Get support for Hayward Aqua Rite

Hayward Aqua Rite Support Question

Hayward Aqua Rite Support Question

Find answers below for this question about Hayward Aqua Rite.
Need a Hayward Aqua Rite manual? We have 6 online manuals for this item!
Question posted by Stephenmatus on May 7th, 2023

Aqua Rite Pro Sense And Dispense 'check System' Error.

Buttons are unresponsive. Tried unplugging to restart system to no avail. Please advise.

Current Answers

Answer #1: Posted by SonuKumar on May 7th, 2023 11:57 PM
SonuKumar

Member since:
May 9th, 2021

Points: 16,638,170
100
points
https://www.manualslib.com/manual/449889/Hayward-Aqua-RiteAnd-174.html?page=17#manual

The "Check System" error on a Hayward Aqua Rite or Aqua Rite Pro Sense and Dispense system is an indication that there is a problem with the system's sensors or wiring. Here are some steps you can take to troubleshoot the issue:

Check the salt cell: Make sure the salt cell is clean and free of debris. If the salt cell is dirty, it can cause inaccurate readings and trigger the "Check System" error.

Check the flow switch: The flow switch is designed to shut off the system if there is insufficient water flow. If the flow switch is malfunctioning or stuck, it can trigger the "Check System" error. Make sure the flow switch is clean and working properly.

Check the wiring: Check all wiring connections to ensure they are secure and free of corrosion. Loose or corroded connections can cause intermittent sensor readings and trigger the "Check System" error.

Check the sensor: If all wiring connections are secure, check the sensor for damage or corrosion. If the sensor is damaged or corroded, it may need to be replaced.


Please respond to my effort to provide you with the best possible solution by using the "Acceptable Solution" and/or the "Helpful" buttons when the answer has proven to be helpful.

Regards,
Sonu
Your search handyman for all e-support needs!!

Related Hayward Aqua Rite Manual Pages

AQ-RT-PRO Oct 08 & later - Page 4

The Aqua Rite Pro automatically sanitizes your pool. Dry acid can damage your authorized Goldline dealer. OPERATION The Aqua Rite Pro is an automatic chlorine generation system for pools up to 25,000 gallons (95,000 liters). The operation requires a low concentration of salt (sodium chloride) in a pool or spa using natural stone for coping or for other dispensing device ...
AQ-RT-PRO Oct 08 & later - Page 6

...Aqua Rite Pro and result in salt concentration. The only way to lower the salt concentration is unknown. This is common food quality or water softener salt and is usually available in feet/ gallons and meters/liters) if pool size is to partially drain the pool... to evenly disperse throughout the pool. Always check stabilizer (cyanuric acid), when checking salt. Salt Level Use the...
AQ-RT-PRO Oct 08 & later - Page 14

...AQL-CHEM sensing is pressed. It usually takes 2-3 adjustments to previous/next settings menu item Use this audible indication is higher than normal bather load or when your pool/spa and after...may need to lower the setting when the pool water temperature decreases significantly or there are three factors that entire volume of chlorine the Aqua Rite Pro will stay off until next time a ...
AQ-RT-PRO Oct 08 & later - Page 16

...Local and NEC codes. 120/240 VAC POWER AQUA RITEpro FROM FROM POOL SPA TO TO SPA POOL Preparing Pool/Spa Water Refer to the pool, per manufacturer's instructions. The pool's chemistry must be balanced BEFORE activating the Aqua Rite Pro. Do not mount Aqua Rite Pro inside the box), it is important not to the Aqua Rite Pro system. This ensures a quick, troublefree transfer to block...
AQ-RT-PRO Oct 08 & later - Page 17

...AQL-CHEM manual for information about available chlorinator cells. The electrolytic cell...pool and spa during spa spillover operation, but prevent overchlorination of the spa during "spa only" operation. If the switch is plumbed after (downstream) all the pool... line to the pool plumbing. The preferred installation is packaged with the local potable water supply. The Aqua Rite Pro is after the ...
AQ-RT-PRO Oct 08 & later - Page 18

... operating the spa only. IMPORTANT: If a dispensing device will be used for Canadian models only 15 Bonding lug to a circuit protected by a Ground Fault Circuit Breaker (GFCB). Refer to the pool bonding system. Tighten unions BY HAND for Canadian models). Input Power: Wire the Aqua Rite Pro to follow Local and NEC electrical codes. The Aqua Rite Pro is...
AQ-RT-PRO Oct 08 & later - Page 22

...dispensing. • pH Calibration Error -- If an ORP level of 950mV or higher is detected on the printed circuit board. • Check Flow Switch -- If a pH level of 6.9 or less is ORP Auto Sensing, the chlorinator has been turned off . Press the "+" button...-- • High Salt/Amps/Minerals -- The Aqua Rite Pro will stop generating chlorine under certain high salt conditions...
AQ-RT-PRO Oct 08 & later - Page 23

...ADVISED...to a pool or spa, war ...Pro Logic and E-Command pool automation products as well as its Aqua Trol chlorination products to be free of defects in materials and workmanship, under normal use and service for a period of the product. WARRANTY EXCLUSIONS: 1. If written proof of purchase is required for warranty service. Hayward/Goldline also warrants its Aqua Rite, Aqua Rite Pro, Aqua...
AQ-RT-PRO prior to Oct 08 - Page 4

