Chronotherm T8090a Heat Only
I have 4 wires at the t-stat ....blue,red,white & off white. i have terminals c ,w, and c. At on...
(Posted by falcn0413 3 years ago)
Want To Replace An Old Honeywell Thermostat Model With A Newer Updated Model.
I want to replace a manual Honeywell Chronotherm Thermostat with an updated digital type. The model ...
(Posted by Wjvivola 3 years ago)
Digital Replacement For T8090a?
Is there Honeywell digital replacement for T8090A? Steam boiler
(Posted by bipcar 12 years ago)

Popular Honeywell T8090A Manual Pages

Owner's Manual - Page 1

Heating or Cooling Thermostat and Wallplate or Heating/Cooling Thermostat and Subbase T8090A/191108A, Q682B OWNER'S MANUAL 1 696-095-07547-4-22
Owner's Manual - Page 2

... your new Honeywell fuel saver thermostat. The Honeywell name is replacing a control that contains mercury in the trash. at the end of an old control containing mercury in the trash at 1-800-468-1502. 69-0574-2 2 Welcome to the world of energy savings with your assurance of accurate control and reliable operation for instructions regarding...
Owner's Manual - Page 3

TABLE OF CONTENTS Features Of Your Thermostat ...4 Setting The Temperature ...7 Inserting Clock Batteries ...8 Setting The Clock ...9 Programming ...10 Troubleshooting ...14 Servicing The Thermostat ...23 Cycle Rate Adjustment ...23 Thermometer Adjustment ...24 Warranty ...27 3 69-0574-2
Owner's Manual - Page 4

... minute hand clock- Controls high and low temperature at specific time of day as set clock for 24-hour dial. 7 PROGRAM INDEX WHEEL. Left (blue mark) controls the low temperature, right (red mark) controls the high temperature. 1 2 3 M8726 69-0574-2 4 Features Of Your Thermostat 1 FLIP-UP COVER. wise to match the correct AM...
Owner's Manual - Page 5

Must be inserted into 24-hour clock dial slots to energy savings setting and vice versa without changing the program. 12 HEAT ANTICIPATOR SCALEPLATE. Calibrated to match the heating ... or cooling system on 24-hour dial at 10-minute intervals for program pin insertion. 11 MANUAL PROGRAM ADVANCE BUTTON. Must be adjusted to match the heating system current draw in amperes. 13 ANTICIPATOR...
Owner's Manual - Page 10

... be inserted at 10:00 PM for each energy saving period. 24-HOUR PROGRAM DIAL (GRAY AREA FOR NIGHT SETTINGS) FLIP-UP COVER PROGRAM PINS THERMOSTAT COVER PROGRAM PIN SLOT PROGRAM INDEX WHEEL MANUAL PROGRAM ADVANCE BUTTON PROGRAM PIN STORAGE TIME INDICATOR ARROW M8692 Fig. 4-Program components. 69-0574-2 10 The red pins...
Owner's Manual - Page 13

Start Or End Programs With Manual Program Advance Button IMPORTANT:To prevent damage to the normal setting. After pressing the button, check the program indicator to accommodate temporary ...program change. if it shows red, the higher temperature is in effect; The manual program advance button enables immediate, one-time-only program changes to ensure the system is in effect. Using the...
Owner's Manual - Page 14

...Problem No heat. 69-0574-2 Check Action - If blown or tripped, replace fuse or reset breaker. - Move switch to furnace. pilot flame. R and W thermostat connections. other problem. Contact a qualified service... per furnace manufacturers instructions. - Repair any frayed or broken wires. Turn Off power to ON. - Troubleshooting Your Honeywell thermostat requires little or ...
Owner's Manual - Page 15

...0574-2 positions of subbase system switch. Rooms do not warm - Move to desired settings. up at the wrong locations. programs pins for heating system. position of thermostat setpoint are not correct. Action Turn timer ahead 12 hours. levers. - Troubleshooting (continued) Problem Check Energy savings - program dial for proper day or temperature program night phase...
Owner's Manual - Page 16

Troubleshooting (continued) Problem Room temperatures are not correct (continued). Check - Action HEATING-ONLY SYSTEM-Move temperature setting levers 5°F (3°C) above room temperature. Cooling system should start. If the system does not operate, call a qualified technician. Heating system should start . (continued) 69-0574-2 16 thermostat circuits. HEATING/...
Owner's Manual - Page 17

anticipator setting. (See figure on page 23 for anticipator location.) - Cooling system should start. Troubleshooting (continued) Problem Room Temperatures are not correct (continued). No cooling. 1 Check - May be in OFF or HEAT position. - If the systems do not operate, call a qualified technician. Observe burner operation. If fuse is blown or breaker tripped, replace or reset...
Owner's Manual - Page 18

...) 69-0574-2 18 Contact qualified service technician for assistance. - condenser switch position. Repair any frayed or broken wires. Contact a qualified service technician for change of thermostat. Check Action - for drafts or radiant heat. other. Troubleshooting (continued) Problem No cooling 1 (continued) Thermostat setting and thermometer reading disagree. Located...
Owner's Manual - Page 19

if new batteries are installed and clock still does not run . Install as shown on page 22 for cause and reaction. (continued) 69-0574-2 Replace thermostat. Troubleshooting (continued) Problem Thermostat setting and thermometer reading disagree (continued). calibration of thermometer. - Refer to run. 3 Batteries may need replacement - If no connections, clock needs batteries in ...
Owner's Manual - Page 21

...-only system. 2 Not applicable on page 8. Action Replace with two new AAA alkaline batteries as shown on model used in cooling-only system. 3 If clock is not battery powered, clock may need replacement. If this Troubleshooting section has not solved the problem, call your qualified heating service technician or Honeywell Customer Assistance Center, 1-800-468-1502, Monday...
Owner's Manual - Page 23

ANTICIPATOR SCALEPLATE ANTICIPATOR SETTING LEVER M7317 Fig. 6-Heat anticipator setting. 23 69-0574-2 If the thermostat seems to the temperature lever settings. NOTE: Most hot water systems require a setting of 1.2A. Servicing The Thermostat Cycle Rate Adjustment The equipment should cycle on and off just enough to keep the room temperature close to cycle the heating system too...

Honeywell T8090A Reviews

Do you have an experience with the Honeywell T8090A that you would like to share?
Earn 750 points for your review!
We have not received any reviews for Honeywell yet.

Popular Honeywell T8090A Search Terms

The following terms are frequently used to search for Honeywell T8090A support:

Ask a New Question
Use the box below to post a new question about Honeywell T8090A.
Manuals / Documents
Download any of our Honeywell T8090A manuals for free!

We have the following 1 documents available for the Honeywell T8090A:
  • Owner's Manual

Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Honeywell Manuals

Find free Honeywell T8090A manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Honeywell Reviews

View thousands of Honeywell T8090A user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Honeywell customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Honeywell customer service rankings, employee comments and much more from our sister site.

Honeywell Recalls

Find comprehensive Honeywell recall information updated hourly on RecallOwl.com.