Specs
Page 1
...), Mint Julep (MJ), Sea Glass (SE), Iridescent Blue (IB), Viking Blue (VB), Pumpkin (PM), Racing Red (RR), Apple Red (AR), Burgundy (BU), Plum (PL), Chocolate (CH), and Cobalt Blue (CB). • Finish designates front and sides. • Accessory Rail Option-Front of hood. (Must be ordered factory installed) o Stainless Steel/Chrome (CR...
...), Mint Julep (MJ), Sea Glass (SE), Iridescent Blue (IB), Viking Blue (VB), Pumpkin (PM), Racing Red (RR), Apple Red (AR), Burgundy (BU), Plum (PL), Chocolate (CH), and Cobalt Blue (CB). • Finish designates front and sides. • Accessory Rail Option-Front of hood. (Must be ordered factory installed) o Stainless Steel/Chrome (CR...
Specs
Page 2
...BT), Cotton White (CW), Oyster Gray (OG), Golden Mist (GM), Lemonade (LE), Sage (SA), Mint Julep (MJ), Sea Glass (SE), Iridescent Blue (IB), Viking Blue (VB), Pumpkin (PM), Racing Red (RR), Apple Red (AR), Burgundy (BU), Plum (PL), Chocolate (CH), and Cobalt Blue (CB). • Finish designates...are separate, allowing you to leave dimmer at favorite position • Easy cleanup o Design of low-profile filter system means less interior hood space to be converted to recirculate, but may be cleaned o Canopy interior is completely lined in stainless steel for increased rigidity, seamless ...
...BT), Cotton White (CW), Oyster Gray (OG), Golden Mist (GM), Lemonade (LE), Sage (SA), Mint Julep (MJ), Sea Glass (SE), Iridescent Blue (IB), Viking Blue (VB), Pumpkin (PM), Racing Red (RR), Apple Red (AR), Burgundy (BU), Plum (PL), Chocolate (CH), and Cobalt Blue (CB). • Finish designates...are separate, allowing you to leave dimmer at favorite position • Easy cleanup o Design of low-profile filter system means less interior hood space to be converted to recirculate, but may be cleaned o Canopy interior is completely lined in stainless steel for increased rigidity, seamless ...
Specs
Page 3
...information, including conversion kits, filters, duct covers, backsplashes, and warming shelf panels. Ship. Chimney Wall Hood w/Ventilator/ Dimensions & Specifications PRODUCT DIMENSIONS VWH Professional Wall Hood (301.52"cm) DCH Designer Chimney Wall Hood (301.52"cm) (401.66"cm) (15.62"cm) A PROFESSIONAL (532.31"cm)..." cm) (301.52"cm) (401.66"cm) (5.12"cm) A DESIGNER W/RECIRCULATING KIT (612.04"cm) (301.52"cm) Model VWH2410 VWH3010 VWH3610 DCH3042 DCH3642 Hood Width (A) Height 23-7/8" (60.6 cm) 10" (25.4 cm) 29-7/8" (75.9 cm) 10" (25.4 cm) 35-7/8" (91.1 cm) 10" (25.4 ...
...information, including conversion kits, filters, duct covers, backsplashes, and warming shelf panels. Ship. Chimney Wall Hood w/Ventilator/ Dimensions & Specifications PRODUCT DIMENSIONS VWH Professional Wall Hood (301.52"cm) DCH Designer Chimney Wall Hood (301.52"cm) (401.66"cm) (15.62"cm) A PROFESSIONAL (532.31"cm)..." cm) (301.52"cm) (401.66"cm) (5.12"cm) A DESIGNER W/RECIRCULATING KIT (612.04"cm) (301.52"cm) Model VWH2410 VWH3010 VWH3610 DCH3042 DCH3642 Hood Width (A) Height 23-7/8" (60.6 cm) 10" (25.4 cm) 29-7/8" (75.9 cm) 10" (25.4 cm) 35-7/8" (91.1 cm) 10" (25.4 ...
