User Guide
Page 87
...the child task indicates 0 percent to the log file. When you use record mode to record a controller's configuration and you specify a log file (/L switch), the ACU writes build/verify and clear status information about each array in the configuration to 100 percent. When a clear task ... array information ...Passed Scanning for Drives ...Passed Reading cache values...Passed Array #0 Status : OK Array #1 Status : BUILD/VERIFY 30% Array #2 Status : BUILD/VERIFY/CLEAR FAILED Each status line consists of the prefix: Array# Status : where is an integer between 0 and 99, inclusive.
...the child task indicates 0 percent to the log file. When you use record mode to record a controller's configuration and you specify a log file (/L switch), the ACU writes build/verify and clear status information about each array in the configuration to 100 percent. When a clear task ... array information ...Passed Scanning for Drives ...Passed Reading cache values...Passed Array #0 Status : OK Array #1 Status : BUILD/VERIFY 30% Array #2 Status : BUILD/VERIFY/CLEAR FAILED Each status line consists of the prefix: Array# Status : where is an integer between 0 and 99, inclusive.
User Guide
Page 97
...allowed for this array. Build/Verify/Clear failed-The build/verify or clear running on one or more arrays has failed. Unable to initialize drive-The ACU was unable to run the application-There is invalid or out-of-range. Controller not responding-The controller has stopped responding to run the...ACU exited with no errors (success) and you specified is not enough memory to initialize one or more devices. B-33 Incorrect controller number-The controller number you must restart the computer. Insufficient memory to the ACU. DOS Utilities Code 9 10 11 12 13 14 15 16...
...allowed for this array. Build/Verify/Clear failed-The build/verify or clear running on one or more arrays has failed. Unable to initialize drive-The ACU was unable to run the application-There is invalid or out-of-range. Controller not responding-The controller has stopped responding to run the...ACU exited with no errors (success) and you specified is not enough memory to initialize one or more devices. B-33 Incorrect controller number-The controller number you must restart the computer. Insufficient memory to the ACU. DOS Utilities Code 9 10 11 12 13 14 15 16...
User Guide
Page 107
... use the automatic failover commands that enable you to verify that reside in its place. In the following example: AAC0> controller set automatic_failover /failover_enabled=TRUE Executing: controller set automatic_failover /failover_enabled=TRUE After running the controller set global_failover commands. C-8 I Display a controller's automatic failover status. AAC0> controller show automatic_failover Executing: controller show automatic_failover Automatic failover DISABLED Enabling Automatic Failover...
... use the automatic failover commands that enable you to verify that reside in its place. In the following example: AAC0> controller set automatic_failover /failover_enabled=TRUE Executing: controller set automatic_failover /failover_enabled=TRUE After running the controller set global_failover commands. C-8 I Display a controller's automatic failover status. AAC0> controller show automatic_failover Executing: controller show automatic_failover Automatic failover DISABLED Enabling Automatic Failover...