Frigidaire FRA073PU1 Support Question
Find answers below for this question about Frigidaire FRA073PU1.Need a Frigidaire FRA073PU1 manual? We have 4 online manuals for this item!
Question posted by yzhao23 on June 20th, 2011
Drainage Problem, Water Come Out From Both Holes When It Is In Cooling Mode.
Water comes out from both dehumidify hole and the bottom hole when it is in cooling mode.
Should I connect two hosesA311;
Current Answers
Answer #1: Posted by OnlineOutreachSpecialist on June 22nd, 2011 8:45 AM
The dehumidifiers are designed so that they drain from the drip tray to the bucket occurs from the continuous drain connection. As long as a hose is not connected, it should drain directly to the bucket. When you connect a hose, the bucket is by-passed. Sometimes leaks can occur in the hose connection and/or washer that will dip into the bucket shutting down the unit. The hole in the drip tray is an overflow port that is supposed to come into play only if the continuous drain hose gets plugged. The hole has a lip that causes the water to normally be directed to the continuous drain, but allow it to drain to the bucket if the hose is blocked. This all depends on the unit being placed on a flat level floor.
Check that the rubber washer for the female threaded end of the drain hose had not somehow gotten deformed and blocked the hole that water normally would discharge from into the hose when continuous running was desired. Also you may tilt the unit slightly toward the back - something like a window air conditioner may need to be slightly tilted in order to get the condensate to flow to the drain hole. We have also found that the type of hoses used can have an effect as well. The larger the hose the better the water will flow, some of the smaller hoses can cause a dam effect, meaning that the water can not make it over the lip and will go into the bucket as a result.
Please let us know if you need any further information or assistance.
Check that the rubber washer for the female threaded end of the drain hose had not somehow gotten deformed and blocked the hole that water normally would discharge from into the hose when continuous running was desired. Also you may tilt the unit slightly toward the back - something like a window air conditioner may need to be slightly tilted in order to get the condensate to flow to the drain hole. We have also found that the type of hoses used can have an effect as well. The larger the hose the better the water will flow, some of the smaller hoses can cause a dam effect, meaning that the water can not make it over the lip and will go into the bucket as a result.
Please let us know if you need any further information or assistance.
Online Outreach Specialist
Related Frigidaire FRA073PU1 Manual Pages
Similar Questions
Fra073pu1 Keeps Beeping, Sounds Once About Every 1 Min.
(Posted by yzhao232845 2 years ago)
Dehumidifier Model Fdl7051 Trips A 20 Amp Circuit Breaker After Running 5 To 10
My dehumidifier trips the 20 amp circuit breaker after running 5 to 10 minutes. I replaced the circu...
My dehumidifier trips the 20 amp circuit breaker after running 5 to 10 minutes. I replaced the circu...
(Posted by lmpage59 5 years ago)
Why Does Water Go In Bucket When Hose Is Connected To Dehumidifier
(Posted by tiff2hawkn 9 years ago)
Continuous Drainage Problems?
I have the hose hooked up and the unit is set to CO setting but the bucket still fills up.Does this ...
I have the hose hooked up and the unit is set to CO setting but the bucket still fills up.Does this ...
(Posted by Anonymous-39382 12 years ago)
Water Leak
How do I get the water out of the pan which is located so low to the floor. I had 3 gallons of water...
How do I get the water out of the pan which is located so low to the floor. I had 3 gallons of water...
(Posted by richardbiglin62 12 years ago)