Specs
Page 4
... conversion kits, filters, duct covers, backsplashes, and warming shelf panels. INFORMATION SUBJECT TO CHANGE Wall Hood w/Ventilator Dimensions & Specifications PRODUCT DIMENSIONS DWH Designer Replacement Wall Hood (5.12"cm) A DESIGNER (502.80"cm) (15.62"cm) Model DWH3006 DWH3606 Hood Width (A) Height 29-7/8" (75.9 cm) 6" (15.24 cm) 35-7/8" (91.1 cm) 6" (15.24 cm...
... conversion kits, filters, duct covers, backsplashes, and warming shelf panels. INFORMATION SUBJECT TO CHANGE Wall Hood w/Ventilator Dimensions & Specifications PRODUCT DIMENSIONS DWH Designer Replacement Wall Hood (5.12"cm) A DESIGNER (502.80"cm) (15.62"cm) Model DWH3006 DWH3606 Hood Width (A) Height 29-7/8" (75.9 cm) 6" (15.24 cm) 35-7/8" (91.1 cm) 6" (15.24 cm...
Specs
Page 5
... DESIGN GUIDE VIKINGRANGE.COM • 1-888-VIKING1 REVISED 5/2/11 © 2 0 1 1 V R C - Wall Hood w/Ventilator (913.46"cm) ((6611356020""t..mmo40 accinmmx..)) 22((766418""..mt06moaccimmxn..))* (913.46"cm) ((6611967675""t..mmo63 accinmmx..)) 33((783063""..t28mmoccaimmnx.)). INFORMATION SUBJECT TO CHANGE Wall Hood w/Ventilator/ 12"H. Chimney Wall Hood w/Ventilator 6"H. Dimensions & Specifications CLEARANCE DIMENSIONS VENTILATION Built-In 10"H. dimensions must...
... DESIGN GUIDE VIKINGRANGE.COM • 1-888-VIKING1 REVISED 5/2/11 © 2 0 1 1 V R C - Wall Hood w/Ventilator (913.46"cm) ((6611356020""t..mmo40 accinmmx..)) 22((766418""..mt06moaccimmxn..))* (913.46"cm) ((6611967675""t..mmo63 accinmmx..)) 33((783063""..t28mmoccaimmnx.)). INFORMATION SUBJECT TO CHANGE Wall Hood w/Ventilator/ 12"H. Chimney Wall Hood w/Ventilator 6"H. Dimensions & Specifications CLEARANCE DIMENSIONS VENTILATION Built-In 10"H. dimensions must...
Specs
Page 6
...8226; VWH/DCH - 7" round duct • DWH - 3-1/4" x 10" round duct or equivalent o Never use flexible duct; Wall Hood w/Ventilator/ 12"H. Without applying static pressure (some brands do not), CFM could be greatly overstated. GAS Not applicable ELECTRICAL • Hardwire..." (25.4 cm) Interior Max. amp usage-5.6 PLUMBING Not applicable Note: All CFMs are best; Installation Requirements VENTILATION Built-In 10"H. Chimney Wall Hood w/Ventilator 6"H. UTILITY REQUIREMENTS o Straight runs and gradual turns are based on tests with 0.1 static pressure. Amps 5.6 5.6 5.6 5.6 5.6 5.6 5.6...
...8226; VWH/DCH - 7" round duct • DWH - 3-1/4" x 10" round duct or equivalent o Never use flexible duct; Wall Hood w/Ventilator/ 12"H. Without applying static pressure (some brands do not), CFM could be greatly overstated. GAS Not applicable ELECTRICAL • Hardwire..." (25.4 cm) Interior Max. amp usage-5.6 PLUMBING Not applicable Note: All CFMs are best; Installation Requirements VENTILATION Built-In 10"H. Chimney Wall Hood w/Ventilator 6"H. UTILITY REQUIREMENTS o Straight runs and gradual turns are based on tests with 0.1 static pressure. Amps 5.6 5.6 5.6 5.6 5.6 5.6 5.6...
