Find answers below for this question about Yamaha EF2000iS - Inverter Generator.
Need a Yamaha EF2000iS manual? We have 1 online manual for this item!
Question posted by We3m2d on February 28th, 2013

Refrigerator Question

Will the 2000 run a 6.5amp refrig?

Current Answers

Answer #1: Posted by Anonymous-116983 on July 26th, 2013 1:21 PM
Anonymous-116983

Member since:
July 26th, 2013

Points: 0
100
points
amps times volts = watts 6.5 x 120 volts = 780 watts yes with lots left over for power surge when compressor starts up.

Related Yamaha EF2000iS Manual Pages

Owners Manual - Page 1

OWNER'S MANUAL Generator Read this manual carefully before operating this machine. EF2000iS LIT-19626-01-53 7DK-28199-10
Owners Manual - Page 3

If you with a good basic understanding of the operation and maintenance of this machine. AE00022 EF2000iS OWNER'S MANUAL © 2009 by Yamaha Motor Corporation, U.S.A. 1st Edition, January 2009 All rights reserved... of your new Yamaha. is expressly prohibited. This manual will provide you have any questions regarding the operation or maintenance of Yamaha Motor Corporation, U.S.A.
Owners Manual - Page 5

... 26 Muffler screen and spark arrester ......27 Fuel tank filter 29 STORAGE 30 Drain the fuel 30 Engine 32 TROUBLESHOOTING 33 Engine won't start 33 Generator won't produce power .........34 SPECIFICATIONS 36 Dimensions 36 Engine 36 Generator 36 CONSUMER INFORMATION 37 Identification number records 37 Machine identification 37 LIMITED WARRANTY (EF-
Owners Manual - Page 7

... wet hands or electrical shock will occur. 7DK-010 -2- 9 Keep the machine at least 1 m (3 ft) from buildings a or other objects covering it. 9 When covering the generator, be sure to do so only after the engine and muffler have completely cooled down. 9 Be sure to carry the...
Owners Manual - Page 8

... charging the main power line (backfeeding) when the main power sup- 7DK-012 ply has failed or has been turned off for generator power and allows selection of the machine to the ground (Earth) terminal 1 and connect the end to the ground electrode buried in the ground. 7DK-...
Owners Manual - Page 9

door, and vents. -4- Generator exhaust contains carbon monoxide. This is a poison you cannot see or smell. 7DK-014 NEVER.... TIP Maintain or replace safety and instruction labels, as necessary. 1 2 3 4 7DK-013 6 5 1 DANGER Using a generator indoors CAN KILL YOU IN MINUTES. AE00062 LOCATION OF IMPORTANT LABELS Please read the following labels carefully before operating this machine.
Owners Manual - Page 10

... poisonous carbon monoxide. 8 Check for further details. 6 OIL EF2000IS AC output Rated Phase DC output Fuel 60Hz 1.6kVA 120V Single 12V 8A Gasoline YAMAHA MOTOR POWERED PRODUCTS CO.,LTD. 7DK-24164-10 MADE IN JAPAN -5- Refer to the owner's manual. 8 When operating the generator: Never place a partition or other adjustments needed. Do...
Owners Manual - Page 12

...STOP" Ignition circuit is switched off 2 automatically when electric device being connected to the generator is operating and current above the rated flows. AE00111 Oil warning light (Red) When ...position.) 2 "OFF" Direct current is not output. -7- Unless you refill with oil, the engine will not run. The engine will not start , turn on the DC protector by pressing its button to "ON" and then ...
Owners Manual - Page 13

... better 7DK-020 fuel consumption and less noise. 2 3 "OFF" When the economy control switch is turned to "OFF" 2, the engine runs at the rated r/min (4,500 r/min) regardless of the generator if the DC protector turns off again, stop using electric devices that require a large starting current, such as a compressor of a submergible...
Owners Manual - Page 14

... control unit. When the overload indicator light comes on and power generation stops, proceed as a compressor or a submergible pump. After checking, restart the engine. Reduce the total wattage of a connected electrical device is not a malfunction. However, this is detected, the inverter control unit overheats, or the AC output voltage rises. Turn off...
Owners Manual - Page 15

...always the generator must be earthed. 7DK-011 7DK-042a Twin Tech (Terminal for Connecting special cables for parallel running) This is the terminal for connecting special cables for parallel running of electric...knob to "OFF" to stop fuel flow. The parallel running requires two EF2000iS and the special cables. (The rated output in parallel running is 3.0 kVA and the rated current is 25.0 A.)...
Owners Manual - Page 17

