Get support for Rheem 14AJM

Rheem 14AJM Support Question

Rheem 14AJM Support Question

Find answers below for this question about Rheem 14AJM.
Need a Rheem 14AJM manual? We have 3 online manuals for this item!
Question posted by hyunchulko8 on September 19th, 2023

Air Conditioner Capacitor Part Number Of 14ajm49a01

I need capacitor part number of 14AJM49A01, searial no. of 8254W441203299.

Current Answers

Answer #1: Posted by Niluzala on September 19th, 2023 9:58 AM
This answer was accepted by the poster of the original question.
Niluzala

Member since:
September 15th, 2023

Points: 7,010
1,100
points
The air conditioner capacitor part number for 14AJM49A01 is **RPDMDL-14AJM**. This is a 30uF 370-440VAC oval run capacitor.

If you are replacing the capacitor in your 14AJM49A01 air conditioner, it is important to use the correct capacitor. Using the wrong capacitor can damage your air conditioner and void your warranty.

You can purchase a replacement capacitor from your local HVAC parts supplier or online.

Here are some tips for replacing the capacitor in your air conditioner:


1. Disconnect the power to your air conditioner.

2. Locate the capacitor. It is typically located near the compressor.

3. Discharge the capacitor using a capacitor tester or a screwdriver with an insulated handle.

4. Disconnect the wires from the capacitor.

5. Install the new capacitor.

6. Connect the wires to the new capacitor.

7. Reconnect the power to your air conditioner.


If you are not comfortable replacing the capacitor yourself, you can hire a professional HVAC technician to do it for you.


N.V.Z
Answer #2: Posted by SonuKumar on September 19th, 2023 10:58 AM
SonuKumar

Member since:
May 9th, 2021

Points: 16,604,600
100
points
The Rheem 14AJM Air Conditioner Capacitor Part Number Of 14ajm49a01 is RPDMDL-14AJM.

This is a dual capacitor that contains both a start and run capacitor. The start capacitor provides a boost of power to help the compressor motor start up, while the run capacitor provides continuous power to the compressor motor while it is running.

If you are experiencing problems with your Rheem 14AJM air conditioner, such as the compressor not starting up or the unit running intermittently, it is possible that the capacitor is faulty. If you suspect that the capacitor is bad, it is important to have it replaced by a qualified HVAC technician.


Please respond to my effort to provide you with the best possible solution by using the "Acceptable Solution" and/or the "Helpful" buttons when the answer has proven to be helpful.

Regards,
Sonu
Your search handyman for all e-support needs!!

Related Rheem 14AJM Manual Pages

Brochure - Page 1

... by a 10-year conditional parts warranty. INTEGRATED HOME COMFORT Rheem.com Air Air Conditioners 14AJM Series reliability at an AFF RDABLE PRICE With the Rheem Value Series Air Conditioner, you get a higher level of comfort that every lifestyle deserves, and every budget can handle. 14AJM Series Efficiencies up to 16.5 SEER Energy Savings Innovative comfort solution based...
Brochure - Page 2

...protection extends the coverage length and type of Reliable Comfort The Rheem Value Series Air Conditioner is critical to provide comfort you , or visit Rheem.com/ProtectionPlus. Our ...improvement, Rheem reserves the right to a minimum. Ask your cost to make most reliable air conditioners available. Box 17010 Fort Smith, Arkansas 72917 Rheem Canada Ltd./Ltée 125 Edgeware...
Use and Care Manual - Page 1

...level or rooftop installations. Note: Above image does not show deep drawn basepan. • Outdoor air conditioner designed for quiet fan operation • Filter Drier (shipped - A11-215 not installed) FORM ...critical to achieve optimal performance. Air Conditioners Air 14AJM Series Rheem Value Series Air Conditioners 14AJM- Ask your Contractor for details or visit www.energystar.gov."
Use and Care Manual - Page 2

Table of Contents Air 14AJM Series TABLE OF CONTENTS Model Number Identification 3 Accessories...3 Scroll Compressor 3 Performance Data 4-35 Electrical & Physical Data 36 Unit Dimensions 37 Refrigerant Line Size Information 38 Limited Warranty 39 2
Use and Care Manual - Page 3

