Honeywell MS3000 Support Question
Find answers below for this question about Honeywell MS3000.Need a Honeywell MS3000 manual? We have 1 online manual for this item!
Question posted by deborah7 on September 17th, 2013
My Thermostat Will Not Respond To Any Of The Setting Buttons Even With A New Bat
Current Answers
Answer #1: Posted by KDG on September 20th, 2013 10:35 PM
If so you have both high voltage and the 24 volt control circuit power which is provided by the heater's transformer, the transformer receives the hot leg of the 24 volts and the Common terminal would be the opposite side of power for the 24 volt circuit, its called common as every 24 volt circuit terminates there to complete its circuit, common being the unswitched leg, red being the switched hot leg.
I suspect you have a 24 volt issue if the breakers are set to on, try resetting them even if they appear to be on.
You need to see if you have 24 volts by reading the red and comon terminals at the thermostats sub base or at the heater itself.;
By running the fan in the on position we are seeing if it has 24 volts power or not, if it does it haqs to havfe the high voltage as that is where its derived. I will furnish a few diagrams, ask further questions if required.
Supporting Image
You can click the image below to enlargeHVAC/R Journeyman with 37 years experience.
Related Honeywell MS3000 Manual Pages
Similar Questions
low battery keeps occurring even with new battery. Once low battery appears, heating system stops wo...
bat lo ,, does not reset with new batteries
My thermostat batteries died while away. I replaced them and it appears to be working but no matter ...
after putting i new batteries thermostat showa no numbers
Hi, I have a Honeywell RTH230B thermostat with new batteries but it doesn't display the flame symbol...