Get support for Haier AV16NMVERA

Haier AV16NMVERA Support Question

Haier AV16NMVERA Support Question

Find answers below for this question about Haier AV16NMVERA.
Need a Haier AV16NMVERA manual? We have 1 online manual for this item!
Question posted by erwin70184 on January 3rd, 2014

I Need To Replace Two Compressors Please Forward Me Details Of Supplier.

The person who posted this question about this Haier product did not include a detailed explanation. Please use the "Request More Information" button to the right if more details would help you to answer this question.

Current Answers

There are currently no answers that have been posted for this question.
Be the first to post an answer!

Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.

Related Haier AV16NMVERA Manual Pages

Design Manual - Page 7

... Capacity,10=10HP Product type : "V" stands for MRVII R410A outdoor Indoor unit: Model: A B 09 2 M C E R A Haier Air Conditioner Climate type: T1 Design number: A stands for fixed frequency type, H stands for inverter type, R stands for DC inverter and R410A type ...stands for duct type, "S" stands for wall mounted type, "F" stands for console type Haier Air Conditioner G R U P A d.o.o. 07
Design Manual - Page 9

... shall have the multi-step of capacity control to follow variation in part is made of Aluminum. Features 5.1 Adopt the high efficiency compressor The compressor is high efficiency and low noise. Compressor shall be equipped with heat expelling fan to reduce the electric control box temperature and keep the electric safe. 09 G R U P A d.o.o. Stable...
Design Manual - Page 11

... electrical and electronic equipment. single way total pipe length can be environmental for every air conditioning manufacturer. Auto restart function The unit has memory function, when the power is...25 16HP COP 3.90 EER 3.20 Cooling operation condition: indoor temp is error such as compressor wiring, sensor, communication etc., the PCB will run as the previous state. 5.10 Reliable ...
Design Manual - Page 12

...concealed type < Med static pressure duct type < High static pressure duct type < Wall mounted type < Console type 12 G R U P A d.o.o. High efficiency compressor The compressor is with brushless internal motor, which runs faster, much more stable. Furthermore, the compressor is hermetically scroll type with the protection when temperature, current etc occur error. 5.11 Super comfortable a.
Design Manual - Page 31

...HNB71FB-YJHC, Mitsubishi Electric oil type MEL32 oil charging amount 3 litre with compressor, additional charging 1 litre to gas-liquid segregator G R U P ...) Heating capacity at low temp.(kw) Output power of outdoor motor(KW) Exterior dimensions (mm) Weight (Kg) Exterior colour Compressor type Outdoor airflow (m3/h) Refrigerant (R410A) charge (Kg) 8 AV08NMVERA ** 22.6 25.0 21.2 3N~, 380~400V,...
Design Manual - Page 32

... capacity(KW) Nominal heating capacity(KW) Heating capacity at low temp.(kw) Output power of outdoor motor(KW) Exterior dimensions (mm) Weight (Kg) Exterior colour Compressor type Outdoor airflow (m3/h) Refrigerant (R410A) charge (Kg) 12 AV12NMVERA ** 33.5 37.5 28.7 3N~, 380~400V, 50Hz 14.2/17.0 8.58/10.3 15.1/18.4 9.1/11.3 7.55...
Design Manual - Page 33

... capacity(KW) Heating capacity at low temp.(kw) Output power of outdoor motor(KW) Exterior dimensions (mm) Weight (Kg) Exterior colour Compressor type Outdoor airflow (m3/h) Refrigerant (R410A) charge (Kg) 16 AV16NMVERA ** 45.0 50.0 39.1 3N~, 380~400V, 50Hz 23.2/28.1 14.06/17.0 21.2/25.6 12.82/15.38 10.28...
Design Manual - Page 35

... power of outdoor motor(KW) 14.28 1.8 16.38 1.8 Exterior dimensions (mm) 990*750*1750+1390*750*1750 990*750*1750+ Weight (Kg) Exterior colour Compressor model Outdoor airflow (m3/h) Refrigerant (R410a) charge (Kg) Gas piping(mm) 510 ivory scroll 22000 22 28.58 1390*750*1750 510 ivory scroll 22000...
Design Manual - Page 36

... capacity(KW) Nominal heating capacity(KW) Heating capacity at low temp.(kw) Output power of outdoor motor(KW) Exterior dimensions (mm) Weight (Kg) Exterior colour Compressor type Outdoor airflow (m3/h) Refrigerant (R410A) charge (Kg) Gas piping(mm) Liquid piping(mm) Equipoise/Oil equalization piping(mm) Noise level(dB(A)) 26 AV26NMVERA AV10...
Design Manual - Page 37

... capacity(KW) Nominal heating capacity(KW) Heating capacity at low temp.(kw) Output power of outdoor motor(KW) Exterior dimensions (mm) Weight (Kg) Exterior colour Compressor type Outdoor airflow (m3/h) Refrigerant (R410A) charge (Kg) Gas piping(mm) Liquid piping(mm) Equipoise/Oil equalization piping(mm) Noise level(dB(A)) 30 AV30NMVERA AV14...
Design Manual - Page 38