Specs
Page 7
...(WH), Almond (AL), Biscuit (BT), Stone Gray (SG), Graphite Gray (GG), Burgundy (BU), Lemonade (LE), Mint Julep (MJ), Forest Green (FG), Viking Blue (VB), Cobalt Blue (CB), and Eggplant (EP). duct cover Professional 36"W. ship wt. lbs. (kg) 9 (4.0) 10 (4.5) 11 (5.0) 20 (9.0) ... • 1-888-VIKING1 REVISED 5/2/11 © 2 0 1 1 V R C - VENTILATION Built-In 10"H. conversion kit Professional 36"W. conversion kit Designer 30"W. Designer hood filter for DCH 30" & 36" models Approx. lbs. (kg) 10 (4.5) 13 (5.9) 16 (7.3) 15.4 (7) 15.4 (7) Charcoal Filters • For use with VRK...
...(WH), Almond (AL), Biscuit (BT), Stone Gray (SG), Graphite Gray (GG), Burgundy (BU), Lemonade (LE), Mint Julep (MJ), Forest Green (FG), Viking Blue (VB), Cobalt Blue (CB), and Eggplant (EP). duct cover Professional 36"W. ship wt. lbs. (kg) 9 (4.0) 10 (4.5) 11 (5.0) 20 (9.0) ... • 1-888-VIKING1 REVISED 5/2/11 © 2 0 1 1 V R C - VENTILATION Built-In 10"H. conversion kit Professional 36"W. conversion kit Designer 30"W. Designer hood filter for DCH 30" & 36" models Approx. lbs. (kg) 10 (4.5) 13 (5.9) 16 (7.3) 15.4 (7) 15.4 (7) Charcoal Filters • For use with VRK...
Specs
Page 8
... Guide. warming shelf panel (one shelf) 36"W. backsplash 36"W. VENTILATION Built-In 10"H. x 28 - 40"H. • Extends height of hood by up /down, heavy-duty warming shelves (non-removable), factory installed on Viking products shipped within the United States and Canada. ship wt. INFORMATION SUBJECT TO CHANGE ship wt. Warranty valid on...
... Guide. warming shelf panel (one shelf) 36"W. backsplash 36"W. VENTILATION Built-In 10"H. x 28 - 40"H. • Extends height of hood by up /down, heavy-duty warming shelves (non-removable), factory installed on Viking products shipped within the United States and Canada. ship wt. INFORMATION SUBJECT TO CHANGE ship wt. Warranty valid on...
Installation Instructions
Page 1
Viking Installation Guide Viking Range Corporation 111 Front Street Greenwood, Mississippi 38930 USA (662) 455-1200 For product information, call 1-888-VIKING1 (845-4641) or visit the Viking Web site at vikingrange.com F20470G EN UL C UL (033111) Professional Hoods
Viking Installation Guide Viking Range Corporation 111 Front Street Greenwood, Mississippi 38930 USA (662) 455-1200 For product information, call 1-888-VIKING1 (845-4641) or visit the Viking Web site at vikingrange.com F20470G EN UL C UL (033111) Professional Hoods
Installation Instructions
Page 2
... DIV300, DIV440, DIV600, DIV800, DIV1200, VIV300, VIV600, or VIV1200. Wall Hoods w/Standard Ventilator 39 Installation (VWH 10"H. This hood is for residential installation only and is needed for blowers. Viking hoods are equipped with warming shelf panel, install warming shelf panel first. When cutting ...for future reference. • Check with a qualified and trained installer or local codes for local inspector's use with Viking Range hoods. All Viking ventilator kits are applicable, wire in accordance with the National Electrical Code, ANSI/NFPA 70-latest edition. • ...
... DIV300, DIV440, DIV600, DIV800, DIV1200, VIV300, VIV600, or VIV1200. Wall Hoods w/Standard Ventilator 39 Installation (VWH 10"H. This hood is for residential installation only and is needed for blowers. Viking hoods are equipped with warming shelf panel, install warming shelf panel first. When cutting ...for future reference. • Check with a qualified and trained installer or local codes for local inspector's use with Viking Range hoods. All Viking ventilator kits are applicable, wire in accordance with the National Electrical Code, ANSI/NFPA 70-latest edition. • ...
