GE GG40T06PVK Support Question
Find answers below for this question about GE GG40T06PVK.Need a GE GG40T06PVK manual? We have 2 online manuals for this item!
Question posted by chaddietrick75 on June 30th, 2013
Ge Gg40t06pvk Combustion Shut-off Device Tripped
How do I reset the the switch, so the buner will stay light
Current Answers
There are currently no answers that have been posted for this question.
Be the first to post an answer! Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.
Be the first to post an answer! Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.
Related GE GG40T06PVK Manual Pages
Use and Care Manual - Page 1
... the State of this water heater should be performed by the gas supplier or fire department.
- Please read the instructions carefully so they may result causing property damage, personal injury or death.
! California Proposition 65 Warning: This product contains chemicals known to cause cancer, birth defects or other combustible materials in manufactured (mobile...
Use and Care Manual - Page 2
...Proof of Troubleshooting Tips first, you will find many helpful hints on your water heater properly.
If you review our chart of the original purchase date is ... 21 Operating Instructions Lighting Instructions 22 Water Temperature . . . . . 23, 24
Care and Cleaning Draining 26 Maintenance 26 Vent System Inspection . . . . 27 Burner Inspection 27 Extended Shut-Down 28
Troubleshooting Tips...
Use and Care Manual - Page 3
.... WARNING!
Be sure to the Care and Cleaning section of a water heater or any other appliance. DANGER! Refer to read and understand the entire Use and Care Manual before attempting to follow the warning label pictured below and other flammable or combustible materials anywhere near or in this manual for proper operation.
Should...
Use and Care Manual - Page 4
... burns or death from scalds. Maximum water temperatures occur just after the burner has shut off.
Water temperatures above may require a 120°F or lower gas control (thermostat) setting to read the thermometer. (See page 23 and 24 for more details.)
The temperature of the water in the heater can be regulated by setting the...
Use and Care Manual - Page 6
.... READ AND FOLLOW THIS SAFETY INFORMATION CAREFULLY.
However, applicable local codes shall govern installation. Turn off the manual shut-off valve if the water heater has been subjected to overheating, fire, flood, physical damage or if the gas supply fails to earthquake motions.
WARNING! FOR INSTALLATIONS IN THE STATE OF ...
Use and Care Manual - Page 7
... a shut down condition of 24" clearance from either the American Gas Association, 400 N. When such areas cannot be avoided it is required between these instructions, local codes, utility company requirements, and/or in an area where leakage from combustible construction:
Front Sides Rear
Top
3"
1"
0"
12"
(7.6 cm) (2.5 cm) (0 cm) (30.5 cm)
! The water heater must...
Use and Care Manual - Page 8
... of any gas burning appliance.
Check the markings on the rating plate of the water heater to the water heater requirements. NOTICE: If the water heater is normally adequate for proper combustion and ventilation.
Care and Cleaning
Troubleshooting Tips
Customer Service
NOTICE: The water heater should not be installed near an air supply containing halogenated hydrocarbons.
8
Corrosive...
Use and Care Manual - Page 9
... in the cold water line between the water heater and the check valve (see illustration below for complete instructions. Install a shut-off valve: See (NFGC) for suggested method of "thermal expansion" can cause premature failure of unions or flexible copper connectors is designed with an air cushion built in the inlet water line. Combustion Air Inlet...
Use and Care Manual - Page 10
... tank must remain in the opening provided and marked for hot water distribution. The water heater warranty does not cover damage or failure resulting from operation with the Standard for Relief Valves and Automatic Gas Shut-Off Devices for possible leaks. Open each hot water faucet slowly to vent from the valve to allow the air...
Use and Care Manual - Page 11
... damage, personal injury, or death could result in hazardous operating conditions.
Leak Testing
The water heater and its manual gas shut-off valve during any pressure testing of 3/8 psi (10.5" w.c.) for natural gas, or...fittings. The National Fuel Gas Code (NFGC) mandates a manual gas shut-off valve near the water heater. Use compound sparingly on the rating plate. for LP gas.
At ...
Use and Care Manual - Page 18
... top of such unauthorized devices. This will interfere with the kit must be carefully followed. This area must be unobstructed so as not to restrict the proper function and operation of the water heater:
● Do not cover the operating or warning labels attached to the water heater or attempt to the combustion air inlet openings...
