Dimension Guide
Page 1
...cabinet depth B. 30" (76.2 cm) min. from either cabinet, 5¹⁄₂" (14.0 cm) max. Because Whirlpool Corporation policy includes ...range can be raised approximately 1" (2.5 cm) by not less than 1/4" (6.4 mm) flame retardant millboard covered with not less than No. 28 MSG sheet steel, 0.015" (0.4 mm) stainless steel, 0.024" (0.6 mm) aluminum or 0.020" (0.5 mm) copper. 30" (76.2 cm) min. opening width C. required...C E D A. 27 69.9 cm) max. 30" (76 cm) Freestanding Electric Range PRODUCT MODEL NUMBERS GFE461LV GFE471LV WFE301LV WFE361LV WFE364LV WFE366LV WFE371LV WFE374LV ...
...cabinet depth B. 30" (76.2 cm) min. from either cabinet, 5¹⁄₂" (14.0 cm) max. Because Whirlpool Corporation policy includes ...range can be raised approximately 1" (2.5 cm) by not less than 1/4" (6.4 mm) flame retardant millboard covered with not less than No. 28 MSG sheet steel, 0.015" (0.4 mm) stainless steel, 0.024" (0.6 mm) aluminum or 0.020" (0.5 mm) copper. 30" (76.2 cm) min. opening width C. required...C E D A. 27 69.9 cm) max. 30" (76 cm) Freestanding Electric Range PRODUCT MODEL NUMBERS GFE461LV GFE471LV WFE301LV WFE361LV WFE364LV WFE366LV WFE371LV WFE374LV ...
Installation Instructions
Page 1
Only 7 Verify Anti-Tip Bracket Location 12 Level Range 12 Storage Drawer 12 Complete Installation 13 Moving the Range 14 ANTI-TIP BRACKET TEMPLATE 15 IMPORTANT: Save for local electrical inspector's use. U.S.A. Only 4 INSTALLATION INSTRUCTIONS 6 Unpack Range 6 Install Anti-Tip Bracket 6 Electrical Connection - W10252706B INSTALLATION INSTRUCTIONS 30" (76 CM) FREESTANDING ELECTRIC RANGES Table of Contents RANGE SAFETY 2 INSTALLATION REQUIREMENTS 3 Tools and Parts 3 Location Requirements 3 Electrical Requirements - U.S.A.
Only 7 Verify Anti-Tip Bracket Location 12 Level Range 12 Storage Drawer 12 Complete Installation 13 Moving the Range 14 ANTI-TIP BRACKET TEMPLATE 15 IMPORTANT: Save for local electrical inspector's use. U.S.A. Only 4 INSTALLATION INSTRUCTIONS 6 Unpack Range 6 Install Anti-Tip Bracket 6 Electrical Connection - W10252706B INSTALLATION INSTRUCTIONS 30" (76 CM) FREESTANDING ELECTRIC RANGES Table of Contents RANGE SAFETY 2 INSTALLATION REQUIREMENTS 3 Tools and Parts 3 Location Requirements 3 Electrical Requirements - U.S.A.
Installation Instructions
Page 3
.... The model/serial rating plate is the installer's responsibility to subfloor. See "Electrical Requirements" section. IMPORTANT: To avoid damage to your cabinets, check with installation clearances specified on the left side frame behind the storage drawer panel. ■ The range should be located for Manufactured Home Installations, ANSI A225.1/NFPA 501A or local...
.... The model/serial rating plate is the installer's responsibility to subfloor. See "Electrical Requirements" section. IMPORTANT: To avoid damage to your cabinets, check with installation clearances specified on the left side frame behind the storage drawer panel. ■ The range should be located for Manufactured Home Installations, ANSI A225.1/NFPA 501A or local...
Installation Instructions
Page 4
...less than ¹⁄₄" (0.64 cm) flame retardant millboard covered with local codes. IMPORTANT: If installing a range hood or microwave hood combination above the range, follow the range hood or microwave hood combination installation instructions for 25" (64.0 cm) countertop depth, 24" (61.0 cm)...0.024" (0.6 mm) aluminum or 0.020" (0.5 mm) copper. 30" (76.2 cm) minimum clearance between cutout and cabinet door or hinge. *NOTE: 24" (61.0 cm) minimum when bottom of electric shock. A. 13" (33.0 cm) max. required between the top of the cooking platform and the bottom of the ...