Installation Instructions
Page 3
...INJURY TO PERSONS Rangehoods must be installed with the ventilators that are specified on "Kitchen Firesafety Tips," published by NFPA.) 1. Wall Hoods w/Standard Ventilator Description 24" 30" 36" Duct cover width Duct cover depth Duct cover height Number of lights Number of a...suitability with your back to exhaust hazardous or explosive materials and vapors. You may be substituted. 4 Dimensions & Specifications (VWH 10"H. Wall Hoods w/Standard Ventilator 24", 30", & 36") (7.63"cm) A (Hood width) 24"W. 23-7/8" (60.6 cm) 30"W. 29-7/8" (76.2 cm) 36"W. 35-7/8" (91.1 cm) (301.25 " ...
...INJURY TO PERSONS Rangehoods must be installed with the ventilators that are specified on "Kitchen Firesafety Tips," published by NFPA.) 1. Wall Hoods w/Standard Ventilator Description 24" 30" 36" Duct cover width Duct cover depth Duct cover height Number of lights Number of a...suitability with your back to exhaust hazardous or explosive materials and vapors. You may be substituted. 4 Dimensions & Specifications (VWH 10"H. Wall Hoods w/Standard Ventilator 24", 30", & 36") (7.63"cm) A (Hood width) 24"W. 23-7/8" (60.6 cm) 30"W. 29-7/8" (76.2 cm) 36"W. 35-7/8" (91.1 cm) (301.25 " ...
Installation Instructions
Page 4
...) B C 4" (10.2 cm) A 18" (4.6 cm) D 3-4" (1.9 cm) 3-7/8" (9.8 cm) 7" (17.8 cm) dia. duct location 1/2" (1.3 cm) 3-1/2" (8.9 cm) Electrical hookup 460 CFM Interior Ventilator Installation 7 Clearance Dimensions (VWH 10"H. Wall Hoods w/Standard Ventilator) (913.46"cm) ((6611356020""t..mmo40 accinmmx..)) 22((766418""..mt06moaccimmxn..))* * NOTE: When installing with a 24" high-shelf, the 27" (68.6 cm) max. Wall...
...) B C 4" (10.2 cm) A 18" (4.6 cm) D 3-4" (1.9 cm) 3-7/8" (9.8 cm) 7" (17.8 cm) dia. duct location 1/2" (1.3 cm) 3-1/2" (8.9 cm) Electrical hookup 460 CFM Interior Ventilator Installation 7 Clearance Dimensions (VWH 10"H. Wall Hoods w/Standard Ventilator) (913.46"cm) ((6611356020""t..mmo40 accinmmx..)) 22((766418""..mt06moaccimmxn..))* * NOTE: When installing with a 24" high-shelf, the 27" (68.6 cm) max. Wall...
Installation Instructions
Page 5
... ((7611268672""t..mmo69 accinmmx..)) 33((796061""..t24mmoccaimmnx.)). 9 Dimensions & Specifications (VWH 18"H. 24" Deep Wall Hoods 24", 30", 36", 42", 48", 54", 60", & 66") (VWH 18"H. 27" Deep Wall Hoods 30", 36", 42", 48", 54", 60", & 66") A (Hood width) 24"W. 23-7/8" (60.6 cm) 30"W. 29-7/8" (76.2 cm) 36"W. 35-7/8" (91... (106.4 cm) 48"W. 47-7/8" (121.6 cm) 54"W. 53-7/8" (136.8 cm) 60"W. 59-7/8" (152.1 cm) 66"W. 65-7/8" (167.3 cm) (15.62"cm) B (Hood depth) 24"D. 24" (61.0 cm) A 27"D. 27" (68.6 cm) (301.52"cm) (451.78"cm) B NOTE: Optional duct cover sold separately. Max duct run is...
