Get support for Maytag MEDE300VF - Performance Series Front Load Electric Dryer

Maytag MEDE300VF Support Question

Maytag MEDE300VF Support Question

Find answers below for this question about Maytag MEDE300VF - Performance Series Front Load Electric Dryer.
Need a Maytag MEDE300VF manual? We have 1 online manual for this item!
Question posted by 7shbzi on June 15th, 2014

Maytag 3000 Series Electric Dryer How To Replace Belt

The person who posted this question about this Maytag product did not include a detailed explanation. Please use the "Request More Information" button to the right if more details would help you to answer this question.

Current Answers

There are currently no answers that have been posted for this question.
Be the first to post an answer!

Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.

Related Maytag MEDE300VF Manual Pages

Use and Care Guide - Page 1

ELECTRIC DRYER USE & CARE GUIDE SÉCHEUSE ÉLECTRIQUE GUIDE D'UTILISATION ET D'ENTRETIEN FOR QUESTIONS ABOUT FEATURES, OPERATION/PERFORMANCE, PARTS, ACCESSORIES OR SERVICE CALL: 1.800.688.9900 IN CANADA, CALL: 1.800.807.6777 VISIT OUR WEBSITE AT WWW.MAYTAG.COM IN CANADA, WWW.MAYTAG.CA W10057349A SI TIENE PREGUNTAS RESPECTO A LAS CARACTERÍSTICAS, FUNCIONAMIENTO, RENDIMIENTO...
Use and Care Guide - Page 3

...dryer is used near children. ■ Before the dryer is removed from the accumulation of lint, dust, and dirt. ■ The interior of fire, electric...replace any part of the dryer or attempt any servicing unless specifically recommended in the dryer. Always read and obey all instructions before using the dryer...Clean lint screen before or after each load. ■ Keep area around the ...
Use and Care Guide - Page 4

.... Door Reversal Kit Are you are installing your washer and dryer? Backguard If you planing to the "Assistance or Service" section. See "Electrical Requirements" and "Venting Requirements" before starting installation. You have the option of purchasing pedestals of items falling behind your PERFORMANCE SERIES dryer? To order, call the dealer from whom you purchased your...
Use and Care Guide - Page 5

... floor moldings. „ Additional spacing should also be considered on the sides and rear. Place dryer at temperatures below 45ºF (7ºC). At lower temperatures, the dryer might be required for a garage installation. Check code requirements. See "Electrical Requirements." „ A sturdy floor to water and/or weather. Clothes may not tumble properly and...
Use and Care Guide - Page 7

... secured under the neutral terminal (center or white wire) of the terminal block. Connect to the neutral conductor (white wire) within the dryer. Electrical Requirements - If the dryer is prohibited. A copy of the above code standards can be obtained from the neutral conductor. „ If local codes do not permit the connection of...
Use and Care Guide - Page 8

... an appropriate outlet that connect to the equipment-grounding terminal or lead on the power supply cord: if it will reduce the risk of electric shock. This dryer uses a cord having an equipment-grounding conductor and a grounding plug. Check with a qualified electrician or service representative or personnel if you are in doubt...
Use and Care Guide - Page 9

... 4-wire receptacle 14-30R „ Do not use Power Supply Cord Replacement Part Number 9831317. GROUNDING INSTRUCTIONS ■ For a grounded, cord-connected dryer: This dryer must be grounded. Be sure wall receptacle is equipped with all local codes. Check with the Canadian Electrical Code, C22.1-latest edition and all local codes and ordinances. For...
Use and Care Guide - Page 11

... relief should have a tight fit with the dryer cabinet and be in a horizontal position. Style 2: Direct wire strain relief „ Unscrew the removable conduit connector and any screws from a 3/4" (1.9 cm) UL listed strain relief (UL marking on the power supply cord is not available) Electrical Connection Options If your type of the...
Use and Care Guide - Page 12

... center wire) E. ¾" (1.9 cm) UL listed strain relief 5. Direct wire cable must have completed your electrical connection. Ground prong D. Connect neutral ground wire and the neutral wire (white or center wire) of extra length so dryer can be moved if needed. 12 External ground conductor screw B. Dotted line shows position of power...
Use and Care Guide - Page 13

...squeeze hooked end together and tighten screw, as shown. Dotted line shows position of dryer rear panel. External ground conductor screw B. Center silver-colored terminal block screw E. ... terminal block cover into a hook shape. 1" (2.5 cm) 3. You have completed your electrical connection. Strip insulation back 1" (2.5 cm). Connect ground wire (green or bare) of the...
Use and Care Guide - Page 14

...;" (1.9 cm) UL listed strain relief 1. Direct wire cable must have completed your electrical connection. Neutral ground wire C. Shape ends of wires into slot of the terminal block... connecting to the terminal block, place the hooked end of the wire under the screw of dryer rear panel. Spade terminals with outer covering. Strip insulation back 1" (2.5 cm). Connect neutral wire...
Use and Care Guide - Page 15

..., silver-colored terminal block screw. Tighten strain relief screws. 5. Insert tab of terminal block cover into slot of dryer rear panel. down screw. 15 B A C D E A. Center silver-colored terminal block screw D. You have completed your electrical connection. Neutral ground wire D. Remove center silver-colored terminal block screw. 2. Tighten strain relief screw. 5. Insert tab...
Use and Care Guide - Page 16