... advanced scroll compressor offers low noise and vibration characteristics and features tolerance to liquid refrigerant and system contamination. Model I.D./Accessories/Compressor Air 14AJM Series Model Number Identification 14 A J 14.5 SEER A = AIR CONDITIONER VOLTAGE J = 208-230 SINGLE PHASE M DESIGN SERIES M = 1ST DESIGN R-410A 18 NOMINAL COOLING CAPACITY 18 = 18,000 BTU/HR [5.28 kW...
Use and Care Manual - Page 4

... Performance Data @ AHRI Standard Conditions-Cooling Model Numbers 80°F [26.5°C] DB/67°F [19.5°C] WB Indoor Air 95°F [35°C] DB Outdoor Air Outdoor Unit 14AJM Indoor Coil and/or Air Handler Total Net Net Capacity Sensible Latent EER BTU/H [kW] BTU/H [kW] BTU/H [kW] Rev. 6/14/12 RCFL-H*2417 ➀...
Use and Care Manual - Page 5

....50 74 800 [378] [ ] Designates Metric Conversions 5 Performance Data Air 14AJM Series Performance Data @ AHRI Standard Conditions-Cooling Model Numbers 80°F [26.5°C] DB/67°F [19.5°C] WB Indoor Air 95°F [35°C] DB Outdoor Air Outdoor Unit 14AJM Indoor Coil and/or Air Handler Total Net Net Capacity Sensible Latent EER BTU/H [kW...
Use and Care Manual - Page 6

... Performance Data @ AHRI Standard Conditions-Cooling Model Numbers 80°F [26.5°C] DB/67°F [19.5°C] WB Indoor Air 95°F [35°C] DB Outdoor Air Outdoor Unit 14AJM Indoor Coil and/or Air Handler Total Net Net Capacity Sensible Latent EER BTU/H [kW] BTU/H [kW] BTU/H [kW] Rev. 6/14/12 RCFL-H*2417(RGPE...
Use and Care Manual - Page 7

....10 76 875 [413] [ ] Designates Metric Conversions 7 Performance Data Air 14AJM Series Performance Data @ AHRI Standard Conditions-Cooling Model Numbers 80°F [26.5°C] DB/67°F [19.5°C] WB Indoor Air 95°F [35°C] DB Outdoor Air Outdoor Unit 14AJM Indoor Coil and/or Air Handler Total Net Net Capacity Sensible Latent EER BTU/H [kW...
Use and Care Manual - Page 8

... Performance Data @ AHRI Standard Conditions-Cooling Model Numbers 80°F [26.5°C] DB/67°F [19.5°C] WB Indoor Air 95°F [35°C] DB Outdoor Air Outdoor Unit 14AJM Indoor Coil and/or Air Handler Total Net Net Capacity Sensible Latent EER BTU/H [kW] BTU/H [kW] BTU/H [kW] Rev. 6/14/12 RCFL-A*3621(RGFE...
Use and Care Manual - Page 9

... Performance Data @ AHRI Standard Conditions-Cooling Model Numbers 80°F [26.5°C] DB/67°F [19.5°C] WB Indoor Air 95°F [35°C] DB Outdoor Air Outdoor Unit 14AJM Indoor Coil and/or Air Handler Total Net Net Capacity Sensible Latent EER BTU/H [kW] BTU/H [kW] BTU/H [kW] Rev. 6/14/12 RCFL-A*3821(RGPT...
Use and Care Manual - Page 10

... 76 950 [448] [ ] Designates Metric Conversions 10 Performance Data Air 14AJM Series Performance Data @ AHRI Standard Conditions-Cooling Model Numbers 80°F [26.5°C] DB/67°F [19.5°C] WB Indoor Air 95°F [35°C] DB Outdoor Air Outdoor Unit 14AJM Indoor Coil and/or Air Handler Total Net Net Capacity Sensible Latent EER BTU/H [kW...
Use and Care Manual - Page 11

... 76 1,025 [484] [ ] Designates Metric Conversions 11 Performance Data Air 14AJM Series Performance Data @ AHRI Standard Conditions-Cooling Model Numbers 80°F [26.5°C] DB/67°F [19.5°C] WB Indoor Air 95°F [35°C] DB Outdoor Air Outdoor Unit 14AJM Indoor Coil and/or Air Handler Total Net Net Capacity Sensible Latent EER BTU/H [kW...
Use and Care Manual - Page 12

... [425] [ ] Designates Metric Conversions 12 test procedures. Performance Data Air 14AJM Series Performance Data @ AHRI Standard Conditions-Cooling Model Numbers 80°F [26.5°C] DB/67°F [19.5°C] WB Indoor Air 95°F [35°C] DB Outdoor Air Outdoor Unit 14AJM Indoor Coil and/or Air Handler Total Net Net Capacity Sensible Latent EER BTU/H [kW...
Use and Care Manual - Page 13

