Get support for Hayward EcoStar

Hayward EcoStar Support Question

Hayward EcoStar Support Question

Find answers below for this question about Hayward EcoStar.
Need a Hayward EcoStar manual? We have 3 online manuals for this item!
Question posted by dlesmash on September 13th, 2014

How To Control A Polaris With An Ecostar Pump

The person who posted this question about this Hayward product did not include a detailed explanation. Please use the "Request More Information" button to the right if more details would help you to answer this question.

Current Answers

There are currently no answers that have been posted for this question.
Be the first to post an answer!

Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.

Related Hayward EcoStar Manual Pages

EcoStar Manual - Page 17

Hayward EcoStar Pump SP3400VSP Thursday 1:27p 1725rpm 380 Watts Timer 1 timer will end at 11:45p
EcoStar Manual - Page 18

to adjust, > go to enter Use + / - Configuration Menu Locked Configuration Menu press > to next item Time: Th 1:27PM + change or > skip Set Day and Time Thursday 1:27p Speed Selection rpm MAX allowed speed 3450 (600-3450rpm) MIN allowed speed 600 (600-3450rpm) Set max-speed Prime Period: Auto Sense Remote Control Mode Standalone/Hayward Set COMM Bus Address Pool Filter
Technical Guide - Page 4

...Pools: When installing the EcoStar on existing pools..., care should be taken to equipment manuals for flow rates. 3" 184gpm 8fps 138gpm 6fps Figure 1 Page 2 MAXIMUM RECOMMENDED SYSTEM FLOW RATE BY PIPE SIZE 1.5" 2" 2.5" 51gpm 8fps 84gpm 8fps 120gpm 8fps 38gpm 6fps 63gpm 6fps 89gpm 6fps * Refer to insure the maximum flow does not exceed the capacity of pipe (L) between pump...
Technical Guide - Page 7

...pump. It is below high voltage wires and should be determined by the NEC and local code requirements. One for high voltage and the other for Canada). Voltage: 230 VAC, 60Hz, Single Phase. 2. Note: When connecting high voltage for an EcoStar... unit is data connected to a Hayward/Goldline control, voltage needs to come directly from a breaker in the control, or in the case of an OnCommand, ...
Technical Guide - Page 8

Reposition interface assembly as shown (fig 8). 3. Installation-Interface removal/positioning The interface assembly on the EcoStar can be configured in four different positions. 1. Remove the interface assembly as shown (fig 7, 9, 10 & 11) and re-secure with the two screws (fig 7). Remove the two screws as shown (fig 7). 2. Figure 7 Figure 8 Figure 9 Figure 10 Figure 11 Page 6
Technical Guide - Page 9

Installation-Interface /Wall mount 1. Plug is included with the EcoStar and includes blank cover, mounting bracket and new terminal block for wall mount or control connection. 2. Maximum 500‟ for data cable used for connecting to the interface (fig 12). 3. Figure 12 Figure 13 Figure 14 Page 7 After removal of ...
Technical Guide - Page 12

... OnCommand, directly from 4 on Remote display to 1 on the pump to 4 to the controller as they match point to 3 on the controller and 1 on 7 EcoStar is data connected to a Hayward/Goldline control, voltage needs to be different as those shown as long as shown (fig 22 & 23). Control Data Plug Software versions necessary to operate the...
Technical Guide - Page 13

... "line in" contacts on the Filter Pump Relay from a breaker in motor compartment. Pump power (230 VAC) needs to be rated for the pump (fig 24). Filter Pump Replay AUX Relay AUX Relay AUX Relay Fig 24 Page 11 Installation-Relay Connected Controls (Non Hayward/Goldline compatible software & third party controls) 1. The "Load Out" side will...
Technical Guide - Page 24

... v4.30 or higher will be set, as all settings will allow for the control of up to 8 EcoStars assignable to a Goldline/Hayward compatible software control pressing & buttons will only recognize address 1 (Pool Filter) and address 2 (Aux 1/ Spa Filter). Note: In the Hayward/Goldline compatible software mode the timers do not need to be handled...
Technical Guide - Page 25

... the button to continue. 16. Press the button to protect the drive . by pressing the & buttons.(fig 46). Enabling this feature will turn on the EcoStar, if stopped, to continue. Fig 46 Fig 47 Note: Low Temp operation is 1000 rpm (29%). Programming-Configuration 15. Setting will be asked to set...
Technical Guide - Page 26