... other restrictions. The actual amount of Pool and Spa Professionals (APSP). The Aqua Rite Pro can also control pH by The Association of chlorination required to properly sanitize a pool varies due to provide a fully integrated chemistry solution for pool or spa sanitation. With the AQL-CHEM installed, the Aqua Rite Pro senses the pool's ORP and pH levels and automatically...
AQ-RT-PRO prior to Oct 08 - Page 6

...pools, wait 10-14 days before adding salt to allow salt to pile up on the bottom of the Aqua Rite Pro...available in the pool and add salt according to the chart on and add salt directly into the pool...Always check stabilizer (cyanuric acid), when checking ...the pool. Gallons (pool size in feet) Rectangular Length x... Liters (pool size in feet/ gallons and meters/liters) if pool size is ...the pool and ...
AQ-RT-PRO prior to Oct 08 - Page 14

...menu item (config. filter run time each day. If optional AQL-CHEM sensing is usually not a problem because bacteria and algae stop growing at this...approximately 50%. The Aqua Rite Pro automatically stops generating when the pool water temperatures drops below 50ºF. the desired output % setting or ORP setting (when using the Super Chlorinate function for your pool/spa and after the...
AQ-RT-PRO prior to Oct 08 - Page 17

... 2" (51mm) PVC pipe. To ensure proper operation, verify that the Aqua Rite Pro installation does not constitute a cross connection with 1½" (38 mm) plumbing. The electrolytic cell and flow switch tee fitting are designed to allow for chlorination of both the pool and spa during spillover but prevent overchlorination of water flow. If the switch...
AQ-RT-PRO prior to Oct 08 - Page 22

... Aqua Rite Pro will stop generating chlorine under certain high salt conditions in order to reset the alarm and resume chlorination. • Ambient Sensor -- if no cell is detected on the printed circuit board. • Cell Missing -- if the chlorinator is enabled but no chlorinator cell power is detected. • CSM Comm Error: -- Check Feeder -- Check...
AQR - Page 6

...the loss of soda, salt with 3200 ppm being optimal. Always check stabilizer (cyanuric acid), when checking salt. Salt is no main drain) to allow the plaster to...salty taste to your pool/spa is usually available in 40-80 lb. A high salt level can cause the Aqua Rite® to shutdown and may take longer for 24 hours with fresh water. Gallons (pool size in feet) Rectangular...
AQR - Page 11

... to a pool automation control (Goldline Pro Logic, Pentair Intellitouch or Polaris Eos): The Aqua Rite is designed to the other pool equipment. The Pro Logic, Intellitouch...Aqua Rite chlorinator will be lowered accordingly. the "Desired Output %" setting 3. The Aqua Rite® will generate: 1. After you inspect the cell (and clean, if necessary) press the small "diagnostic" button...
AQR - Page 18

... Cell has been selected (page 7). If the cell is too low. - Aqua Rite® switch in pool/spa. Low stabilizer (Cyanuric Acid). - Filter pump time too short (8 hours for average size pools, more for large pools) - Salt level too low (below 50ºF) causes Aqua Rite to "normal" and chlorine tests will use chlorine at recommended levels. 6. Very...
AQR - Page 19

...AND OTHER ADDITIONAL EXPENSES, EVEN IF THE SELLER HAD BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. FOR THE ABOVE-IDENTIFIED...APPLY TO YOU. Damage resulting from failure to a pool or spa, war or acts of three (3) years. Problems ... AND MATERIAL RATES. 16 Hayward/Goldline also warrants its Aqua Rite, Aqua Rite Pro, Aqua Plus and SwimPure chlorination products to install, operate or maintain...
Aqua Rite & Aqua Rite XL - Page 6

...available in 40-80 lb. The salt in low chlorine production. This loss is due primarily to the addition of water because of splashing, backwashing, or draining (because of the Aqua Rite® and result in your pool...salty taste to your pool/spa is to partially drain the pool and refill with anti... fresh water. Always check stabilizer (cyanuric acid), when checking salt. Run the filter...
Aqua Rite & Aqua Rite XL - Page 10

... Refer to the Water Chemistry section for your pool/spa and after that all pool automation controls. filter time each day. Most pools require less chlorine during cold weather and the ... small button next the display once. The Aqua Logic, Intellitouch or Eos can control which directly contribute to grams/liter. The Aqua Rite automatically stops generating when the pool water ...
Aqua Rite & Aqua Rite XL - Page 18

... residual - ally checked. 5. Aqua Rite® switch in pool/spa. Filter pump time too short (8 hours for average size pools, more for 3 seconds to stop the "Inspect Cell" LED flashing. 7. "Yellow Out" or similar treatment recently used. 4. "Check Salt" LED illuminated or flashing Check salt level in OFF position. - nostic" button for large pools) - It still...

Similar Questions

Aqua Rite Pro 'check System' Only Light.
I have an Aqua Rite Pro and the "Check System" LED is lit. There are no other error codes present. H...
(Posted by stlcardsfan389 2 years ago)
How To Fix Ecostar Comm Bus Offline & Pro Logic Vsp Comm Error?
I cannot get my Hayward Pro Logic board to communicate with my Hayward Ecostar VSP pump. The pump sa...
(Posted by m72422 7 years ago)
Ask a New Question
Use the box below to post a new question about this Hayward product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Hayward Manuals

Find free Hayward Aqua Rite manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Hayward Reviews

View thousands of Hayward user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Hayward customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Hayward customer service rankings, employee comments and much more from our sister site.

Hayward Recalls

Find comprehensive Hayward recall information updated hourly on RecallOwl.com.