Question posted by acpcpayments on April 19th, 2023

Aqua Rite Error Code

Code on led screen is Hoe what does this mean

Current Answers

Answer #1: Posted by SonuKumar on April 19th, 2023 8:54 PM
SonuKumar

Member since:
May 9th, 2021

Points: 16,638,180
100
points
If your Hayward Aqua Rite control panel is displaying the code "HOE" on the LED screen, it means that the system has detected an issue with the flow sensor.

The flow sensor is a component of the Aqua Rite system that monitors the flow rate of water passing through the system. If the system detects a problem with the flow sensor, it will display the "HOE" error code.

Here are some steps you can take to troubleshoot the issue:

  1. Check the flow sensor for any visible damage or corrosion. If the sensor appears damaged, it may need to be replaced.
  2. Verify that the flow sensor is properly installed and connected. Make sure that the sensor is aligned with the flow of water and that the connections are tight and secure.
  3. Check the wiring and connections between the flow sensor and the Aqua Rite control panel. Make sure that all wires are connected properly and that there are no signs of damage or corrosion.
  4. Reset the system by turning off power to the Aqua Rite control panel, waiting a few minutes, and then turning the power back on. This may help reset the system and clear any error codes.

If these steps do not resolve the issue, you may need to contact a qualified pool technician or Hayward customer support for further assistance.


Please respond to my effort to provide you with the best possible solution by using the "Acceptable Solution" and/or the "Helpful" buttons when the answer has proven to be helpful.

Regards,
Sonu
Your search handyman for all e-support needs!!

Related Hayward Aqua Rite Manual Pages

AQ-RT-PRO Oct 08 & later - Page 2

...- To reduce the risk of electric shock, this terminal must be connected to the grounding means provided in the electric supply service panel with a continuous copper wire equivalent in accordance with ...Canadian models) of electrical equipment, metal water pipe, or conduit within 3 meters of the pool, spa or hot tub shall be used only in size to the circuit conductors supplying the equipment....
AQ-RT-PRO Oct 08 & later - Page 6

... conditioning salt pellets, however, it will reduce the efficiency of the Aqua Rite Pro and result in 40-80 lb. Type of rain). Run the filter pump for them to dissolve. These levels will begin to give a salty taste to your pool/spa is constantly recycled and the loss of salt throughout the swimming...
AQ-RT-PRO Oct 08 & later - Page 14

... to Default Press + Are you can control which directly contribute to the amount of chlorine the Aqua Rite Pro will automatically turn off until next time a key is selected, then the backlight will generate...longer to raise the setting when the pool water temperature increases significantly, when there is higher than normal bather load or when your pool/spa and after the last key is pressed ...
AQ-RT-PRO Oct 08 & later - Page 16

... be performed in a raintight enclosure that is suitable for recommended chemical levels. Mounting the Aqua Rite Pro Control The Aqua Rite Pro is contained in accordance with Local and NEC codes. 120/240 VAC POWER AQUA RITEpro FROM FROM POOL SPA TO TO SPA POOL Preparing Pool/Spa Water Refer to mount horizontally on a flat surface with the knockouts facing downward. INSTALLATION...
AQ-RT-PRO Oct 08 & later - Page 17

... ensure proper operation, verify that the Aqua Rite Pro installation does not constitute a cross connection with a flow switch and cell unions. Consult local plumbing codes. Plumbing Ensure that the arrow on... counted as running the plumbing lines from the AQL-CHEM's probe cell to the pool/spa. Alternate configurations #1 shows the flow switch can also be plumbed into consideration the ...
AQ-RT-PRO Oct 08 & later - Page 18

... a Ground Fault Circuit Breaker (GFCB). Input Power: Wire the Aqua Rite Pro to the LOAD SIDE of both the pool and spa during spillover but preventing overchlorination when operating the spa only. It is attached to pool bonding system Refer to follow Local and NEC electrical codes. IMPORTANT: If a dispensing device will be bonded with the configuration...
AQ-RT-PRO prior to Oct 08 - Page 6

...not lost due to evaporation. A low salt level will begin to give a salty taste to your pool/spa is between 2700-3400 ppm (parts per million) with fresh water. Salt is also acceptable to use...low chlorine production. If the level is low, determine the number of the Aqua Rite Pro and result in the pool and add salt according to determine how much salt in salt concentration. Turn ...
AQ-RT-PRO prior to Oct 08 - Page 14

... find the ideal setting for your pool/spa and after the last key is NOT reversible--be careful Operation Assuming that the water chemical levels are in the pool The filter pump timer should only take minor, infrequent adjustments. The Aqua Rite Pro automatically stops generating when the pool water temperatures drops below 50ºF. This...
AQ-RT-PRO prior to Oct 08 - Page 16

... inside the box), it is designed to mount horizontally on a flat surface with Local and NEC codes. 120/240 VAC POWER AQUA RITEpro FROM FROM POOL SPA TO TO SPA POOL Preparing Pool/Spa Water Refer to the Aqua Rite Pro system. NOTE: If the pool does not have new water, add 1 quart (1 liter) of metal remover and 1 quart (1 liter) of...
AQ-RT-PRO prior to Oct 08 - Page 17

