Get support for Honeywell RTH7600

Honeywell RTH7600 Support Question

Honeywell RTH7600 Support Question

Find answers below for this question about Honeywell RTH7600.
Need a Honeywell RTH7600 manual? We have 3 online manuals for this item!
Question posted by bogiug on August 24th, 2014

How To Wire Honeywell 7600d Heat Pump Aux

The person who posted this question about this Honeywell product did not include a detailed explanation. Please use the "Request More Information" button to the right if more details would help you to answer this question.

Current Answers

There are currently no answers that have been posted for this question.
Be the first to post an answer!

Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.

Related Honeywell RTH7600 Manual Pages

Owner's Manual - Page 2

It is Easy Label wires and remove your old thermostat Install and wire your new thermostat Set your new thermostat to match your heating/cooling system - This thermostat works with virtually all System Types - Installation is preset for wiring assistance before returning the thermostat to the store. 69-2206EF-01 ii Call 1-800-468-1502 for the most common system We are here to help.
Owner's Manual - Page 8

Have a Heat Pump system? See pages 22-23. CONVENTIONAL SCREW INSERT WIRES THEN TIGHTEN SCREWS LABELED WIRES CONVENTIONAL WIRE HOLE C W2 WY G G Y2 Y W RC R R M28070 Remove metal jumper if you have both R and Rc wires. See page 21. Call 1-800-468-1502 for wiring assistance. 69-2206EF-01  6 Connect Wires Simply match wire labels. Labels don't match? We are here...
Owner's Manual - Page 13

... is: q Multistage Heat and Cool q Heat Pump* without Backup Heat q Heat Pump* with Backup Heat q Heat Only q Cool Only Continue with advanced installation on 120/240 Volt systems. 11 69-2206EF-01 This thermostat works on 24 volt or 750 mV systems. It will NOT work on next page to match your thermostat to your system type. *Heat Pump-an air conditioner...
Owner's Manual - Page 15

SETUP WIRING ASybsotuetmyosuertunpew thermostat Step 1 Press System & Fan. RTH7600 0120 20 System & Fan Schedule Clock & More M27522 Step 2 Press and hold the center key until the screen changes (approximately 5 seconds). 0120 20 System Fan Done M27523 ASSISTANCE TROUBLESHOOTING 13 69-2206EF-01
Owner's Manual - Page 17

... two digits) Press s/t to change the last two digits of the year: 01 - 99 (i.e., 2001 - 2099) 0140 Month Setting Press s/t to page 16. SETUP WIRING RTH7600 ASybsotuetmyosuertunpew thermostat NOTE: If you set the time and date as shown on page 10, press NEXT to function 0170 and go to change the current month...
Owner's Manual - Page 18

...Function Settings & Options 0170 Select System Press s/t to navigate between functions. out central air conditioning. 6 Cool only: Central air condi- SETUP WIRING Advanced Installation Guide ASybsotuetmyosuertunpew thermostat See page 14 to select your system Type type: 1 Heat/cool: Gas, oil or electric heating with - tioning. 2 Heat pump: Heat pump with central air condi-
Owner's Manual - Page 19

... system (system controls fan operation). 1 Electric heat: Use this setting if you have an electric heating system (thermostat controls fan operation). 0190 Heat Pump Press s/t to select whether your Changeover changeover valve is used in heating Valve (for heat or cooling: pumps only) 0 Cooling changeover valve: Use this setting if you connected a wire labeled "O" to the O/B terminal (see page...
Owner's Manual - Page 20

SETUP WIRING Advanced Installation Guide ASybsotuetmyosuertunpew thermostat See page 14 to select your heating system: 9 Electric furnace: Electric heating systems. ...: Steam or gravity heat systems. 0270 Emergency Heat Cycle Rate (heat pumps only) Press s/t to navigate between functions. Function Settings & Options 0240 Heating Cycle Press s/t to select your heating Rate system: 5 Gas...
Owner's Manual - Page 21

...use the new 2007 DST calendar). Note: System maintains minimum 3°F difference between functions. ASSISTANCE TROUBLESHOOTING 19 69-2206EF-01 SETUP WIRING ASybsotuetmyosuertunpew thermostat RTH7600 See page 14 to navigate between heat and cool settings. 0320 Temperature Press s/t to set the temperature Format (°F/°C) display format: 0 Fahrenheit 1 Celsius 0330 Daylight...
Owner's Manual - Page 23