...less than ¹⁄₄" (0.64 cm) flame retardant millboard covered with local codes. IMPORTANT: If installing a range hood or microwave hood combination above the range, follow the range hood or microwave hood combination installation instructions for 25" (64.0 cm) countertop depth, 24" (61.0 cm)...0.024" (0.6 mm) aluminum or 0.020" (0.5 mm) copper. 30" (76.2 cm) minimum clearance between cutout and cabinet door or hinge. *NOTE: 24" (61.0 cm) minimum when bottom of electric shock. A. 13" (33.0 cm) max. required between the top of the cooking platform and the bottom of the ...
Installation Instructions
Page 5
...terminals with upturned ends, terminating in the "Product Dimensions" section of the "Location Requirements" section. ■ This range is used . or 50-amp range power supply cord (pigtail). Refer to the proper electrical voltage and frequency as specified on the supply end. Cord should be Type SRD... 1 No.-10 white neutral 1 No.-8 green grounding If connecting to the cabinet. See "Electrical Connection." When a 4-wire receptacle of NEMA Type 14-50R is manufactured with the rating of the range. ■ The wiring diagram is located on the back of NEMA Type 10-50R. 3-...
...terminals with upturned ends, terminating in the "Product Dimensions" section of the "Location Requirements" section. ■ This range is used . or 50-amp range power supply cord (pigtail). Refer to the proper electrical voltage and frequency as specified on the supply end. Cord should be Type SRD... 1 No.-10 white neutral 1 No.-8 green grounding If connecting to the cabinet. See "Electrical Connection." When a 4-wire receptacle of NEMA Type 14-50R is manufactured with the rating of the range. ■ The wiring diagram is located on the back of NEMA Type 10-50R. 3-...
Installation Instructions
Page 10
... according to your electrical supply, make the required 3-wire or 4-wire connection. 1. Terminal block B. Bare (green) ground wire E. Ground-link screw 2. Line 1 (black) wire Bare Wire Torque Specifications Attaching terminal lugs to the ... 6 gauge aluminum 25 lbs-in. (2.8 N-m) 35 lbs-in the wire to remove the ground-link screw from the end of the range. Allow enough slack to easily attach wiring to the range with the ground-link screw and ground-link section. Cord/conduit plate D. Neutral (white) wire G. Save the ground-link screw...
... according to your electrical supply, make the required 3-wire or 4-wire connection. 1. Terminal block B. Bare (green) ground wire E. Ground-link screw 2. Line 1 (black) wire Bare Wire Torque Specifications Attaching terminal lugs to the ... 6 gauge aluminum 25 lbs-in. (2.8 N-m) 35 lbs-in the wire to remove the ground-link screw from the end of the range. Allow enough slack to easily attach wiring to the range with the ground-link screw and ground-link section. Cord/conduit plate D. Neutral (white) wire G. Save the ground-link screw...
Owners Manual
Page 12
.... Service calls to refrigerator or freezer product failures. 7. Repairs when your major appliance for Factory Specified Parts and repair labor to Whirlpool within 30 days from the date of purchase. 6. Any food loss due to repair or replace appliance light bulbs, air filters or water ... with the product, Whirlpool Corporation or Whirlpool Canada LP (hereafter "Whirlpool") will pay for repairs. Major appliances with electrical or plumbing codes, or use or when it is used in the country in which it is installed in an inaccessible location or is required to obtain service under...
.... Service calls to refrigerator or freezer product failures. 7. Repairs when your major appliance for Factory Specified Parts and repair labor to Whirlpool within 30 days from the date of purchase. 6. Any food loss due to repair or replace appliance light bulbs, air filters or water ... with the product, Whirlpool Corporation or Whirlpool Canada LP (hereafter "Whirlpool") will pay for repairs. Major appliances with electrical or plumbing codes, or use or when it is used in the country in which it is installed in an inaccessible location or is required to obtain service under...
Warranty
Page 1
... appliance is located in -home service is covered by a Whirlpool designated service company. You can write to Whirlpool with electrical or plumbing codes, or use of consumables or cleaning products ... in materials or workmanship. Proof of your product or you would like to Whirlpool within 30 days from warranty coverage. 3. Costs associated with original model/serial numbers that ... determined. If outside the 50 United States and Canada, contact your major appliance is required to correct house wiring or plumbing. 2. IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY OR...
... appliance is located in -home service is covered by a Whirlpool designated service company. You can write to Whirlpool with electrical or plumbing codes, or use of consumables or cleaning products ... in materials or workmanship. Proof of your product or you would like to Whirlpool within 30 days from warranty coverage. 3. Costs associated with original model/serial numbers that ... determined. If outside the 50 United States and Canada, contact your major appliance is required to correct house wiring or plumbing. 2. IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY OR...