The range should be available. If cabinet storage is moved. See "Electrical Requirements" section. ■ Proper gas supply connection must provide complete enclosure of the sides ...masonry drill bit (for convenient use in the wall or floor where range is located on the model/serial rating plate. This oven has been designed in death or serious burns to LP gas ■ Noncorrosive leak-detection solution Parts supplied Check that the materials ...
Installation Instruction
Page 5
... the control panel to the manufacturer's instructions. NOTE: The metal chassis of the range must be conducted according to work. IMPORTANT: This installation must be obtained from the gas specified on the model/serial rating plate for use with the National Electrical Code, ANSI/NFPA 70 or... Canadian Electrical Code, CSA C22.1. IMPORTANT: Leak testing of the range must be used , it is required. The model/serial rating plate located behind ...
... the control panel to the manufacturer's instructions. NOTE: The metal chassis of the range must be conducted according to work. IMPORTANT: This installation must be obtained from the gas specified on the model/serial rating plate for use with the National Electrical Code, ANSI/NFPA 70 or... Canadian Electrical Code, CSA C22.1. IMPORTANT: Leak testing of the range must be used , it is required. The model/serial rating plate located behind ...
Installation Instruction
Page 6
...of 4% for each 1,000 ft (304.8 m) above the manifold pressure shown on the model/serial rating plate are reduced at least 1" water column pressure above sea level (not applicable for connecting range to the gas supply line. ■ A ½" (1.3 cm) male pipe thread is a registered ...trademark of LP gas must be isolated from the gas supply piping system by closing . A smaller size pipe on or shutting off gas to the range. This valve should be used in the system. Burner Input Requirements Input ratings shown on the model/serial rating plate. Rigid...
...of 4% for each 1,000 ft (304.8 m) above the manifold pressure shown on the model/serial rating plate are reduced at least 1" water column pressure above sea level (not applicable for connecting range to the gas supply line. ■ A ½" (1.3 cm) male pipe thread is a registered ...trademark of LP gas must be isolated from the gas supply piping system by closing . A smaller size pipe on or shutting off gas to the range. This valve should be used in the system. Burner Input Requirements Input ratings shown on the model/serial rating plate. Rigid...
Installation Instruction
Page 13
...burner: Std burner 88 Super burner 96 Std burner 88 Std burner 88 A. IMPORTANT: Do not overtighten. A B For models with 4 standard burners: A B A. Remove Natural gas orifice spuds using a 7 mm combination wrench. 5. The orifice spud is behind the oven burner air shutter. Spud size... the Natural gas orifice spud. 5. Install the number "56" LP gas spud. Place Natural gas oven burner spud in the package containing literature supplied with "56" 6. Install LP gas orifice spuds using a 7 mm combination wrench. 4. LP oven orifice spud stamped with the range. 4. Reinstall...
...burner: Std burner 88 Super burner 96 Std burner 88 Std burner 88 A. IMPORTANT: Do not overtighten. A B For models with 4 standard burners: A B A. Remove Natural gas orifice spuds using a 7 mm combination wrench. 5. The orifice spud is behind the oven burner air shutter. Spud size... the Natural gas orifice spud. 5. Install the number "56" LP gas spud. Place Natural gas oven burner spud in the package containing literature supplied with "56" 6. Install LP gas orifice spuds using a 7 mm combination wrench. 4. LP oven orifice spud stamped with the range. 4. Reinstall...
Installation Instruction
Page 15
... spud stamped "47" in the "Electronic Ignition System" section for properly connecting the range to complete this procedure. 15 A Std Burner 149 Std Burner 149 Std Burner 149 Std Burner 149 For models with the range. 4. Complete Conversion 1. Natural gas flames do not have a very distinct blue flame ¼" to ½" (0.64 cm to...
... spud stamped "47" in the "Electronic Ignition System" section for properly connecting the range to complete this procedure. 15 A Std Burner 149 Std Burner 149 Std Burner 149 Std Burner 149 For models with the range. 4. Complete Conversion 1. Natural gas flames do not have a very distinct blue flame ¼" to ½" (0.64 cm to...