Installation Instructions
Page 15
... down onto the Natural gas orifice spud and remove by turning it . A LP Gas Orifice Spud Chart Burner Rating Color 4,000 BTU Blue 7,000 BTU Black 9,100 BTU Green 14,000 BTU Red Number 64L 81L 97L 114L 5. Replace burner base and hand tighten the screws. 7. Repeat steps 1 through 7 for each...
... down onto the Natural gas orifice spud and remove by turning it . A LP Gas Orifice Spud Chart Burner Rating Color 4,000 BTU Blue 7,000 BTU Black 9,100 BTU Green 14,000 BTU Red Number 64L 81L 97L 114L 5. Replace burner base and hand tighten the screws. 7. Repeat steps 1 through 7 for each...
Installation Instructions
Page 18
... 5,000 BTU Green 107N 7,300 BTU Yellow 125N 9,200 BTU Orange 142N 10,000 BTU Clear 149N 15,000 BTU White 180N 16,000 BTU Black 195N 5. Natural gas flames do not have a very distinct blue flame ¼" to ½" long. Broil burner orifice hood B. LP gas orifice spud Use the...
... 5,000 BTU Green 107N 7,300 BTU Yellow 125N 9,200 BTU Orange 142N 10,000 BTU Clear 149N 15,000 BTU White 180N 16,000 BTU Black 195N 5. Natural gas flames do not have a very distinct blue flame ¼" to ½" long. Broil burner orifice hood B. LP gas orifice spud Use the...