Answer #1: Posted by linkshahzad on July 23rd, 2013 1:39 AM
This answer was accepted by the poster of the original question.
linkshahzad

Member since:
June 12th, 2013

Points: 60,030
1,100
points
E0 is usually code for power issues. The fact it comes on and goes off is reminiscent of a motor heater or overloads. They auto magically reset when the motor cools down. If you have a prob., in the motor it will cool down turn on heat up turn off. About 15-20 cycles. I can advise to start cheap and work your way up. Replace the capacitor which will be mounted on or very close to it. 2 wires going to a silver mini flask looking device. Careful a capacitor will charge up energy and hold until discharge. Before anything cut power to the unit the using a small jumper wire touch each end to each terminal tab causing a short and it will de-energiz. Remove the wires from the device and loosen the holding strap. Take it to a motor shop and get a new one 5-10 bucks at most. Replace the device {don't worry about what wire goes where its in series and AC} Try it again. If this doesn't work then its decision time. Technician or take motor for testing? Cost very close. Good Luck

Related Haier HDU-42HA03 Manual Pages

User Manual - Page 1

DUCT TYPE AIR CONDITIONER Operation & Instruction Manual AD242AMBEA(ECO) AD28NAMBEA(ECO) AD36NAMBEA(ECO) AD42NAMBEA(ECO) No. 0010577352 Please read this manual carefully and safely. Please keep this operation manual before using the air conditioner.
User Manual - Page 3

... into operation. All these valuable materials may be taken to environmental awareness by yourself. Damaged air conditioners are not to the assembly, operation and maintenance of the air conditioner. Cautions Disposal of the old air conditioner Before disposing an old air conditioner that goes out of polyethylene and the polyethylene foam pads contain no case should children be...
User Manual - Page 4

...be connected to a gas pipe, city water pipe, lightning conductor rod or grounding cable of air conditioner. Bodily injury could result by a collapse. CAUTIONS FOR OPERATION You should not be necessary....a grave result like . However, even if precautions are shown in the column of air conditioner. Grounding cable should be arranged to provide a positive draining. If you need some ...
User Manual - Page 5

...is relocated, contact your dealer. Do not use a fuse of combustible gas or liquid near the air conditioner or to use such equipment as a flower vase, etc. around the indoor unit or the ...Improper practice of falling or injury by collapsed object. Neither stand on the air conditioner nor place something on it could cause water leakage, electric shock or fire. 4 It ...
User Manual - Page 6

... 3mm. 7. and the distance between its service agent or a similar qualified person. 3. Safety Precautions The machine is adaptive in line with the type of the air conditioner should be in following situation 1. The indoor unit installation height is damaged, it with the local wiring standard. 5. Applicable ambient temperature range: Cooling Heating Indoor...
User Manual - Page 7

Parts and Functions Air outlet Air inlet AD242AMBEA(ECO) AD28NAMBEA(ECO) Air outlet Air inlet AD36NAMBEA(ECO) AD42NAMBEA(ECO) 6
User Manual - Page 8

... heating operation Isn't it warming up? left open? heating load generated? When the air conditioner does not operate properly after you have checked the above mentioned items or when the ... Cooling or heating is horizontal, the blow wind does not reach floor. exist at the air inlet or outlet? Isn't the swing louver horizontal? (At HEATING mode) If swing louver is not...
User Manual - Page 9

... to the FAN mode but it is the flowing sound of plastics. In this case consult sales dealer for (During this time air conditioner operates in fan three minutes mode.) Air does not blow or the fan speed can not be changed over automatically. To prevent frost from the outdoor unit during cooling...
User Manual - Page 10

... the power supply switch. Electric power is consumed even the air conditioner is not dirty. Make sure that there are no obstacles blocking the air inlet and air outlet of the unit well. If it in the power... supply switch 12 hours before starting run the air conditioner without the air filter. Stop operation and turn off the detergent using clean water. Cut in...
User Manual - Page 11

... to stop under low temperature condition of indoor heat exchanger. When room temperature decreases, air conditioner automatically changes over to the ordinary heating mode. Defrosting operation When a room is stopped...in the following cases. the heating operation is warmed with a heat pump type air conditioner, frost accumulates on the heat exchanger of outdoor unit along with the help of...
User Manual - Page 12

... service is used , and so in accordance with the hot air or noise. Install the air conditioner firmly on the authorized engineer with qualification for safe and comfortable ... Installed Correctly Confirm the following special place. Installation place Avoid installing the air conditioner Install the unit at the following items for electric work and grounding work...
User Manual - Page 13

...case, important safety related information is a concern about leakage of the air conditioner, do not mix air etc. In regards to the terminal connection part, through properly securing it...malfunction. Improper placement of this company can result in electric shock. When a large air-conditioning system is insufficient, injury can sufficiently support heavy weight. When strength is ...
User Manual - Page 14

... pay sufficient attention to your local distributor. When the installation height exceeds 3m warmed air stays close to oil splashes or steam (e.g. These instructions do not cover all variations ...for installation satisfying following height. In such cases, suggest your client users to install air circulators. (b) Places where perfect drainage can be referred to the prevention of dewing...
User Manual - Page 16

... that the relation between the lower surface of the unit proper and water level in a downhill grade (1/50~1/100) and avoid riding across an elevation Air vent Keep free from factory.
User Manual - Page 17

... (8) Connection of suction, exhaust ducts State seeing from top of 1/100 or more VP 30 Air conditioner main unit Ceiling surface B Special blowout (Option) Heat insulation inlet duct (optional or marketat item...standard specifications. Reduce the length of indoor placement. (f) Do not ever provide an air vent. (g) Avoid positioning the drain piping outlet at less than 2:1. Do not ...

Similar Questions

Commercial Cool Air Conditioner Model# Cwh12a
Where can I purchase a new Commercial Cool air conditioner from?
(Posted by williamsshannon984 2 years ago)
Air Conditioner Wont Turn On. It Worked Just Fine Two Days Ago
I have a Haeir air conditioner HPAC9M two days ago it worked fine but now it wont turn on
(Posted by alexisiam 3 years ago)
Portable Air Conditioner Keeps Shutting Off
my portable air conditioner keeps shutting down after running for about 10 min
(Posted by Buttercup2 6 years ago)
Haier Esa412r Air Conditioner Bd Noise Rating
what is the db noise rating for the haier esa412r window air conditioner ar various fan speeds
(Posted by Wfrooney 7 years ago)
My Air Conditioner Go Off
when the air conditioner is funtion for only little time like 20 minute is going to signal the STOP ...
(Posted by haydeejose 7 years ago)
Ask a New Question
Use the box below to post a new question about this Haier product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Haier Manuals

Find free Haier HDU-42HA03 manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Haier Reviews

View thousands of Haier user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Haier customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Haier customer service rankings, employee comments and much more from our sister site.

Haier Recalls

Find comprehensive Haier recall information updated hourly on RecallOwl.com.