Hunter 44860 Support Question
Find answers below for this question about Hunter 44860.Need a Hunter 44860 manual? We have 2 online manuals for this item!
Question posted by russryder40 on October 20th, 2013
Screen Will Not Illuminate Red In Heat Mode
The person who posted this question about this Hunter product did not include a detailed explanation. Please use the "Request More Information" button to the right if more details would help you to answer this question.
Current Answers
There are currently no answers that have been posted for this question.
Be the first to post an answer! Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.
Be the first to post an answer! Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.
Related Hunter 44860 Manual Pages
Owner's Manual - Page 2
Touchscreen Programmable Thermostat Model 44860
2 Stage Heat/2 Stage Cool
installation and operation manual
Owner's Manual - Page 4
Please read this manual before beginning installation and save this booklet for choosing a Hunter programmable thermostat. Thank you for complete operating instructions.
Your new Hunter thermostat will provide years of reliable service and year-round energy savings. 44002-01 r051807
Touchscreen Programmable Thermostat Model 44860 2 Stage Heat/2 Stage Cool
Congratulations!
Owner's Manual - Page 5
... have, please contact a qualified HVAC Technician for mounting. IMPORTANT INFORMATION
This thermostat is designed to work on the following heating and cooling systems:
Up to 2 Stage Heat/2 Stage Cool Heat Only or Cool Only Systems Single and Multi-Stage Heat Pumps Gas, Electric or Oil Systems
Millivolt Systems 2-wire Hydronic Systems AC or Hard-wired...
Owner's Manual - Page 11
...:
CONVENTIONAL HVAC SYSTEMS
label the wire with this sticker:
if your existing thermostat is marked:
label the wire with this sticker:
Y1 / Y2
Cooling Stage 1 or 2
Y1 Y2
Y2 Y1
R/RC
R / RC
Cooling Transformer Power Supply
R/RC
W1 / W2
Heating Stage 1 or 2
W1 W2
W2 W1
C
C
24 VAC Common
(if available)
C
G
G Fan...
Owner's Manual - Page 12
... wire with this sticker:
if your existing thermostat is marked:
label the wire with this sticker:
Y1 / Y2
Compressor Stage 1 or 2
Y1 Y2
Y2 Y1
C 24 VAC Common
C
C
O
W2 Auxilliary Heat
W2
W2
O
Cool Mode Powered
Reverse Valve
O
G Fan
G
G
E Emergency Heat
E
E
R/RC
R / RC
24 VAC Power Supply
R/RC
B
B
Heat Mode Powered
Reverse Valve
B
L
L System Monitor
L
See...
Owner's Manual - Page 22
... r051807
21 The front of the thermostat is easy to the pressure of a finger. You can program the thermostat to automatically readjust the temperature and airflow to settings that responds to program and use the pre-programmed default settings.
GENERAL OPERATING INSTRUCTIONS
Your new Hunter thermostat is a touch screen that you choose or you...
Owner's Manual - Page 27
With the STAGE TIMER (Option 10) set to run longer;
SETTING the span
The SPAN setting mode in the SYSTEM SETTINGS MENU allows you to run for Heating and Cooling.
26
44002-01 r051807 The span setting can be controlled by the SPAN setting only. a lower number will decrease your cycle time by...
Owner's Manual - Page 28
SYSTEM: CONVENTIONAL (CONVENTIONAL, HEAT PUMP) 2. STAGE TWO SPAN (not available on page 26): 2F (1F, 2F, 3F) 4. AUTO ...3. See pages 28-29 to change these settings.
1. SYSTEM SETTINGS MENU
The installer can set SYSTEM functions once the thermostat is CONVENTIONAL with (HEAT PUMP) as a second option. RESIDUAL COOLING TIMER: 30 seconds (0, 30, 60, 90) 9. Options are shown in...
Owner's Manual - Page 31
....
30
44002-01 r051807
The REFRESH FAN ON (Option 3) function runs only the fan during heating or cooling off cycles. USER SETTINGS
The PERIODS PER DAY (Option 1) can be set to 0, the thermostat operates as a digital non-programmable thermostat. When set from 30-360 days in 15-day increments (the default is 90).
Owner's Manual - Page 35
By using the preprogrammed and default settings, this thermostat can save you money by optimizing energy usage in heating and cooling.