Do not start the engine till fill with the sufficient engine oil. 1. Place the generator on a level surface. 2. Install the cover and tighten the screws. - 12 - Remove the screws 1, and then remove the cover 2. 1 2 7DK-030 1 ...: API Service SE type or higher Engine oil quantity: 0.4 L (0.42 US qt, 0.35 lmp qt) 5. AE00222 Engine oil NOTICE The generator has been shipped without engine oil.
Owners Manual - Page 18

... used. TIP Pre-operation checks should be made each time the generator is the owner's responsibility. The point where abnormality was recognized by use...Pre-operation check is not working properly, have it inspected and repaired before operating the generator. Vital components can start to specified level. 9 Check generator for crack or damage. 9 Replace if necessary. Engine oil (See page 12) ...
Owners Manual - Page 19

... the engine, do not connect any electric devices. Starting the engine 1. Turn the fuel cock knob to "ON" 1. 1 Air vent knob 7DK-035 3. NOTICE The generator has been shipped without engine oil.
Owners Manual - Page 20

...stop when the choke knob is engaged, then pull it is returned to prevent the generator from falling over when pulling the recoil starter. 7DK-041 7. The economy control unit ... is not required to start a warm engine. Pull slowly on the generator: 7DK-042 9 in ambient temperature below 0°C (32°F), the engine will run at the 4,500 r/min for 5 minutes to warm up the engine...
Owners Manual - Page 22

..." 1. 1 I "ON" 5. Make sure the AC pilot light 1 is earthed, always the generator must be earthed. 1. Plug in . TIP 1 The economy control switch must be turned to "OFF" to... the lines and plug connections are turned off before connection to the generator. 9 Be sure the total load is within generator rated output. 9 Be sure the receptacle load current is within receptacle...
Owners Manual - Page 23

... charging. 9 Before starting to start battery charging. To restart charging the battery, turn the DC protector on . 2 1 1 Red wire 2 Black wire 1. Battery Charging TIP 9 The generator DC rated voltage is turned off 2 automatically if current above the rated flows during battery 21 7DK-052 charging. Start the engine. 2. connected due to...
Owners Manual - Page 25

... the application range. (See page 9 for further advice. - 20 - The total load of all electrical appliances must not exceed the supply range of a generator. DC AC Power factor EF2000iS 1 -1,600W 0.8-0.95 -1,280W 0.4-0.75 (Efficiency 0.85) -544W Rated voltage 12V Rated current 8A 1 7DK-021 TIP 9 "-" means below. 9 Application wattage indicates when each...
Owners Manual - Page 41

... (in) mm (in) kg (lb) EF2000iS 490 (13.3) 280 (11.0) 455 (17.9) 20 (44) AE00704 Engine Unit EF2000iS Type Cylinder Arrangement Displacement cm3 Bore ×...NGK) 0.6-0.7 (0.024-0.028) 61 * : Measured at rated operation from 7 m (23 ft) distance. AE00707 Generator Unit AC Output Rated voltage V Rated frequency Hz Rated current A Rated output kVA Safety Device: Type DC Output ...
Owners Manual - Page 44

... Manual. WARRANTY DEPARTMENT P.O. has an up -to-date list of all costs of your name and new mailing address. WARRANTY QUESTIONS AND ANSWERS Q. A. Q. Specific examples include: Running the machine out of the generator before sale. 2. If you must take it is in areas. No. CUSTOMER SERVICE If your request at the dealer level...

Similar Questions

Hi There My Yamaha Ef2400is Generator Wont Run Without The Choke On, Thanks
Hi there my Yamaha EF2400iS Generator wont run without the choke on, and it trips when under load. T...
(Posted by wade1bel 9 years ago)
Generator Yamaha Ef2ooois Won't Start Fuel Is Clean
can't get generator to start clean fuel cant find fuel filter from manual
(Posted by mgletch 9 years ago)
Connecting Two Generators Together
what is the placement of the red and black wires and do they have to be exactly the same on both uni...
(Posted by zookatie01 11 years ago)
Ask a New Question
Use the box below to post a new question about this Yamaha product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Yamaha Manuals

Find free Yamaha EF2000iS - Inverter Generator manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Yamaha Reviews

View thousands of Yamaha user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Yamaha customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Yamaha customer service rankings, employee comments and much more from our sister site.

Yamaha Recalls

Find comprehensive Yamaha recall information updated hourly on RecallOwl.com.