... Performance Data @ AHRI Standard Conditions-Cooling Model Numbers 80°F [26.5°C] DB/67°F [19.5°C] WB Indoor Air 95°F [35°C] DB Outdoor Air Outdoor Unit 14AJM Indoor Coil and/or Air Handler Total Net Net Capacity Sensible Latent EER BTU/H [kW] BTU/H [kW] BTU/H [kW] Rev. 6/14/12 RCQD-3621(RGPT...
Use and Care Manual - Page 14

... [507] [ ] Designates Metric Conversions 14 test procedures. Performance Data Air 14AJM Series Performance Data @ AHRI Standard Conditions-Cooling Model Numbers 80°F [26.5°C] DB/67°F [19.5°C] WB Indoor Air 95°F [35°C] DB Outdoor Air Outdoor Unit 14AJM Indoor Coil and/or Air Handler Total Net Net Capacity Sensible Latent EER BTU/H [kW...
Use and Care Manual - Page 15

... Performance Data @ AHRI Standard Conditions-Cooling Model Numbers 80°F [26.5°C] DB/67°F [19.5°C] WB Indoor Air 95°F [35°C] DB Outdoor Air Outdoor Unit 14AJM Indoor Coil and/or Air Handler Total Net Net Capacity Sensible Latent EER BTU/H [kW] BTU/H [kW] BTU/H [kW] Rev. 6/14/12 RCFL-A*3621(RGRM...
Use and Care Manual - Page 16

... 77 1,175 [554] [ ] Designates Metric Conversions 16 Performance Data Air 14AJM Series Performance Data @ AHRI Standard Conditions-Cooling Model Numbers 80°F [26.5°C] DB/67°F [19.5°C] WB Indoor Air 95°F [35°C] DB Outdoor Air Outdoor Unit 14AJM Indoor Coil and/or Air Handler Total Net Net Capacity Sensible Latent EER BTU/H [kW...
Use and Care Manual - Page 17

... [578] [ ] Designates Metric Conversions 17 test procedures. Performance Data Air 14AJM Series Performance Data @ AHRI Standard Conditions-Cooling Model Numbers 80°F [26.5°C] DB/67°F [19.5°C] WB Indoor Air 95°F [35°C] DB Outdoor Air Outdoor Unit 14AJM Indoor Coil and/or Air Handler Total Net Net Capacity Sensible Latent EER BTU/H [kW...
Use and Care Manual - Page 18

... 77 1,200 [566] [ ] Designates Metric Conversions 18 Performance Data Air 14AJM Series Performance Data @ AHRI Standard Conditions-Cooling Model Numbers 80°F [26.5°C] DB/67°F [19.5°C] WB Indoor Air 95°F [35°C] DB Outdoor Air Outdoor Unit 14AJM Indoor Coil and/or Air Handler Total Net Net Capacity Sensible Latent EER BTU/H [kW...

Similar Questions

I Have A Rheem 14ajm (14ajm49a01) , Serial No. 8254w411003386.
I have a Rheem 14AJM (14AJM49A01) , serial no. 8254W411003386. Please confirm that this unit/model i...
(Posted by rkthoe 7 years ago)
14ajm - Compressor Time Delay Control
I have a Rheem 14AJM (14AJM49A01) , serial no. 8254W411003386. Please confirm that this unit/model i...
(Posted by rkthoe 7 years ago)
Regarding Filter For Rheem 14ajm Series-serial #: N161500219
Should I use the filter that came with the unit or buy a pleated filter or could I use a reusable fi...
(Posted by bennie2 8 years ago)
Seer Rating
I am told a condenser unit of 14.5 SEER and a high efficiency air handler add up to 16 SEER. Is that...
(Posted by muvingi 10 years ago)
Air Handler Rhlp-hm36ja
For 13ajn36 3 Ton 13 Seer What Air Handler Should Be Used.'what About Can't Find It
(Posted by pattybrown 10 years ago)
Ask a New Question
Use the box below to post a new question about this Rheem product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Rheem Manuals

Find free Rheem 14AJM manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Rheem Reviews

View thousands of Rheem user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Rheem customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Rheem customer service rankings, employee comments and much more from our sister site.

Rheem Recalls

Find comprehensive Rheem recall information updated hourly on RecallOwl.com.