Question posted by delenrjpot on January 24th, 2014

How To Hook Up A Hunter 44860 5 Wire

The person who posted this question about this Hunter product did not include a detailed explanation. Please use the "Request More Information" button to the right if more details would help you to answer this question.

Current Answers

There are currently no answers that have been posted for this question.
Be the first to post an answer!

Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.

Related Hunter 44860 Manual Pages

Owner's Manual - Page 1

Hunter Fan 2500 Frisco Ave. Memphis, TN 38114 888-830-1326 www.hunterfan.com
Owner's Manual - Page 2

Touchscreen Programmable Thermostat Model 44860 2 Stage Heat/2 Stage Cool installation and operation manual
Owner's Manual - Page 3

... 35 MANUAL OPERATION 36 PROGRAM OPERATION 39 PROGRAM OVERRIDES 46 ADDITIONAL FEATURES 56 CLEAN SCREEN 56 CHANGE FILTER 60 ENERGY MONITOR FUNCTION 64 TROUBLESHOOTING 68 WIRING DIAGRAMS 72  44002-01 r051807
Owner's Manual - Page 4

44002-01 r051807 Touchscreen Programmable Thermostat Model 44860 2 Stage Heat/2 Stage Cool Congratulations! Your new Hunter thermostat will provide years of reliable service and year-round energy savings. Please read this manual before beginning installation and save this booklet for choosing a Hunter programmable thermostat. Thank you for complete operating instructions. 
Owner's Manual - Page 5

... Heat/2 Stage Cool Heat Only or Cool Only Systems Single and Multi-Stage Heat Pumps Gas, Electric or Oil Systems Millivolt Systems 2-wire Hydronic Systems AC or Hard-wired This thermostat is designed to work on the following supplies: Flat-head screwdriver, Small Phillips-head screwdriver, Hammer Electric drill and 3/16" bit, Three...
Owner's Manual - Page 6

DO NOT disconnect the wires from the existing thermostat before reading these instructions. The wires must be labeled prior to removal to ensure proper connection. 44002-01 r051807  RC Y G W RC Y G W w NOTICE OF CAUTION!
Owner's Manual - Page 8

...OFF at the furnace. (Failure to turn off the power to access the wires from the wall. (Some thermostats may be capped with an approved electrical connector, such as you disconnect them. Locate, but... to the HVAC system OFF at the main power panel or at the existing thermostat. Do not let the wires slip back into the wall during disconnection. You may have multiple covers, screws or...
Owner's Manual - Page 10

... life. Using the provided stickers, label each wire according to the existing terminal designation for proper identification. If wires marked "Y" or "C" are not labeled, contact a qualified HVAC technician. NOTE: Wire colors do not always comply with standards; Refer to the chart. If there is no "C" wire, the thermostat will run on battery power. 44002-01...
Owner's Manual - Page 11

... marked: CONVENTIONAL HVAC SYSTEMS label the wire with this sticker: if your existing thermostat is marked: label the wire with this sticker: Y1 / Y2 Cooling Stage 1 or 2 Y1 Y2 Y2 Y1 R/RC R / RC Cooling Transformer Power Supply ...24 VAC Common (if available) C G G Fan G RH RH Heating Transformer Power Supply RH See pages 72-73 for a complete wiring diagram. 10 44002-01 r051807
Owner's Manual - Page 12

... marked: HEAT PUMP SYSTEMS label the wire with this sticker: if your existing thermostat is marked: label the wire with this sticker: Y1 / Y2 Compressor Stage 1 or 2 Y1 Y2 Y2 Y1 C 24 VAC Common C C O W2 ... E R/RC R / RC 24 VAC Power Supply R/RC B B Heat Mode Powered Reverse Valve B L L System Monitor L See pages 74 for a complete wiring diagram. 44002-01 r051807 11
Owner's Manual - Page 14

... holes, visually level the wall plate and mark the wall for two holes. 44002-01 r051807 13 Remove the wall plate from the Hunter thermostat by gently pulling the wall plate from the back of the thermostat. 2. If the existing holes do not match those on the wall horizontally and pull the labeled...
Owner's Manual - Page 16

Tap the plastic anchors into the anchors. Insert the mounting screws through the wall plate opening. Reposition the wall plate on the wall, pulling the wires through the wall plate and into the holes until they are flush with the wall. 6. Verify that the wall plate is level. Remove the wall ...
Owner's Manual - Page 17

Terminal Shield Terminal Screw Jumper Wire 16 44002-01 r051807
Owner's Manual - Page 18

... the wall to prevent interference. 44002-01 r051807 17 Wrap the ends of any excess wire length back into the wall. Complete wiring diagrams for systems that do not remove the terminal screws. Insert wires behind the black terminal shield. otherwise, leave the jumper in electrical tape and carefully push them into the...
Owner's Manual - Page 22

GENERAL OPERATING INSTRUCTIONS Your new Hunter thermostat is a touch screen that you choose or you can also operate the thermostat manually. 44002-01 r051807 21 You can use . The front of the thermostat is easy to the pressure of a finger. You can program the thermostat to automatically readjust the temperature and airflow to settings that responds...
Owner's Manual - Page 31

... ON (Option 3) function runs only the fan during heating or cooling off cycles. USER SETTINGS The PERIODS PER DAY (Option 1) can be set to 0, the thermostat operates as a digital non-programmable...
Owner's Manual - Page 70

...there is closed properly. 5f. My system continues to protect the compressor. 5c. Make sure the thermostat is installed between the RC and RH terminals. 6. Replace unit. 44002-01 r051807 69 The display.... 7a. Replace batteries. 7. Wait. 5. If your system has 4 wires, ensure the jumper is not in the off to operate when the thermostat is in permanent override mode. 5b.
Owner's Manual - Page 72

Yes, visit us at 1-888-830-1326. 44002-01 r051807 71 The Hunter Technical Support is available from 7 am to 7 pm CST M-F and 8 am to 5 pm Saturday. Yes. Is there help on the web? Is there someone I can call? NEED MORE HELP? They may be reached toll-free at http://www.hunterfan.com for more information.
Owner's Manual - Page 73

... (single stage): RH, Rc/R (remove jumper between RH and RC/R), Y1, W1 G. • 2-wire Heat only (single stage): RH (jumper between RH and Rc/R), W1 • 3-wire Heat only (single stage): RH (jumper between RH and Rc/R), W1, G • 3-wire Cool only (single stage): RH (jumper between RH and Rc/R), Y1, G 72 44002...
Owner's Manual - Page 75

... Supply Compressor Compressor Auxiliary Emergency Reversing Valve Reversing Valve Fan System Stage 1 Stage 2 Heat Heat Cool Heat Control Monitor 24VAC Common (if available) Number of wires connected depends on systems without an...

Similar Questions

Hunter Wiring Diagram For Mod.44860
The heat mode will not go on. Please send proper wiring diagram.
(Posted by danmaria133 10 years ago)
Ask a New Question
Use the box below to post a new question about this Hunter product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Hunter Manuals

Find free Hunter 44860 manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Hunter Reviews

View thousands of Hunter user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Hunter customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Hunter customer service rankings, employee comments and much more from our sister site.

Hunter Recalls

Find comprehensive Hunter recall information updated hourly on RecallOwl.com.