Get support for Honeywell T8195B

Honeywell T8195B Support Question

Honeywell T8195B Support Question

Find answers below for this question about Honeywell T8195B.
Need a Honeywell T8195B manual? We have 2 online manuals for this item!
Question posted by Uktola on October 22nd, 2015

Heat And Cold Controls Are Off But Fans Won't Shut Off

heat and cold controls are at "off" but fans won't stop r

Current Answers

There are currently no answers that have been posted for this question.
Be the first to post an answer!

Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.

Related Honeywell T8195B Manual Pages

Owner's Manual - Page 1

Heating/Cooling Thermostat and Subbase or Heating or Cooling Thermostat and Wallplate T8195A,B/Q682 OWNER'S MANUAL 69-0563-2
Owner's Manual - Page 2

...-0563-2 at the end of automatic setback thermostats in a sealed tube. This thermostat meets California Title 24 requirements-mandatory installation of its useful life. Recycling Notice M3375 This control contains mercury in the trash. If this control, or an old control containing mercury in new heating and cooling systems. During heating and cooling, this manual to learn...
Owner's Manual - Page 4

..., right (red mark) controls the high temperature. 5 TIMER. time to control program index wheel. 4 1 2 3 M8723 4 69-0563-2 Controls high and low temperature at...pins. 9 PROGRAM PINS. Provides accurate room temperature reading. 4 TEMPERATURE SETTING LEVERS. Features Of Your Thermostat 1 FLIP-UP COVER. or p.m. Turn clockwise to hold the programming pins. 6 TIMER SETTING KNOB...
Owner's Manual - Page 5

... for program pin insertion. 11 MERCURY BULB AND BIMETAL ELEMENT (2). Located on and off. 12 WALLPLATE. Provide automatic temperature control by switching the heating or cooling system on 24-hour dial at 10-minute intervals for heating or cooling thermostat without system or fan switching. 5 69-0563-2 5 6 9 11 12 M8744 10 8 7 M8745 10 PIN SLOTS.
Owner's Manual - Page 6

Provides mounting base, wiring connections and manual switching control for heating/cooling thermostat. 13 R G FAN ON AUTO O B W Y HEAT COOL OFF M1551 6 69-0563-2 13 Q682 SUBBASE.
Owner's Manual - Page 8

Cooling system is Off. Heating system is Off. Both the heating and cooling systems are Off. The subbase fan switch controls fan operation as follows: HEAT-Heating system is controlled by the thermostat. Switch lever must stop in heating and cooling. If the fan switch is at the AUTO position, the fan is controlled by the thermostat in the detent over desired function indicator mark ...
Owner's Manual - Page 11

...-up to six temperature changes with your thermostat to automatically lower and raise the temperature one or more times every 24 hours. the blue pins start the high-temperature period; A heating program has been preprogrammed. You can set up cover and you'll find the 24-hour program dial. The red pins...
Owner's Manual - Page 12

...TEMPERATURE PIN IN TEMPERATURE PIN IN °F °C CONTROL °F °C CONTROL NIGHT BEGINS 58 14 BLUE 80 27 RED ENERGY 10...:00 PM SAVING ENDS 68 20 RED 75 24 BLUE PERIOD 6:00 AM DAY BEGINS 58 14 BLUE 80 27 RED ENERGY 7:30 AM SAVING ENDS PERIOD 4:00 PM 68 20 RED 75 24 BLUE 1 NOT APPLICABLE ON HEATING...
Owner's Manual - Page 14

... COOL position. 1 - Check for correct terminal hookups. May be out. May be traced to ON. Turn Off power to HEAT position. If blown or tripped, replace fuse or reset breaker. - R and W thermostat connections. Repair any frayed or broken wires. Turn On power. (continued) 14 69-0563-2 fuse or circuit breaker. Firmly tighten...
Owner's Manual - Page 15

May need more time to desired operating position. (continued) 15 69-0563-2 position of thermostat setpoint Reset to desired settings. Move to warm up at programmed time. 2 Temperature change occurs at the wrong time. - Troubleshooting (continued) Problem Check Action No heat (continued). - timer program for proper day or temperature program night phase. 12...
Owner's Manual - Page 16

thermostat circuits. Heating system should start . If the system does not operate, call a qualified technician. (continued) 16 69-0563-2 With system switch at HEAT, move temperature setting levers 5°F (3°C) below room temperature. Action HEATING...continued) Problem Room temperatures are not correct (continued). Heating system should start . If the systems do not ...
Owner's Manual - Page 17

