Question posted by cristiandorobantu on June 1st, 2012

Communication Rs 485 Problem

Good Morning,In one control acces system I have 8 PRO22IC cards. The cards have been parameterized identically (normal, except addresses). Four cards comunicates at level on bus RS485 and the other four no.Can you advice me what to try in order to have comunication on all 8 cards?Best regards, Cristian Dorobantu 

Current Answers

There are currently no answers that have been posted for this question.
Be the first to post an answer!

Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.

Related Honeywell PRO22IC Manual Pages

Installation Manual - Page 3

PRO-2200 Intelligent Controller PRO22IC Installation Guide 3 Contents Warnings and Cautions 4 Disclaimer...6 Unpacking Procedure 6 Shipping Instructions 7 Limited Warranty 7 Confidentiality ...8 Description ...9 Set Up ...9 LED Operation 10 Power...10 Communications 11 Alarm Inputs...12 Memory Backup Battery 12 Mounting Options 12 Suggested Installation Sequence 12 Specification ...
Installation Manual - Page 4

...using the PRO-2200 or related products for damages to the end user if a problem occurs. DO NOT ACCEPT VERBAL APPROVALS, THEY ARE NOT VALID. Engineered Systems Group ...as a primary warning or monitoring system. WARNING Fire Safety and Liability Notice Never connect card readers to the system. 4 Installation Guide PRO-2200 Intelligent Controller PRO22IC Warnings and Cautions WARNING ...
Installation Manual - Page 5

... integrated circuits and modules. Operation of this equipment in a residential area is subject to radio communications. NOTICE This document and the data in which case the user will be duplicated, used in a commercial environment. PRO-2200 Intelligent Controller PRO22IC Installation Guide 5 CAUTION IF ANY DAMAGE TO THE SHIPMENT IS NOTICED, A CLAIM MUST BE...
Installation Manual - Page 6

... other defect is noticed before unpacking, a claim must be filed with the acts or omissions of the equipment, if needed. 2. 6 Installation Guide PRO-2200 Intelligent Controller PRO22IC Disclaimer Product Liability; Unpacking Procedure CAUTION If any component thereof has caused personal injury or damage to the shipment is apparent, call 800-323-4576...
Installation Manual - Page 7

...number if the unit is not under normal use. All warranty work shall be...Communications Products and Upgrade kits is determined to Engineering Systems by Engineering Systems include a warranty registration card... RMA number on behalf of the problem or reason for shipment. Packages, ... SYSTEMS' PRODUCTS. PRO-2200 Intelligent Controller PRO22IC Installation Guide 7 Shipping Instructions To ship...
Installation Manual - Page 8

... the Products shall remain confidential and shall constitute proprietary rights of and only during the time it sells the Products. 8 Installation Guide PRO-2200 Intelligent Controller PRO22IC Confidentiality All software, drawings, diagrams, specifications, catalogs, literature, manuals and other party.
Installation Manual - Page 9

... configuration and card holders, and the event log buffer in FLASH memory and may be changed without physically changing board components. The program is stored in battery-backed memory. These jumpers/switches setup the memory chip size, port interface, end of line termination, controller address, and baud rate. PRO-2200 Intelligent Controller PRO22IC Installation Guide...
Installation Manual - Page 10

...Controller PRO22IC DIP Switch Settings: S8 S7 S6 S5 S4 S3 S2 S1 SELECTION OFF OFF OFF ON ADDRESS 1 OFF OFF ON OFF ADDRESS 2 OFF OFF ON ON ADDRESS 3 OFF ON OFF OFF ADDRESS 4 OFF ON OFF ON ADDRESS 5 OFF ON ON OFF ADDRESS 6 OFF ON ON ON ADDRESS 7 OFF OFF OFF OFF ADDRESS... FLASH FLASH FLASH DESCRIPTION Start Power-up sequence and normal operation. Flash when there is activity on Host Port...
Installation Manual - Page 11

... this port is selected as possible. Up to eight boards can be downgraded to eight controller boards can share one PRO22IC per port). Port 1 may use one of three communications specifications: RS-232-When this signal is RS-485. Install termination jumper only for port 1 is required and NOT optional. TXD indicatesTransmit and is set to...
Installation Manual - Page 12

... For N-485 Communication Connections, ...Controller PRO22IC For Wiring to the TR- GND is closed contact. The normal (non-alarm) condition is the signal ground. The wiring for the network. use as your data pair, observing polarity. When daisy-chaining RS-485...of the four corners of cabinet tamper and power fault monitoring. Use 24 AWG low capacitance, two twisted-pair, shielded...
Installation Manual - Page 13

...RS-485 (9,600 to PC, central station, modem or printer. 9. Setup the panel controls using the host software. Install the PRO22EN and/or PRO22M4 option boards per this board is being mounted in low voltage, class 2 circuit only. Connect communications... storage 0 to 85% RHNC PRO-2200 Intelligent Controller PRO22IC Installation Guide 13 Suggested Installation Sequence 1. WARNING: ...
Installation Manual - Page 14

... side ONLY! use as your data pair, observing polarity. 14 Installation Guide PRO-2200 Intelligent Controller PRO22IC Wiring Diagram Tamper Switch (In Close Position when Cabinet Door Is Closed) +12VDC Power Supply PWR + PWR - No Charging - RS 485 Com Bus Cable To Other Panel NC Note Connect to the appropriate earth ground on one side...

Similar Questions

Everyday At Same Time (afternoon) We Have To Give The Code In Order To Get Off T
Dear madam/sir,We use XK108 system since 8 years. We have changed the AC two weeks ago. We do not us...
(Posted by suleymankose 5 years ago)
How To Shut Off The Beep Sound When The Door Opens On My Fbii Xl Security Alarm
How do you shut off the beep sound that occurs when the door open opens but the alarm is no engaged ...
(Posted by sacsmom7 9 years ago)
Have A Old Honeywell/westinghouse Security System And It Keeps Beeping
HONEYWELL XL4600SM FLASHING AC/LB AND BEEPS EVERY 15 MINUTES OR SO, WHAT CAN I DO TO STOP IT?
(Posted by EMJWIN 12 years ago)
Ask a New Question
Use the box below to post a new question about this Honeywell product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Honeywell Manuals

Find free Honeywell PRO22IC manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Honeywell Reviews

View thousands of Honeywell user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Honeywell customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Honeywell customer service rankings, employee comments and much more from our sister site.

Honeywell Recalls

Find comprehensive Honeywell recall information updated hourly on RecallOwl.com.