30o F (0o C)
45o F
(7o C)
95o F (35o C)
99o F
(37o C)
Out of Range
"LO"
99o F
34
44002-01 r051807 TEMPERATURE RANGE
This thermostat meets ENERGY STAR guidelines for energy efficiency.
Owner's Manual - Page 36
... Star Default Programs Chart shown below by pressing the icon in the program mode.
10 pm
Program 4
Heat : 60o F (16o C) Cool : 82o F (28oC)
Program 3
Heat : 68o F (20o C) Cool : 78o F (26o C)
4 pm
6 am Program 1
Heat : 68o F (20o C) Cool : 78o F (26o C)
8 am
Program 2
Heat : 60o F (16o C) Cool : 85o F (29o C)
44002-01 r051807
35 ENERGY STAR DEFAULT PROGRAMS...
Owner's Manual - Page 37
See USER SETTINGS MENU (pages 31-33). SET HEAT OR AC SYSTEM MODE
MAY 17 2006 THURSDAY
1
2
3
5
6
47
36
44002-01 r051807
MANUAL OPERATION
Many people prefer to 0 for manual operation. NOTE: PROGRAMS PER DAY must be set to operate their thermostats manually, adjusting settings as needed.
Owner's Manual - Page 38
... r051807
37
Touch
to return to select one of the touch screen.
Touch the or sign to make the temperature change more quickly.
7. Touch a blank area of the SYSTEM modes: HEAT ( icon, red screen) EMHEAT (only for Heat Pump Systems)
AUTO ( and icons) COOL ( icon, blue screen) OFF (no icon)
4. NOTE: Setting the override temperature to high...
Owner's Manual - Page 40
Program temperatures are set in 10-minute increments. Press
to
exit Program Mode at any period icon to 2 or 4 in increments of inactivity during programming, the thermostat returns to four times per day. NOTE: Program times are indicated by the following icons:
Sunrise
Daytime
Evening
Nighttime
44002-01 r051807
39 The PROGRAMS ...
Owner's Manual - Page 42
... the top of the display. (Image P2)
4. Touch the day(s) to select mode.
7. Touch the or icon to be programmed.
Touch the icon. SELECT ICON TO PROGRAM appears at the top of the display along with the days of the screen to each day selected.
5. Touch one of the display. (Image P1...
Owner's Manual - Page 46
... the fan is running and the icon is on for one of the fan modes:
ON: Fan runs continuously regardless of the touch screen. AUTO: Fan runs when the system is touched, it will bring up the SET FAN screen.
44002-01 r051807
45
Touch
to return to select one hour. NOTE: If...
Owner's Manual - Page 64
... operate if Permanent or Temporary Holds are on.
44002-01 r051807
63 When the thermostat is in AUTO RECOVERY mode, the display flashes alternatively SYSTEM IN AUTO RECOVERY and the weekday. AUTO RECOVERY
The AUTO RECOVERY FUNCTION allows heating and cooling systems to gradually recover from an energy-saving set point temperature to...
Owner's Manual - Page 67
... automatically turns the system off .
The screen flashes a SYSTEM ERROR message and shuts the system off if the temperature rises above 95°F (35°C) or drops below 40°F (4°C).
You must reset and the thermostat by replacing the batteries if the thermostat has entered ERROR mode. NOTE: If the HVAC system has...
Owner's Manual - Page 70
The display comes on or off.
5a. My system continues to operate when the thermostat is closed properly. 5f. There may be as much as a 4-minute delay before... override mode. 5b. If your system has 4 wires, ensure the jumper is not in the off to the
system. 5d. The heating or cooling will not turn on but does not stay illuminated.
6a. 5. Make sure the thermostat is ...
Owner's Manual - Page 71
If ERR message remains after battery replacement, then replace unit.
9. How do I just operate my thermostat manually?
9a. Manual operation instructions begin on page 38.
70
44002-01 r051807 Refer to page 66 for ERROR mode instructions. The touch screen permanently reads SYSTEM ERROR.
8a. 8.
Similar Questions
Hunter Thermostat 44860 What Do You Set It At To Heat Your House Manually?
(Posted by krusAxiom 9 years ago)
Hunter Thermostat 44860 How To Turn Of Fan And Air Conditioning On
(Posted by oldsarielb 10 years ago)