...pool and spa during spa spillover operation, but preventing overchlorination when operating the spa only. 14 Refer to be at least a 12" (25cm) straight pipe run before (upstream) the flow switch. Plumbing Ensure that the arrow on the flow switch (located on page 13. Consult local plumbing codes... ensure proper operation, verify that the Aqua Rite Pro installation does not constitute a cross...
AQR - Page 6

... determine how much salt in your pool (generally, the salt will reduce the efficiency of the pool. Turn the circulating pump on the bottom of the Aqua Rite® and result in the pool and add salt according to the ... iodized salt. A low salt level will begin to give a salty taste to your pool/spa is also acceptable to use rock salt, salt with yellow prussiate of salt throughout the ...
AQR - Page 11

.... The Aqua Rite salt display and LED indicators operate as normal, but the main switch and "Desired Output %" dial are long periods of chlorine the Aqua Rite will generate: 1. The Pro Logic, Intellitouch or Eos can override this by switching to the pool automation control instructions for your pool/spa and after approximately 500 hours of the Aqua Rite "Desired...
AQR - Page 13

...) horizontal distance (or more, if local codes require) from inside a panel or tight enclosed area. 10 Because the enclosure also acts as a heat sink (disperses heat from the pool/spa. The control is suitable for recommended chemical levels. INSTALLATION Installation must be balanced BEFORE activating the Aqua Rite®. The control must be mounted a minimum...
AQR - Page 14

...pool and spa during spillover but prevent overchlorination of the spa during spa spillover operation, but preventing overchlorination when operating the spa only. 11 Consult local plumbing codes. The cell must be plumbed in the return line to the pool/spa... pool/spa combination systems with the local potable water supply. The Aqua Rite is plumbed after (downstream) all the pool ...
AQR - Page 18

... levels. 6. Call for large pools) - Check salt level in pool/spa. "High Salt" LED illuminated Be sure that the correct...LED flashing. 7. Salt level too low (below 50ºF) causes Aqua Rite to have your salt level professionally checked. 5. Inspect and clean cell according to stop generating (Generating LED flash- If the pool has the proper amount of days before the pool...
Aqua Rite & Aqua Rite XL - Page 6

... salt, salt with 3200 ppm being optimal. A low salt level will begin to give a salty taste to your pool/spa is greater than 99% pure. Type of the Aqua Rite® and result in the pool and add salt according to dissolve. It is to cure. Brush the salt around to speed up on the...
Aqua Rite & Aqua Rite XL - Page 10

...for your pool/spa and after that the water chemical levels are in the pool passes through the filter each day (hours) 2. filter time each day. For pools with ...Aqua Rite will not function when the Aqua Rite is being controlled by switching to AUTO. Most pools require less chlorine during cold weather: Check chlorine levels periodically. The "Remotely Controlled" LED on the Aqua Rite...
Aqua Rite & Aqua Rite XL - Page 12

... from the pool/spa. NOTE: If the pool does not have new water, add 1 quart (1 liter) of metal remover and 1 quart (1 liter) of 5 ft. (2 meters) horizontal distance (or more, if local codes require) from inside a panel or tight enclosed area. 9 The control must be balanced BEFORE activating the Aqua Rite®. Do not mount Aqua Rite inside the...
Aqua Rite & Aqua Rite XL - Page 13

...the Aqua Rite® installation does not constitute a cross connection with 1½" (38 mm) plumbing. Adapters (not included) can be at least a 12" (25cm) straight pipe run before (upstream) the flow switch. Configurations #2 and #3 allow chlorination of the spa during spa spillover operation, but preventing overchlorination when operating the spa only. 10 For pool/spa combination...
Aqua Rite & Aqua Rite XL - Page 18

... Check salt level in OFF position. - If the cell is still illuminated, the cell may be worn and need replacement. 8. Aqua Rite® switch in pool/spa. Cold water (below 2400 ppm, Check Salt LED on cell. - "Yellow Out" or similar treatment recently used. A possible Printed Circuit Board fault has been detected. If salt level...

Similar Questions

How Do You Change Hayward Aqua Rite Chlorinator From C To F
how do you chnage hayward aqua rite chlorinator to Ferihiet from ceseles
(Posted by mills13 1 year ago)
Error Code Xx, How Do I Fix It?
New pump worked yesterday not working today, error code is XX.
(Posted by mlgaudette 7 years ago)
Goldline Aqua Rite Not Reading Salt Level Properly
I have an aqua rite salt generation system in my pool. The digital display is reading 2100 for sal...
(Posted by bpark 11 years ago)
Ask a New Question
Use the box below to post a new question about this Hayward product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Hayward Manuals

Find free Hayward Aqua Rite manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Hayward Reviews

View thousands of Hayward user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Hayward customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Hayward customer service rankings, employee comments and much more from our sister site.

Hayward Recalls

Find comprehensive Hayward recall information updated hourly on RecallOwl.com.