Power. May be in OFF or HEAT position. - Action Move switch to cooling system. Turn Off power to COOL position... Contact a qualified service technician for correct terminal hookups. Make sure power is Off. fuse or circuit breaker. - Y and R thermostat connections. - Check for assistance. Make sure power is On. Repair any frayed or broken wires. Move to ON position. Firmly tighten...
Owner's Manual - Page 18

.... Refer to power clock. Timer does not run. - voltage across the C and R terminals. Remove the thermostat from the wallplate or subbase, and measure the voltage. Troubleshooting (continued) Problem Timer is losing time (continued). high limit control. Safety limit on equipment may be clogged. Check Action - If clock powered through system transformer, power...
Installation Instructions - Page 1

... transformer common is accessible for the Trained Service Technician. This thermostat is compatible with the system being controlled, the system will not be added to the thermostat control circuit. T8195B/Q682B,C, Y8224A Heating or Cooling and Heating/Cooling New Construction Thermostat, Wallplate and Subbase Installation Instructions for (DSI), Intermittent Pilot (IP), and...
Installation Instructions - Page 2

... supply to wall. 3 SCREW HOLES WITH PLASTIC ANCHORS O B R W G Y FAN ON AUTO HEAT COOL OFF HEATING/COOLING SUBBASE M1552A 3 SCREW HOLES WITH PLASTIC ANCHORS HEATING-ONLY WALLPLATE M857 69-0564-3 2 LOCATION Locate thermostat about 5 ft [1.5m] above the floor in these instructions carefully. IMPORTANT: This control requires an additional conductor to the subbase. 3. Carefully...
Installation Instructions - Page 3

... wires to prevent electrical shock or equipment damage. Firmly tighten the screws. Subbase (Heating/Cooling Systems) Refer to prevent drafts from affecting thermostat operation. EXISTING HORIZONTAL OUTLET BOX EXISTING HORIZONTAL OUTLET BOX R G FAN ON AUTO O B W Y HEAT COOL OFF HEATING/ COOLING SUBBASE M1553A R W VERTICAL OUTLET BOX 1 2 ADAPTER RING COVER PLATE 2 WALLPLATE M856...
Installation Instructions - Page 4

... batteries (not included) may be maintained across terminals R and C. B Heating damper or changeover/ reversing valve, makes continuously in the thermostat (Fig. 7). Install the batteries in heat. BATTERY LOCATION FOR (2) AAA BATTERIES; Subbase Terminal Control Function R Control transformer power. G Fan control circuit. The timer is interrupted due to power failure. Do...
Installation Instructions - Page 5

... system is controlled by the thermostat in the AUTO position, the fan is controlled by the plenum switch. Heating system is off . This will start when the furnace heats up. For proper circuit operation, switch lever must stop in the Owner's Manual. The fan will damage the heat anticipator. The subbase fan switch controls fan operation as follows: HEAT: Heating system is also...
Installation Instructions - Page 6

... may be built into the compressor control circuit. The fan will start . Push both temperature setting levers together at least 5° F [3° C] above room temperature. Allow for any test, refer to OFF. The cooling equipment and the fan should shut off . If thermostat fails any test, refer to manufacturer recommendations. HEATING/COOLING SYSTEM Turn on . Place...
Installation Instructions - Page 7

...FALL H C FALL SUBBASE SYSTEM SWITCH FAN SWITCH 2 FILTER LED HEAT OFF COOL ON AUTO HEAT OFF COOL CR B O G W Y X L1 (HOT) L2 HEATING COOLING FAN 1 DAMPER DAMPER RELAY HEAT RELAY COOLING RELAY 1 POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. 2 REMOTE INDICATION FOR FILTER OPTIONAL. Fig. 12-Typical hookup for T8195B Thermostat and Q682B Subbase in...

Similar Questions

Thermostat Replacemenmt
What is the honeywell replacement for thermostat T8195B?
(Posted by dmueller003 11 years ago)
Replacement For Honeywell Thermostat T8195b 1009
I am looking for replacement for honeywell thermostat t8195b 1009. The voltage to the thermostat is ...
(Posted by kjtriantafilo 12 years ago)
Ask a New Question
Use the box below to post a new question about this Honeywell product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Honeywell Manuals

Find free Honeywell T8195B manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Honeywell Reviews

View thousands of Honeywell user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Honeywell customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Honeywell customer service rankings, employee comments and much more from our sister site.

Honeywell Recalls