... vent system „ Clean lint from your dealer or by calling Maytag Services. The dryer exhaust must not be connected into the interior of a building. If this dryer MUST BE EXHAUSTED OUTDOORS. Do not use a plastic vent. Failure to achieve the best drying performance. 4" 10.2 cm 4" (10.2 cm) heavy metal exhaust vent Vent products...
Use and Care Guide - Page 20

... levelness. See "Troubleshooting". „ If you receive an AF code, your dryer vent may notice a burning odor when the dryer is made, remove the corner posts and cardboard. The odor will not start of...: You may be a problem with your tools. 3. Dispose of the dryer. Move dryer into a grounded outlet and/or electrical supply is an extra part, go away. 20 Check levelness first side ...
Use and Care Guide - Page 21

...132; Press the POWER/CANCEL button. „ Rotate the dial to starting your dryer. Failure to select either a Sensor or Timed Cycle. Failure to each load. The preset settings and drying time for more detailed information. 1. time based on..., the cycle time may not have all of fire, electric shock, or injury to specific sections of this appliance. Place laundry in death or fire.
Use and Care Guide - Page 27

... the Lint Screen Every load cleaning The lint screen is located in death, explosion, or fire. 4. A screen blocked by lint can cause longer drying times for your load is hard to a ... temperature setting and drying time. Replace screen in the dryer. Time* (Minutes) Wool Sweaters Timed Low 60 Block to complete drying, if needed cleaning Laundry detergent and fabric softener residue can ...
Use and Care Guide - Page 28

..., or more often, depending on dryer usage. Open the dryer door. Cleaning the Dryer Interior To clean dryer drum 1. To change the drum light 1. For direct-wired dryers: WARNING Electrical Shock Hazard Disconnect power before operating. Use masking tape to do so can result in dryer base. 4. Make a paste with powdered laundry detergent and very warm water. 2. Moving...
Use and Care Guide - Page 29

.... „ Is the correct power supply available? Electric dryers use 2 household fuses or circuit breakers. Electric dryers use two household fuses or breakers. Dryer displaying code message „ "PF" (power failure), check the following : Clean lint screen. Replace the fuse or reset the circuit breaker. Refer to "Electrical Connection" for details. TROUBLESHOOTING First try the...
Use and Care Guide - Page 31

... so, ventilate the area. The new electric heating element may save you use only factory specified parts. It may have an odor. Maytag® appliances designated service technicians are wrinkled „ Was the load removed from the area, rewash and dry the clothing. „ Is the dryer being used for assistance or service, please...
Use and Care Guide - Page 32

...according to instructions attached to or furnished with electrical or plumbing codes, or use of consumables or cleaning products not approved by Maytag. 5. Repairs to better help by checking the...made to correct defects in a remote area where service by calling Maytag. Any food loss due to repair or replace appliance light bulbs, air filters or water filters. IMPLIED WARRANTIES, ...

Maytag Knowledge Base Results

We have determined that the information below may contain an answer to this question. If you find an answer, please remember to return to this page and add it here using the "I KNOW THE ANSWER!" button above. It's that easy to earn points!

  • Dryer does not heat - Electric dryer
    Electric dryer My electric dryer does not heat. Did you may not have heat. Gas dryer FAQs Knowledgebase search tips My dryer will not start Damp loads or long drying times - Dryer Expect loads dried with the ... be found on the dryer? If the problem continues, call an electrician. Loads are damp; dryer does not dry Dryer does not heat - Dryer does not heat - Replace the fuses or reset ...
  • Dispensers not working correctly - Front-load Epic washer
    ...) to ensure the best cleaning performance. For liquid detergent, the separator should be in the front position for liquid detergent and in the appropriately marked compartments. The fabric softener automatically dispenses during the first rinse to dispense early; Front-load Neptune® Make sure the laundry products (detergent, fabric softener, liquid...
  • Display shows L2 - Dryer
    ...Replace the fuse(s) or reset the circuit breaker(s). Does the dryer have heat. If the dryer drum is not turning and there is the load not tumbling? Select a Timed Dry heated cycle, and restart the dryer... dryer. Is the dryer drum not turning, or is  an L2 code on , even if the dryer drum is turning and the load is tumbling. Dryer does not heat - Electric dryers ...

Similar Questions

Error Code F 01 On Maytag 3000 Series Dryer.
Dryer Worked Fine An Hour Ago, And Now When I Try To Dry Last Load Of Laundry, It Makes A 'clicking'...
(Posted by gwyndehn 9 years ago)
Maytag 3000 Series Electric Dryer Getting Extremely Hot!
My MEDE300VW0 Dryer is getting way too hot on every cycle. We cleaned out the vents. Even on air dry...
(Posted by angietorix 9 years ago)
Ask a New Question
Use the box below to post a new question about this Maytag product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Maytag Manuals

Find free Maytag MEDE300VF - Performance Series Front Load Electric Dryer manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Maytag Reviews

View thousands of Maytag user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Maytag customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Maytag customer service rankings, employee comments and much more from our sister site.

Maytag Recalls

Find comprehensive Maytag recall information updated hourly on RecallOwl.com.