On Board Regulator Failed - Call Support
Current Answers
Answer #1: Posted by DellChrisH on September 12th, 2012 9:15 AM
- System board
- CPU1 (Min for troubleshooting)
- Heatsink for CPU1 for prevention of over-heating
- One memory DIMM in DIMM A1 for CPU1.
- Power Supply (PDB is required for redundant PSU)
- Control Panel
After removing devices restart, access the Drac/ESM (CTRL-E) and clear HW Log, then boot and see if the system gets past the error.
If it doesn't and error remains then you will need to look at replacing the motherboard for the system