GE GE30S06AAG Support Question
Find answers below for this question about GE GE30S06AAG.Need a GE GE30S06AAG manual? We have 2 online manuals for this item!
Question posted by CJP9562 on January 29th, 2012
I Am Getting Rotten Egg Smell Of Hot Water. Where Is The Anode Rod
IS THER A CERTAIN ONE I SHOULD REPLACE WITH. HEATER IS 1 YEAR OLD
Current Answers
Answer #1: Posted by Anonymous-161698 on January 28th, 2017 3:48 PM
if you have some sort of water purification system it's because you've got no chlorine in your water and a magnesium anode rod providing food for bacteria at a perfect incubation temp, short term fix= crank it to 135, long term replace magnesium anode rod with aluminum. Alternately you could add a chlorine injector, or a peroxide injector post system, prior to heater
Related GE GE30S06AAG Manual Pages
Similar Questions
Change Elements
30 gallon with model number GE30s06AAG. What is the element to get to replace.
30 gallon with model number GE30s06AAG. What is the element to get to replace.
(Posted by jamamaw55 2 years ago)
I Have A Hot Water Heater And I See Water In The Protective Pan.
I believe that it needs parts installed. It is 5 years old and some items are covered by the 6 year ...
I believe that it needs parts installed. It is 5 years old and some items are covered by the 6 year ...
(Posted by nancb961 6 years ago)
Hot Water Heater Issue
I have a hot water heater that won't keep the water hot Model It was installed by a plumber in Sept...
I have a hot water heater that won't keep the water hot Model It was installed by a plumber in Sept...
(Posted by debbieburry 8 years ago)
Hot Water Heater Won't Heat The Water
4 weeks ago I found the lower heating element to be corroded. I replaced the element and confirmed t...
4 weeks ago I found the lower heating element to be corroded. I replaced the element and confirmed t...
(Posted by djkoban 10 years ago)
Problem With Water Heater Ge30s06aag.
the siemens double circuit breaker of 30 amps is tripping from time to time. I just replaced the bre...
the siemens double circuit breaker of 30 amps is tripping from time to time. I just replaced the bre...
(Posted by pboisson 11 years ago)