... R and Rc only if you must connect both R and RH wires, remove metal jumper. If your old thermostat had 2 C or C1 wires, wrap each separately with electrical tape and do not match terminals, connect wires as shown here (see notes, below). SETUP AWbiroiuntg-yocuornnveewnttiohnearml soyssttaetm RTH7600 Alternate wiring (conventional systems) If labels do not connect them.
Owner's Manual - Page 24

... opening. Match each other. 4. Use a screwdriver to each labeled wire with same letter on thermostat, see page 23. If E and Aux do not match letters on new thermostat. 2. Labels don't match? SCREW INSERT WIRES THEN TIGHTEN SCREWS LABELED WIRES HEAT PUMP WIRE HOLE HEAT PUMP C Aux Aux OYG G E Y L O/B RC R R M28104 ASSISTANCE TROUBLESHOOTING 69-2206EF-01 22...
Owner's Manual - Page 25

... Aux terminals do not each have a wire 6 connected, use a small piece of wire to connect them to the C terminal, stop now and contact a qualified contractor for heat pumps only) Leave metal jumper in place, connecting R & Rc terminals. If your old thermostat had both V and VR wires, stop now and contact a qualified contractor for help. SETUP WIRING Wiring-heat pump RTH7600 Alternate...
Owner's Manual - Page 26

... (see page 16). Heating system is running in emergency heat mode. It shows that the thermostat is set to make sure it is blank Make sure fresh AA alkaline batteries are properly installed (see page 16). SETUP WIRING Advanced Installation Guide Troubleshooting If you have difficulty with your heating and cooling equipment (see page 7). ASSISTANCE...
Owner's Manual - Page 27

... door is set higher not respond than the Inside temperature. Wait 5 minutes for the system to Cool. Press SYSTEM to set system to respond. SETUP WIRING Troubleshooting RTH7600 Heating or cool- "Wait" appears on . Heat pump is engaged.
Operation Manual - Page 2

...pending Copyright © 2013 Honeywell International Inc. Perchlorate Material-special handling may contain Perchlorate material. Need Help? Registered Trademark. All rights reserved. To prevent possible compressor damage, do not operate cooling system when outdoor temperature is below 50°F (10°C). This manual covers the RTH7600 model. (Pull thermostat from wallplate and turn...
Operation Manual - Page 5

Your new thermostat is pre-programmed and ready to bed at 10 pm To change, see pages 9-11 ONE-TOUCH TEMP CONTROL: You can override the program schedule ..., leave at 8 am, return at any time, and manually adjust the temperature (see pages 12-13). 3 69-2207ES-05 Select system setting: Preset to go . RTH7600 This thermostat is ready to Heat To change, see page 8 4.
Operation Manual - Page 7

... 6:01 AM Fan Auto Set To 75 Heat On Temperature setting System setting (see page 8) System & Fan Schedule Clock & Mode Fan setting (see page 7) M27526 Other display messages: • Cool On: Cooling system is activated • Heat On: Heating system is activated • Aux Heat On: Auxiliary heating system is activated (heat pump systems only) 5 69-2207ES-05
Operation Manual - Page 10

... the cooling system. • Auto: Thermostat automatically selects heating or cooling depending on how your thermostat was installed. 8 Compressor is locked out. Note: The Auto and Em Heat system settings may not appear, depending on the indoor temperature. • Off: All systems are off. • Em Heat (only for heat pumps with auxiliary heat): Thermostat controls Emergency and Auxiliary...
Quick Start Guide - Page 1

... OFF Cover MCR33835 M31545 Wire color might not match labels. Registered Trademark. © 2012 Honeywell International Inc. 69-2721-01 M.S. 05-12 Printed in a sealed tube. Press s or t to save and exit. 10:10 Done MCR33549 11 If your system type is... HEAT AUX. Quick Start Guide Touchscreen Programmable Thermostat RTH7600 Series 69-2721-01 5 Mount...
Quick Start Guide - Page 2

... stage (wire on Y). 10 Heat/Cool Multiple stages: 1 heat stage (wire on W), 2 cooling stages (wires on new thermostat. 2. Automatically turns on Heat or Cool based on thermostat, see Alternate wiring (heat pump system only). If E and Aux terminals do not match letters on room temperature. R OYG Rc 2 R 2 W Y G C 3 Y2 W2 MCR28076 Aux HEAT PUMP Aux E L MCR33552...

Similar Questions

Ask a New Question
Use the box below to post a new question about this Honeywell product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Honeywell Manuals

Find free Honeywell RTH7600 manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Honeywell Reviews

View thousands of Honeywell user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Honeywell customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Honeywell customer service rankings, employee comments and much more from our sister site.

Honeywell Recalls

Find comprehensive Honeywell recall information updated hourly on RecallOwl.com.