GE GG40T06PVK Support Question
Find answers below for this question about GE GG40T06PVK.Need a GE GG40T06PVK manual? We have 2 online manuals for this item!
Question posted by jnasa on July 31st, 2014
Ge Power Vent Water Heater What Do The Lights Mean
The person who posted this question about this GE product did not include a detailed explanation. Please use the "Request More Information" button to the right if more details would help you to answer this question.
Current Answers
There are currently no answers that have been posted for this question.
Be the first to post an answer! Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.
Be the first to post an answer! Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.
Related GE GG40T06PVK Manual Pages
Use and Care Manual - Page 1
...professional advice. With Installation Instructions for the owner-operator, to install, operate or adjust this water heater read carefully and keep in an explosion or fire.
- This manual also includes a ... of the water heater. ! WHAT TO DO IF YOU SMELL GAS ● Do not try to perform these instructions or any electrical switch; do so may understand how to light any appliance....
Use and Care Manual - Page 2
...Safety Information!
You'll find many helpful hints on your water heater.
These words mean:
! DANGER ! CAUTION Notice:
An imminently hazardous situation ... Potable/Space Heating . . . . . 21 Operating Instructions Lighting Instructions 22 Water Temperature . . . . . 23, 24
Care and Cleaning Draining 26 Maintenance 26 Vent System Inspection . . . . 27 Burner Inspection 27 Extended...
Use and Care Manual - Page 3
...to install the blower assembly and properly vent the water heater to do so can result in the vicinity of this water heater. To avoid the risk of the water heater.
DO NOT handle, use of gasoline
...proper operation. WARNING! Gasoline, as well as other labels on the water heater, as well as outlined in the Venting Section of the Installation Instructions in this manual. Be sure to follow...
Use and Care Manual - Page 5
... smell or recognize this odorant. Bubbling at nose level.
● Before attempting to light the water heater, make sure
your building. ● Leave the house immediately and make sure to ...that must be safe.
5
Troubleshooting Tips
Customer Service Care and Cleaning
● Water heaters utilizing LP gas are recommended in LP & natural gas applications and their installation should...
Use and Care Manual - Page 7
... Z223.1 or National Fire Protection Association, 1 Batterymarch Park, Quincy, MA 02269 as practical to the gas vent or chimney.
● Long hot water lines should be insulated to freezing temperatures.
● Do not install the water heater in bathrooms, bedrooms, any of the combustion air inlet openings located around the lower perimeter of the...
Use and Care Manual - Page 9
... it expands in volume and creates an increase in the cold water inlet line can quickly reach the safety setting of a pressure reducing valve, water meter or water softener. Typical Installation
Vent connector to chimney
Union
Heat trap 6" minimum
Hot water outlet
to fixtures
HOT
Water Heater Jacket
COLD
Temperature and pressure relief valve
Manual gas shut...
Use and Care Manual - Page 10
... Relief Valves and Automatic Gas Shut-Off Devices for the purpose on the tank when it is closed, then open drain to vent from the hot water faucet(s) indicates a full water heater. Drops of any type should be found at www.rheem.com, under "Library", scroll down to allow complete drainage (by gravity) of...
Use and Care Manual - Page 12
... and terminal locations as detailed above have been met. If the water heater is not certified for an existing power vented water heater, a thorough inspection of noise and vibration.
Carefully inspect the entire venting system for proper operation as outlined in this water heater to the left). Check the system for signs of sagging or other structural members to...
Use and Care Manual - Page 13
...of horizontal pipe. For your convenience screens for 3" Vents**
Number of 90° elbows with Vent One (1) One (1) Two (2) Two (2)
Three...vent with a two-inch Schedule 40 PVC 45° vent terminal.
If 3" pipe is supplied with 3" pipe, a Schedule 40 DWV PVC 45° vent terminal must be used , a 2" to 3" bell coupling is approximately equal to 5 feet of pipe.
This water heater...
Use and Care Manual - Page 14
...Painted surfaces will condense as for Testing and Materials (ANSI/ASTM) standards. Insulate vent pipe exposed to cold conditions (attics, crawl spaces, etc.) with inflammable material...surfaces should be a forced air inlet. Operating Instructions Installation Instructions Safety Instructions
Installing the water heater.
Caulk all cracks, seams and joints within ten (10) feet. Eighteen (18...