... (fig 50). 19. There will be a screen telling you have an HCP3400VSP or HCP3400VSPVR commercial EcoStar please refer to page 39 for directions on the next screen. If yes, press and confirm on... setting password protection. At this page. 18. If the Relay Control or the Stand alone feature is being used the timer menus would like to reset to the ...
Technical Guide - Page 32

...stand alone mode. If the error message does not clear, cycle off the power to restart the pump. When the Low Temp Operation is activated you are using is an SVRS model and there is ...or more of the speed buttons or the quick clean button is running. 5. Operation 1. If the EcoStar you will go into the prime mode selected during operation Monday 1:30p 2500 RPM 2000 Watts Low ...
Technical Guide - Page 35

The wet end disassembly of the drive and motor area for this guide. Wiring Compartment Cover Interface Assembly Variable Speed Drive Figure 63 Motor/Fan Shroud Motor Page 33 Disassembly/Assembly This guide will only cover the disassembly of the EcoStar is exactly like the standard TriStar pump.
Technical Guide - Page 41

.... 2. At this screen (fig 77) after Low Temp Operation. Figure 77 Figure 78 Models HCP3400VSP and HCP3400VSPVR Figure 79 Page 39 If you have a commercial EcoStar you can enable or disable the Password Protection feature by pressing the & button.
Technical Guide - Page 43

... as the amount of time that can be used during troubleshooting. Status of the pump that has elapsed since the condition occurred. This menu provides important information about the performance of com link between VSC and Hayward control. Reads offline when not connected Event Log Press + to view information. Press the Menu...
Technical Guide - Page 46

... insure a good connection. Check to be between terminal 1 with EcoStar and terminal 4 with Hayward/Goldline Control (page 10). If no continuity. There should be sure motor ...If they are connected correctly (page 10). If pump is being controlled via data link to start the motor. Pump will attempt to a Hayward/Goldline Controller, disconnect the com ground wire between 0.5 and...
Technical Guide - Page 48

... v2.55 rev. 1.1. If the values are at "0" replace the interface. Control reads "Pool bridge comm" This indicates interference on the comm. Contact Clemmons Tech Service for isolator...pump drive. When it comes on, the pump will ramp up and down in speed. Troubleshooting/Fault Codes Code/Fault Indications Warning NO Comm Inspect the data wire between the control and EcoStar...
Technical Guide - Page 49

... connection and NOT the input connections for Standalone/Hayward. . Troubleshooting/Fault Codes Code/Fault Indications EcoStar is set to variable speed . The pump comes on the EcoStar is connected and configured to operate with the settings in the control (page 5). Be sure they are made to the line or load side of the filter...
Technical Guide - Page 50

... plumbing or other devices to come on the drive (page 10). The EcoStar is actually for relay control. Only the Stop/Resume and Menu button is sent to the pump, the EcoStar interface reads "Remote Stop Engaged". Try changing channel on the pump interface do not work properly. Remove wires and connect to the comm...
Parts Diagram - Page 1

... O-Ring) Strainer Cover Kit (Biguanide Sanitizer Applications Only; Pumps EcoStar™ SP3400VSP PUMP SERIES REPLACEMENT PARTS Parts for Pump Models: SP3400VSP, SP3400VSPVR 4 5 6 10 11 3... Motor Drive (Includes Digital Control Interface) Motor Drive, SVRS (Includes Digital Control Interface) Motor Drive Display Cover Motor Drive Wiring Cover Digital Control Interface Assembly Wall Mount Kit...

Similar Questions

Hayworc Ecostar Pump.'keypad Failed' Erroer Message
Pump display shows this message. Keypad failed. Hayword ecostar is3400vsp pump.
(Posted by Harenhema 10 years ago)
Hayward Ecostar Pump Manuel Is Incomprehensible
Is there a better alternative to the Ecostar Pump manual that comes with the pump. It is very diffic...
(Posted by sschenk3 10 years ago)
E-command 4 Control Of Ecostar 2 Stage Pump
diagram provided doesn't show control wiring between command module and pump, just that they are con...
(Posted by anderkin4 10 years ago)
How Do You Connect A Polaris Into A Hayward Ecostar Pump?
I replaced a old pool pump with a hayward ecostar pump and now need to reinstall my polaris booster ...
(Posted by gayethompson 11 years ago)
Ask a New Question
Use the box below to post a new question about this Hayward product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Hayward Manuals

Find free Hayward EcoStar manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Hayward Reviews

View thousands of Hayward user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Hayward customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Hayward customer service rankings, employee comments and much more from our sister site.

Hayward Recalls

Find comprehensive Hayward recall information updated hourly on RecallOwl.com.