Use and Care Manual - Page 19
...combustion
and ventilation as specified on any burner access door that has been removed.
❑ DON'T install this water heater...water heater.
❑ DO ensure that the venting system
complies with factory installed 3/4" NPT heat traps in the Use and Care Manual and National Fuel Gas Code.
❑ DO contact a qualified service technician
if the pilot or main burner will not stay...
Use and Care Manual - Page 20
...least 6" from
combustible material.
❑ Vapors from combustible surfaces
observed and water heater not installed on carpeted floor.
❑ Sufficient fresh air supply for proper
operation of water heater.
❑... clear of the base of the heater.
❑ Clearances of length minimum) .
❑ Vent connector(s) securely fastened together
with shut-off valve, union
and sediment trap...
Use and Care Manual - Page 21
... to house
From HOT outlet on
water heater
Hot water supply to water heater
Temperature and pressure relief valve
Water heater jacket
Cold water return line from heating unit (not supplied with water heater)
Gas line to heating unit
Tee fitting for boiler treatment, into heating unit
Drain valve (not supplied with water heater)
Shut-off valve
Isolation valve in some heating units...
Use and Care Manual - Page 23
... outer door. A warning light will alert the user of injury, it is established, the gas control will be used as the water begins to the "ON" position, plug the power cord in the "ON" position. TO SHUT OFF WATER HEATER - Care and Cleaning
CAUTION: Hydrogen gas can be shut off . Do Not allow combustible materials such as...
Use and Care Manual - Page 24
...
Operating the water heater.
Each reference mark above or below these points indicates an approximate change of the gas control system which has been under water.
Stacking can occur when a series of 120°F. NOTICE: Replace any reason. To determine the water temperature, turn off the manual gas control (shut-off device that hotter water increases the...
Use and Care Manual - Page 25
...: Shut off the cold water supply.
It is no one will be used to see that it is free of dependable trouble-free service. Strategically located risers in the water pipe system or water hammer arresting devices can cover the gas control (thermostat) sensors, causing the sensors to the danger of the water heater down if undesirable combustion...
Use and Care Manual - Page 26
... of burner operation.
To ensure sufficient ventilation and combustion air supply, proper clearances must be shut off and inspect the main burner while firing.
Make certain the vent connector from the water heater. DO NOT obstruct or block the Flammable Vapor Sensor.
Venting System Inspection
The water heater's internal flue must not be inspected annually to...
Use and Care Manual - Page 28
.... Pilot burner does not stay Gas Controls (Thermostat's)
lit
single use gas shut-off device that meets the requirements of your safety DO NOT attempt repair of combustion condensing on water heater jacket. This is normal and will cause condensation. Combustion Shutoff Device Tripped.
This water heater incorporates a combustion shut off device
has opened.
Operating Instructions...
Use and Care Manual - Page 29
... may have exceeded the capacity of this . Blower unplugged.
stay lit. Wait for the water heater to a closed . If necessary, relight using the instructions in the "Lighting The Water Heater" section of this manual. CAUTION: Label all faucets are closed system. Combustion Shutoff System tripped
The gas control (thermostat) is too hot
The gas control (thermostat) may be...
Similar Questions
What Is The Part Number For The Anode Rod For The Ge Water Heater: Model # Pe50
What is the part number for the anode rod for the GE water heater: Model # PE50M09AAH - SERIAL # GE1...
What is the part number for the anode rod for the GE water heater: Model # PE50M09AAH - SERIAL # GE1...
(Posted by dries13644 4 years ago)
Ge Power Vent Water Heater
My water heater fires up and ignites but only runs for a few minutes then the flame goes out.It trie...
My water heater fires up and ignites but only runs for a few minutes then the flame goes out.It trie...
(Posted by miller19602003 9 years ago)
How Reset Ge Ge Gg40t06pvk Water Heater Vaper Censor Code
(Posted by FixMcamer 9 years ago)
How Reset Ge Ge Gg40t06pvk Water Heater Vapor Sensor Code
(Posted by drin2winmar 9 years ago)
Breaker Keeps Tripping Water Heater Ge50t06aag
Just recently my hot water heater keeps tripping the breaker. I can flip it on have hot water for ab...
Just recently my hot water heater keeps tripping the breaker. I can flip it on have hot water for ab...
(Posted by johnladebauche 13 years ago)