Hayward Power-Flo LX Support Question
Find answers below for this question about Hayward Power-Flo LX.Need a Hayward Power-Flo LX manual? We have 3 online manuals for this item!
Question posted by gol1950 on April 2nd, 2014
How Do You Prime A Haywardpower-flo Lx Pool Pump?
Current Answers
Answer #1: Posted by BusterDoogen on June 1st, 2014 9:02 AM
Priming Pump
Open all valves before starting system.
Release all air from filter and piping system. See filter owner’s manual.
When water source is higher than the pump, pump will prime itself when suction and outlet valves are opened. If water source is lower than the pump, unscrew and remove strainer cover; fill strainer and pump with water.
Clean and lubricate strainer cover O-ring with "Jack's 327" each time it is removed.
Clean and inspect O-ring; re-install on strainer cover.
Replace strainer cover on strainer housing; turn clockwise to tighten cover.
NOTE: Tighten strainer cover by hand only (no wrenches) ¼ turn. Pump should prime. Priming time will depend on vertical length of suction lift and horizontal length of suction pipe.
If pump does NOT prime within ten minutes, stop motor and determine cause. Be sure all suction and discharge valves are open when pump is running. See Troubleshooting Guide.
I hope this is helpful to you!
Please respond to my effort to provide you with the best possible solution by using the "Acceptable Solution" and/or the "Helpful" buttons when the answer has proven to be helpful. Please feel free to submit further info for your question, if a solution was not provided. I appreciate the opportunity to serve you!
Related Hayward Power-Flo LX Manual Pages
Similar Questions