Use and Care Manual - Page 15
... section for Testing and Materials (ANSI/ASTM) standards.
Complete the vent pipe installation to accommodate the vent pipe.
Refer to the above roof. Mortar or Silicone Caulk Vent Pipe From Water Heater
Pipe Coupling
Horizontal Vent Installation
2' x 2' Sheet Metal Shieldon Brick or Masonry Walls
Once the vent terminal location has been determined, make -up air inlet such...
Use and Care Manual - Page 16
... fitting socket and pipe joint area of cement evenly in a horizontal vent section as close as practical to the water heater vent connection. Apply a thin coat of all dirt, grease or moisture.
NOTICE: Stir the solvent cement frequently while using. Do not apply power until it bottoms out. Condensate is recommended in the socket.
Cut...
Use and Care Manual - Page 17
...all wires prior to pictorial below for water heater internal wiring. Wiring errors can cause ...local codes, in the heater control enclosure.
NOTE: It is provided to permit use an extension cord).
The water heater must be connected to the...Instructions
Wiring
If local codes permit, the water heater may be connected to electric service with the power cord provided (DO NOT use of conduit ...
Use and Care Manual - Page 19
... within the range specified on the rating plate.
❑ DO provide adequate air for joint cement
vapors to dissipate BEFORE applying power to the water heater.
❑ DO ensure that the venting system
complies with the Blower Assembly Dilution Air Holes. Typical horizontal piping arrangement
Please install the insulation, according to the illustrations above...
Use and Care Manual - Page 20
... surfaces
observed and water heater not installed on carpeted floor.
❑ Sufficient fresh air supply for possible gas leak.
❑ Gas Company inspected installation (if
required). D. Venting
❑ Flue baffle properly hung in top of heater's
flue.
❑ Blower assembly properly installed.
❑ Vent connector(s) pitched upward to applying electrical power.
20
Customer Service...
Use and Care Manual - Page 23
..." position and turn the main manual gas valve to the "ON" position, plug the power cord in the vicinity should open and the main burner ignite.
If no pilot light to the "OFF" position.
! TO SHUT OFF WATER HEATER -
Be sure to read and follow the warnings outlined in this manual and on the...
Use and Care Manual - Page 27
... an anode rod designed to prolong the life of the glass lined tank.
NOTICE: Do not remove the anode rod from the water heater's tank, except for an extended period of time, the power and water to the appliance should be drained if they might be checked by qualified service personnel. Make certain the...
Use and Care Manual - Page 28
... jacket.
See the Combustion and Ventilation Air information in gas line.
Gas Cock Knob not correctly positioned. See the "Lighting The Water Heater" section of gas piping, gas control (thermostat), burners, vent connectors or other safety devices. The combustion shutoff device should be inspected by a qualified service technician. Care and Cleaning
Troubleshooting Tips
Customer...
Use and Care Manual - Page 29
... instructions in the "Lighting The Water Heater" section of this manual. See the "Water Temperature Setting" of The Water Heater section of this manual. Make sure all wires prior to a closed . Wiring errors can cause improper and dangerous operation. Water usage may have exceeded the capacity of gas piping, gas control (thermostat), burners, vent connectors or other safety...
Use and Care Manual - Page 30
...water heater is too high, the valve will not operate.
ECO Failure. Vacation Mode Active
Lockout condition. CAUTION: Make certain power to Close. CAUTION: For your safety DO NOT attempt repair of gas piping, remote control, burners, vent...SERVICING.
False Flame (Unwanted Flame Present). System Error, Cycle Power.
● Contact local qualified service technician.
● Contact...
Similar Questions
Ge Power Vent Water Heater
My water heater fires up and ignites but only runs for a few minutes then the flame goes out.It trie...
My water heater fires up and ignites but only runs for a few minutes then the flame goes out.It trie...
(Posted by miller19602003 9 years ago)
My Ge Power Vent Water Heater Is On Lockout How Do I Un Lock It?
(Posted by backtonyt 9 years ago)
Gg50t06pvk Ge Power Vent Water Heater
The ignitor on my unit turns on and gets hot but burner does not fire. Error code shows green light ...
The ignitor on my unit turns on and gets hot but burner does not fire. Error code shows green light ...
(Posted by mjobrien911 12 years ago)