... capacity(KW) Nominal heating capacity(KW) Heating capacity at low temp.(kw) Output power of outdoor motor(KW) Exterior dimensions (mm) Weight (Kg) Exterior colour Compressor model Outdoor airflow (m3/h) Refrigerant (R410a) charge (Kg) Gas piping(mm) Liquid piping(mm) Equipoise/Oil equalization piping(mm) Noise level(dB(A)) 34 36 AV34NMVERA...
Design Manual - Page 39

... capacity(KW) Nominal heating capacity(KW) Heating capacity at low temp.(kw) Output power of outdoor motor(KW) Exterior dimensions (mm) Weight (Kg) Exterior colour Compressor type Outdoor airflow (m3/h) Refrigerant (R410A) charge (Kg) Gas piping(mm) Liquid piping(mm) Equipoise/Oil equalization piping(mm) Noise level(dB(A)) 38 AV38NMVERA AV10...
Design Manual - Page 40

... capacity(KW) Nominal heating capacity(KW) Heating capacity at low temp.(kw) Output power of outdoor motor(KW) Exterior dimensions (mm) Weight (Kg) Exterior colour Compressor model Outdoor airflow (m3/h) Refrigerant (R410a) charge (Kg) Gas piping(mm) Liquid piping(mm) Equipoise/Oil equalization piping(mm) Noise level(dB(A)) 42 44 AV42NMVERA...
Design Manual - Page 41

....6/76.8 37.33/44.86 38.46/46.14 30.21 30.84 3.3 3.3 (1390*750*1750)*3 (1390*750*1750)*3 Piping dimension Weight (Kg) Exterior colour Compressor model Outdoor airflow (m3/h) Refrigerant (R410a) charge (Kg) Gas piping(mm) Liquid piping(mm) Equipoise/Oil equalization piping(mm) Noise level(dB(A)) 875 36000 44...
Design Manual - Page 96

outdoor1 outdoor2 outdoor3 G R U P A d.o.o. 96 outdoor1 outdoor2 outdoor3 Oil trap (upright projecting pipe, 200mm high), as the figure: outdoor2 outdoor3 outdoor1 Below is forbidden (compressor oil will flow into the lowest outdoor).
Design Manual - Page 102

... controller and the master indoor (directly connected to the "wired control master unit/wired control slave unit/remote control unit table".A, B, C on signal terminal block need not wires and not connect the wired controller. The outdoor and all indoor units are in parallel through 3 polar wires. Either of wired controllers can...
Design Manual - Page 105

Communication wire specs The wire between connecting board to the central controller is the dual-core STP (shielded twisted pair). The detailed specs are as below: wire length(m) Specs
Design Manual - Page 108

...output(KW) FLA: Full load amps(A) Notes: 1. Outdoor unit: units model phase AV08NMVERA 3 AV10NMVERA 3 AV12NMVERA 3 AV14NMVERA 3 AV16NMVERA 3 AV18NMVERA 3 AV20NMVERA 3 AV22NMVERA 3 AV24NMVERA 3 AV26NMVERA 3 AV28NMVERA 3 AV30NMVERA 3 AV32NMVERA 3 AV34NMVERA 3 AV36NMVERA 3 AV38NMVERA 3 ...50 50 55 60 60 70 70 70 85 85 95 95 95 105 105 105 compressor RLA 15 17 19 21 23 15+17 17+17 17+19 17+21 17+23...
Design Manual - Page 110

... set of communication wire, one internet server, one set ,that is required with high precision. General information This management system suits for MRV II series air conditioner. 1.1 Gateway(Model:iGU01) Function:Communication BUS for indoor &Outdoor ,adopt the running status parameters,transmit the control signal .And convert the comminucaition protocal from Homebus...
Design Manual - Page 116

... 1.1 Applicable for MRV II (R22 & R410A) system. 1.2 System combination 1. Inverter protocol adapter (IGU02): Transform the air conditioner protocol into protocol 485; One Microsoft can not work normally. 2. RS 485&232 Converter (hardware), Item 2 & 3... system H-CACS transfer the data of air conditioner to the computer. 2. receive the alarm and make some measures on real time at ...

Similar Questions

Air Conditioner Wont Turn On. It Worked Just Fine Two Days Ago
I have a Haeir air conditioner HPAC9M two days ago it worked fine but now it wont turn on
(Posted by alexisiam 3 years ago)
Portable Air Conditioner Keeps Shutting Off
my portable air conditioner keeps shutting down after running for about 10 min
(Posted by Buttercup2 6 years ago)
Haier Esa412r Air Conditioner Bd Noise Rating
what is the db noise rating for the haier esa412r window air conditioner ar various fan speeds
(Posted by Wfrooney 7 years ago)
Ask a New Question
Use the box below to post a new question about this Haier product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Haier Manuals

Find free Haier AV16NMVERA manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Haier Reviews

View thousands of Haier user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Haier customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Haier customer service rankings, employee comments and much more from our sister site.

Haier Recalls

Find comprehensive Haier recall information updated hourly on RecallOwl.com.