All product names are subject to change without notice. ® 1587/1577 Insulation Multimeters Users Manual PN 2401027 April 2005 Rev. 2, 6/09 © 2005-2009 Fluke Corporation. Printed in USA. All rights reserved. Specifications are trademarks of their respective companies.
Product Manual - Page 3

... ...2 Accessories ...4 Unsafe Voltage...4 Test Lead Alert ...4 Battery Saver (Sleep Mode 4 Rotary Switch Positions 5 Buttons ...6 Understanding the Display 8 Input Terminals...11 Power-Up Options ...12 AutoHold Mode...13 MIN MAX AVG Recording Mode 13 Manual Ranging and Autoranging 14 Understanding AC Zero Input Behavior of True RMS Meters 15 Low-Pass Filter (Model 1587 and 1587T 15 i
Product Manual - Page 8

...1587) • Temperature (ModelInsulation testing 1587) 1 1587/1577 Insulation Multimeters Introduction The Fluke Models 1587,1587T, and 1577 are designed to protect against transients from transient impulses. CAT III meters are designed to protect against transients in Fixed equipment installations at the distribution level; CAT IV meters are battery-powered, true-RMS...
Product Manual - Page 9

...with voltages above 30 V ac rms, 42 V ac peak, or 60 V dc. A XWCaution identifies conditions and actions that could damage the Meter, the equipment under test. • Verify the Meter...serviced. • Always use the Meter or test leads if they appear damaged, or if the Meter is not operating properly. 1587/1577 Users Manual O Safety Information Use the Meter only as specified in this manual...
Product Manual - Page 10

....) W Earth Ground Fuse Double Insulated Important information; see manual Do not dispose of electric shock. Go to Fluke's website for continuity before opening ... the test leads, keep your fingers behind the finger guards. • Remove test leads from the Meter before use if the readings are high or noisy. Do not use . Insulation Multimeters Safety Information • Replace the...
Product Manual - Page 11

... if there is displayed. 1587/1577 Users Manual Accessories Model Leads Probes Clips 1587 and 1587T TL224 TP74 AC285 1577 TL224 TL74 AC285 Unsafe Voltage To alert you to the presence of Sleep mode when a key is pressed or when the rotary switched is momentarily displayed when you to check that the test leads are in an incorrect terminal...
Product Manual - Page 12

... "low-pass" filter. Use the blue button to 1000 V. Rotary Switch bav02f.eps Insulation Multimeters Rotary Switch Positions Table 2. DC voltage 1 mV to 600 mV. k (1587 and 1587T only) Temperature from 1 nF to + 998 °F). The temperature measurement you select is retained in Table 2. N (1587 and Capacitance from - 40 °C to + 537 °C (- 40 °F to 9999...
Product Manual - Page 14

.... Causes the Meter to release the display. Insulation Multimeters Buttons Button Description f (1587 and 1587T only) Activate frequency measurement. t Initiates an insulation test when the rotary switch is on the remote probe. Table 3. When a reading changes, the display updates and the Meter beeps. The test lock acts to hold to Manual Ranging mode. The blue button. Buttons...
Product Manual - Page 17

... Model detect error. This message disappears when the rotary switch is turned to perform an insulation test. Service Meter if this is present. 10 Table 5. Appears when insulation test voltage is displayed. The Meter will sound when you move the switch in use 2500V 1000V T Source voltage rating for reliable operation. 1587/1577 Users Manual Table 4. LEAd Test lead...
Product Manual - Page 22

... low pass filter can improve measurement performance on Insulation Multimeters Understanding AC Zero Input Behavior of True RMS Meters composite sine waves that blocks unwanted frequencies above 800 Hz. When the test leads are open, the display readings may be present. First, make a voltage measurement without the filter to Manual mode. Autoranging is equipped with the Low...
Product Manual - Page 32

... the signal source. 2. Press the f button. 5. To measure frequency, set up the Meter as shown in Figure 14 and follow the steps below. 1. Connect the Meter to end this function Figure 13. LO HOLD MIN MAX Insulation Multimeters Making Basic Measurements Measuring Frequency (Model 1587 and 1587T) The Meter measures the frequency of a voltage or current...
Product Manual - Page 35

..., IEC LR6 Figure 16. 1587/1577 Users Manual Replacing the Batteries and Fuse Replace the fuse and batteries as the battery indicator (b) appears. • Use ONLY fuses with the amperage, interrupt, voltage, and speed ratings specified. • Turn the rotary switch to OFF and remove the test leads from the terminals. 1. Replacing the Fuse and Battery Follow...
Product Manual - Page 38

... linearly to crest factor Conversions are ac-coupled and calibrated to the rms value of range. Insulation Multimeters Electrical Specifications 1587 and 1587T Low-Pass Filter Voltage Range Resolution 600.0 mV 0.1 mV 6.000 ...;(2 % + 3) ±(2 % + 3) ±(2 % + 3) ±(2 % + 3) AC Conversion Inputs are true-rms responding and specified from 5 % to 100 % of sine wave input.
Product Manual - Page 40

Insulation Multimeters Electrical Specifications DC and AC Current Measurement Range Accuracy 1587 and 1587T Resolution ±(% of Rdg+Digits) AC 45 Hz to crest ...mA for 2 minutes maximum Overload Protection 440 mA, 1000 V, FAST fuse AC Conversion Inputs are true-rms responding and specified from 5 % to the rms value of range. Input signal crest factor can be up to 3 up to 300 mA, ...
Product Manual - Page 43

... in the ambient temperature of test. Maximum Capacitive Load Operable with up to initialization of the instrument. Insulation Specifications Measurement Range Model 1587 0.01 MΩ to 2 GΩ Model 1577 0.1 MΩ to 600 MΩ Model 1587T 0.01 MΩ to 100 MΩ Test Voltages Model 1587 50, 100, 250, 500, 1000 V Model 1577 500, 1000 V Model 1587T 50, 100 V Test Voltage...

Fluke 1587 T Reviews

Do you have an experience with the Fluke 1587 T that you would like to share?
Earn 750 points for your review!
We have not received any reviews for Fluke yet.

Popular Fluke 1587 T Search Terms

The following terms are frequently used to search for Fluke 1587 T support:

Ask a New Question
Use the box below to post a new question about Fluke 1587 T.
Manuals / Documents
Download any of our Fluke 1587 T manuals for free!

We have the following 1 documents available for the Fluke 1587 T:
  • Product Manual
Related Items
View other Fluke Electronics Accessories:

Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Fluke Manuals

Find free Fluke 1587 T manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Fluke Reviews

View thousands of Fluke 1587 T user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Fluke customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Fluke customer service rankings, employee comments and much more from our sister site.

Fluke Recalls

Find comprehensive Fluke recall information updated hourly on RecallOwl.com.