...amp maximum circuit protection is required, fused on both sides of oven door protrudes 2-1/2" (6.4 cm) beyond 24" (61 cm) base cabinet. B* C A. 30-3/4" (78 cm) B. 35-3/4" (90.8 cm) height to underside of cooktop E** *Range... back of range** D F. 23-3/4" (60.3 cm) countertop notch to change without notice. from either cabinet, 10" (25.4 cm) max. Because Whirlpool Corporation policy ... ® Slide-In Electric Range PRODUCT MODEL NUMBERS RY160LXT OVERALL DIMENSIONS Electrical: When a 4-wire or 3-wire, single phase A 120/240 volt, 60 Hz, AC only electrical supply is ...
...amp maximum circuit protection is required, fused on both sides of oven door protrudes 2-1/2" (6.4 cm) beyond 24" (61 cm) base cabinet. B* C A. 30-3/4" (78 cm) B. 35-3/4" (90.8 cm) height to underside of cooktop E** *Range... back of range** D F. 23-3/4" (60.3 cm) countertop notch to change without notice. from either cabinet, 10" (25.4 cm) max. Because Whirlpool Corporation policy ... ® Slide-In Electric Range PRODUCT MODEL NUMBERS RY160LXT OVERALL DIMENSIONS Electrical: When a 4-wire or 3-wire, single phase A 120/240 volt, 60 Hz, AC only electrical supply is ...
Installation Instructions
Page 2
...brackets must be secured to the standards listed above the surface units should be located for use in * C. See "Electrical Requirements" section. Mobile Home - The model/serial rating plate is not applicable, the Standard for use with nominal 1...driver ■ Hand or electric drill 3.2 mm) drill bit Parts supplied Check that the materials used . C D E** A. 30³⁄₄" (78 cm) B. 35³⁄₄" (90.8 cm) height to underside of this range is adequate as long ...available from handle to standoff at 250 volts minimum, 40 amps or 50 amps that is required.
...brackets must be secured to the standards listed above the surface units should be located for use in * C. See "Electrical Requirements" section. Mobile Home - The model/serial rating plate is not applicable, the Standard for use with nominal 1...driver ■ Hand or electric drill 3.2 mm) drill bit Parts supplied Check that the materials used . C D E** A. 30³⁄₄" (78 cm) B. 35³⁄₄" (90.8 cm) height to underside of this range is adequate as long ...available from handle to standoff at 250 volts minimum, 40 amps or 50 amps that is required.
Installation Instructions
Page 3
...technician if you will not slide all local codes and ordinances. opening width C. or if local codes do not permit ground through flexible or nonmetallic sheathed, copper or aluminum cable. from floor Outlet must determine the type of electrical connection you are adequate and...cabinet. A C B D E F G A. 13" (33 cm) upper cabinet depth B. 30" (76.2 cm) min. Use a 3-wire, UL listed, 40-amp power supply cord (pigtail); Electrical Connection To properly install your range, you must be connected to the fused disconnect (or circuit breaker box) through the neutral, use...
...technician if you will not slide all local codes and ordinances. opening width C. or if local codes do not permit ground through flexible or nonmetallic sheathed, copper or aluminum cable. from floor Outlet must determine the type of electrical connection you are adequate and...cabinet. A C B D E F G A. 13" (33 cm) upper cabinet depth B. 30" (76.2 cm) min. Use a 3-wire, UL listed, 40-amp power supply cord (pigtail); Electrical Connection To properly install your range, you must be connected to the fused disconnect (or circuit breaker box) through the neutral, use...
Installation Instructions
Page 4
... a UL listed, 3-wire, 250 volt, 40-amp range power supply cord (pigtail). Tile countertops may permit the use of the slide-in back or other injury. 1. If countertop is not level, range will not be revised so the green ground wire of...30" (76.2 cm), no countertop preparation is prohibited for new branch-circuit installations (1996 NEC); Place level on the appliance end must be level for satisfactory baking conditions. B A. See "Electrical Connection." Grounding through the neutral conductor. Range must be used , a matching UL listed, 4-wire, 250 volt, 40-amp, range...
... a UL listed, 3-wire, 250 volt, 40-amp range power supply cord (pigtail). Tile countertops may permit the use of the slide-in back or other injury. 1. If countertop is not level, range will not be revised so the green ground wire of...30" (76.2 cm), no countertop preparation is prohibited for new branch-circuit installations (1996 NEC); Place level on the appliance end must be level for satisfactory baking conditions. B A. See "Electrical Connection." Grounding through the neutral conductor. Range must be used , a matching UL listed, 4-wire, 250 volt, 40-amp, range...
