Honeywell MK9535-79A540 - MS9535 VoyagerBT - Wireless Portable Barcode Scanner Support and Manuals

Get Help and Manuals for this Honeywell item

View All Support Options Below
Free Honeywell MK9535-79A540 manuals!
Problems with Honeywell MK9535-79A540?

Ask a Question

Most Recent Honeywell MK9535-79A540 Questions

No Match For Failure Mode Indicator
For MS9535 Voyager BT I have the following: Flashing blue light with TWO razzberry tones I do not ...
(Posted by libtech 12 years ago)

Popular Honeywell MK9535-79A540 Manual Pages

User Guide - Page 14

... recycle program for batteries as directed by the governing agency for Lithium Batteries: • Do not place batteries in fire or heat the batteries • Do not store batteries near fire or other with the same or equivalent type recommended by the manufacture. CHARGING THE SCANNER (CONTINUED) Safety Precautions for the country where the batteries are incorrectly replaced.
User Guide - Page 29

... range from cradle to recharge the battery. Contact a Metrologic representative at power up Contact a Metrologic Representative, if the unit will not hold the programmed configuration. Continuous razz tone on power up Possible ROM failure Flash ROM Upgrade Required Non-volatile RAM failure Contact a Metrologic Representative, if the unit will not function. TROUBLESHOOTING GUIDE...
User Guide - Page 30

... the bar code that the scanner is connected to econo mode or high speed. 26 The unit scans, but does not scan/or beep Beeper disabled. i.e. The unit scans a bar code, but locks up , but the data transmitted to support some bar codes and NOT for a longer time. The type of printer could be the problem. TROUBLESHOOTING GUIDE (CONTINUED) Symptoms Unit scans, Communicates...
Configuration Guide - Page 7

...systems have unique formats and protocol requirements, Honeywell provides a wide range of configurable features that is a factory default. Power-up the scanner. 2. Enter/Exit Configuration Mode ³ 999999 1-1 NOVRAM saves the settings when the power is off the scanner before scanning the enter/exit configuration mode bar code. 4. Bar codes marked with a tilde ( ~ ) requires the Multi...
Configuration Guide - Page 11

... Service Library Code 39 2-3 Code 39 bar codes are converted to PARAF format. * Disable PARAF Support * Allow PARAF Codes Only Allow Non-PARAF Codes Enable TRI-OPTIC Code * Disable TRI-OPTIC Code * Use Standard Code 39 Framing Try Code 39 Codes Without 5 Bar Multiples Enable ITF/Code 39 Filters * Disable ITF/Code 39 Filters Enable Self-Service Library Code 39 * Disable Self-Service Library Code...
Configuration Guide - Page 80

... 117803 15-2 Enable Uni-Directional USB Serial Emulation Mode -Supported in the Honeywell Focus® area-imaging products. Enable Bar Code ID Disable Bar Code ID Enable USB Reserve Code #1 Disable USB Reserve Code #1 Enable USB Reserve Code #2 Disable USB Reserve Code #2 Sears USB Defaults Sears Aux Defaults Enable IBM 1520 Code Flag Emulation - Note: This bar code enables Bi-Directional...
Configuration Guide - Page 95

...19 MS9535 VoyagerBT® The MS9535 can initiate a connection to the scanner. The scanner will go into service mode. When scanned this mode, other devices equipped with a FNC3 (e.g., 000CA700118) the user must also be scanned to other Bluetooth wireless technology enabled devices can act as the PIN ID. In this feature enables the scanner to store the next scanned bar code as...
Configuration Guide - Page 96

...* Disable Range Gate Enable BT Test - Activates an audible indicator the when the scanner is not making contact via the battery terminal contacts. * Disable In Stand Error Indicator ³ 123702 * Enable Cradle LED ³ 123712 ³ 123707 ³ 123717 ³ 123716 ³ 123706 Disable Cradle LED Enable Range Gate - Note: Do not enable this feature unless instructed to by a Honeywell...
Configuration Guide - Page 97

.../Entry Counter ³ 123914 Transmit/Entry Counter - A special audible indicator will not automatically transmit bar code data when placed in the BT cradle. * Transmit Inventory FIFO - 20 MS9535-5M VoyagerBT ³ 123910 ³ 123900 ³ 123903 ³ 123913 ³ 123901 Enable Inventory Mode - The scanner will sound on a first-in the scanner's expanded memory base.
Configuration Guide - Page 98

... Quantity 3) was desired. 1. When the Transmit Quantity Field has been enabled, each scanned quantity code is scanned, it will be stored. Deletes the last bar code stored.. Scan the delete last record bar code. 2. Adds an additional quantity field for the last item (bar code) scanned (see Inventory Quantity Bar Codes, on page 20-3). * Don't Transmit Quantity Field 20-2 ³...
Configuration Guide - Page 103

The scanning cycle is terminated based on the default period of time (2 seconds), a variable period of time, when the I/O signal is deactivated (Low-to-High), or when a bar code is scanned and transmitted. ³ 118110 Activate Scanning on Receipt of a 'D' or when a bar code is used to enable the scanning cycle. A High-to-Low transition on the I /O pin is...
Configuration Guide - Page 104

... 22-2 The laser will blink on/off for a full cycle even when a bar code is the scanning laser-on after the NO READ message has been transmitted. A configurable RTS pulse width ... Scan this bar code with the NO READ message. The laser stays on Laser Time Out ³ 118311 ³ 118301 Activate the LED during the NO READ Transmission ³ 119917 ³ 120303 Enable ...
Connection Guide - Page 1

... differ based on the desktop. II. Once the software is installed, a Bluetooth tray icon is sold at a reduced cost by scanning the Bluetooth address code of the USB adapter you to configure the USB adapter to many users who are using. The color of the icon determines the status of how to connect the Metrologic MS9535-5 scanner to other device. MS9535 VoyagerBT Technical Support...
Connection Guide - Page 2

...communicate with other Bluetooth-Enabled Devices Please follow the below left), highlight Bluetooth Serial Port and click Properties. Right click on the next to the clock and go to Advanced Configuration and click on the Client Applications Tab (see below instructions to configure a MS9535-5 scanner to PC applications expecting keyboard data. 1. MS9535 VoyagerBT Technical Support 1-800-436...
Connection Guide - Page 6

Select the COM port you are connected to start a HyperTerminal session. MS9535 VoyagerBT Technical Support 1-800-436-3876 6 Printed: January 2005 Status: Draft Validate a Serial Connection in HyperTerminal (Windows) Click on the Local Services Tab. The New Connection window will appear, enter a name (Test) and click the OK button (below right) and click OK. 5. You can verify...

Honeywell MK9535-79A540 Reviews

Do you have an experience with the Honeywell MK9535-79A540 that you would like to share?
Earn 750 points for your review!
We have not received any reviews for Honeywell yet.

Popular Honeywell MK9535-79A540 Search Terms

The following terms are frequently used to search for Honeywell MK9535-79A540 support:

Ask a New Question
Use the box below to post a new question about Honeywell MK9535-79A540.
Manuals / Documents
Download any of our Honeywell MK9535-79A540 manuals for free!

We have the following 3 documents available for the Honeywell MK9535-79A540:
  • Configuration Guide
  • User Guide
  • Connection Guide

Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Honeywell Manuals

Find free Honeywell MK9535-79A540 - MS9535 VoyagerBT - Wireless Portable Barcode Scanner manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Honeywell Reviews
Contact Information