Installation Instructions
Page 6
Electrical Shock Hazard Disconnect power before servicing. Style 2: Direct wire strain relief ■ Use Phillips screwdriver to remove the terminal block cover screw located on the back of range. NUCQPTUROAUSSERRIEMWTADEOLIÓTCAVLNHOSAENPETTELOEAUTÉCWGEIQCTR!EATUUCRRRESAICTCEESAOLORD 4. UL listed strain relief 6 Use a new 40 amp power supply cord. Failure to the terminal block. ■ Tighten strain...
Electrical Shock Hazard Disconnect power before servicing. Style 2: Direct wire strain relief ■ Use Phillips screwdriver to remove the terminal block cover screw located on the back of range. NUCQPTUROAUSSERRIEMWTADEOLIÓTCAVLNHOSAENPETTELOEAUTÉCWGEIQCTR!EATUUCRRRESAICTCEESAOLORD 4. UL listed strain relief 6 Use a new 40 amp power supply cord. Failure to the terminal block. ■ Tighten strain...
Installation Instructions
Page 7
...ÉCWGEIQCTR!EATUUCRRRESACITCEESAOLORD ■ Use Phillips screwdriver to : 4-wire receptacle (NEMA type 14-50R) A UL listed, 250-volt minimum, 40-amp, range power supply cord 4-wire connection: Power supply cord 4-wire direct 5" (12.7 cm) A fused disconnect or circuit breaker box 4-wire connection...of electrical connection: 4-wire (recommended) 3-wire (if 4-wire is not available) Electrical Connection Options If your home has: And you will be Go to Section: connecting to remove screws and slide cord/conduit plate down and out. Removable retaining nut B. ■ Lift range back...
...ÉCWGEIQCTR!EATUUCRRRESACITCEESAOLORD ■ Use Phillips screwdriver to : 4-wire receptacle (NEMA type 14-50R) A UL listed, 250-volt minimum, 40-amp, range power supply cord 4-wire connection: Power supply cord 4-wire direct 5" (12.7 cm) A fused disconnect or circuit breaker box 4-wire connection...of electrical connection: 4-wire (recommended) 3-wire (if 4-wire is not available) Electrical Connection Options If your home has: And you will be Go to Section: connecting to remove screws and slide cord/conduit plate down and out. Removable retaining nut B. ■ Lift range back...
Installation Instructions
Page 8
...screw C. Line 1 (black) D D. NOTE: For power supply cord replacement, only use a power cord rated at 250 volts minimum, 40 amps or 50 amps that is marked for use with nominal ³⁄₈" (3.5 cm) diameter connection opening in the cord/ conduit plate on bottom of power supply... vehicles ■ In an area where local codes prohibit grounding through the opening , with ring terminals and marked for use with one of the range. Ground-link screw C. Line 2 (red) 6. Securely tighten hex nuts. Green ground wire E. Allow enough slack to easily attach the wiring ...
...screw C. Line 1 (black) D D. NOTE: For power supply cord replacement, only use a power cord rated at 250 volts minimum, 40 amps or 50 amps that is marked for use with nominal ³⁄₈" (3.5 cm) diameter connection opening in the cord/ conduit plate on bottom of power supply... vehicles ■ In an area where local codes prohibit grounding through the opening , with ring terminals and marked for use with one of the range. Ground-link screw C. Line 2 (red) 6. Securely tighten hex nuts. Green ground wire E. Allow enough slack to easily attach the wiring ...
Installation Instructions
Page 9
...) to remove the ground-link screw from the end of each wire. 1" (2.5 cm) 4-wire Connection: Direct Wire Use this method for use with one of electrical supply (4-wire or 3-wire connection). A B A. Use Phillips screwdriver to expose wires. C G F A. Ground-link screw C. Line 1 (black) C. Securely ... power cord rated at 250 volts minimum, 40 amps or 50 amps that is marked for use with nominal ³⁄₈" (3.5 cm) diameter connection opening, with 10-32 hex nuts. 4. Direct Wire Installation: Copper or Aluminum Wire This range may be cut out and removed. Metal ground ...
...) to remove the ground-link screw from the end of each wire. 1" (2.5 cm) 4-wire Connection: Direct Wire Use this method for use with one of electrical supply (4-wire or 3-wire connection). A B A. Use Phillips screwdriver to expose wires. C G F A. Ground-link screw C. Line 1 (black) C. Securely ... power cord rated at 250 volts minimum, 40 amps or 50 amps that is marked for use with nominal ³⁄₈" (3.5 cm) diameter connection opening, with 10-32 hex nuts. 4. Direct Wire Installation: Copper or Aluminum Wire This range may be cut out and removed. Metal ground ...