... ((7611268672""t..mmo69 accinmmx..)) 33((796061""..t24mmoccaimmnx.)). 9 Dimensions & Specifications (VWH 18"H. 24" Deep Wall Hoods 24", 30", 36", 42", 48", 54", 60", & 66") (VWH 18"H. 27" Deep Wall Hoods 30", 36", 42", 48", 54", 60", & 66") A (Hood width) 24"W. 23-7/8" (60.6 cm) 30"W. 29-7/8" (76.2 cm) 36"W. 35-7/8" (91... (106.4 cm) 48"W. 47-7/8" (121.6 cm) 54"W. 53-7/8" (136.8 cm) 60"W. 59-7/8" (152.1 cm) 66"W. 65-7/8" (167.3 cm) (15.62"cm) B (Hood depth) 24"D. 24" (61.0 cm) A 27"D. 27" (68.6 cm) (301.52"cm) (451.78"cm) B NOTE: Optional duct cover sold separately. Max duct run is...
Installation Instructions
Page 6
...(106.4 cm) 47-7/8" (121.6 cm) 53-7/8" (136.8 cm) 59-7/8" (152.1 cm) 65-7/8" (167.3 cm) 1200 or 1500 CFM Exterior Ventilator Installation for all Wall Hoods 11 Wall Hoods) 24"W. 30"W. 36"W. 42"W. 48"W. 54"W. 60"W. 66"W. B 23-7/8" (60.6 cm) 29-7/8" (75.9 cm) 35-7/8" (91.1 cm) 41-7/8" (106.4 cm)... cm) 47-7/8" (121.6 cm) 53-7/8" (136.8 cm) 59-7/8" (152.1 cm) 65-7/8" (167.3 cm) B 900 or 1200 CFM Exterior Ventilator Installation for all Wall Hoods Top View 5-15/16" (15.1 cm) A 8-3/16" (20.7 cm) 24"W. 30"W. 36"W. 42"W. 48"W. 54"W. 60"W. 66"W. Interior Ventilator Dimensions (VWH 18"H. ...
...(106.4 cm) 47-7/8" (121.6 cm) 53-7/8" (136.8 cm) 59-7/8" (152.1 cm) 65-7/8" (167.3 cm) 1200 or 1500 CFM Exterior Ventilator Installation for all Wall Hoods 11 Wall Hoods) 24"W. 30"W. 36"W. 42"W. 48"W. 54"W. 60"W. 66"W. B 23-7/8" (60.6 cm) 29-7/8" (75.9 cm) 35-7/8" (91.1 cm) 41-7/8" (106.4 cm)... cm) 47-7/8" (121.6 cm) 53-7/8" (136.8 cm) 59-7/8" (152.1 cm) 65-7/8" (167.3 cm) B 900 or 1200 CFM Exterior Ventilator Installation for all Wall Hoods Top View 5-15/16" (15.1 cm) A 8-3/16" (20.7 cm) 24"W. 30"W. 36"W. 42"W. 48"W. 54"W. 60"W. 66"W. Interior Ventilator Dimensions (VWH 18"H. ...
Installation Instructions
Page 7
... with all T-Series models and when indoor models are installed over range/rangetop with longer duct runs. Viking also recommends using a backsplash. 13 Max duct run is 75 ft. An interior- Dimensions & Specifications (VWH 18"H. VWH 18"H. T-Series Wall... Hoods 36", 48", & 60") Seal joints with ground. hoods. 12 Clearance Dimensions (VWH 18"H. The hood should be used with locally-supplied stainless steel. or exterior-power ventilator should be installed 4-1/2" (11.4...
... with all T-Series models and when indoor models are installed over range/rangetop with longer duct runs. Viking also recommends using a backsplash. 13 Max duct run is 75 ft. An interior- Dimensions & Specifications (VWH 18"H. VWH 18"H. T-Series Wall... Hoods 36", 48", & 60") Seal joints with ground. hoods. 12 Clearance Dimensions (VWH 18"H. The hood should be used with locally-supplied stainless steel. or exterior-power ventilator should be installed 4-1/2" (11.4...
Installation Instructions
Page 8
... is 75 ft. or exterior-power ventilator kit must be used when installed over range/rangetop with longer duct runs. Dimensions & Specifications (VCWH Chimney Wall Hoods 30", 36", 42", 48", 54", 60", & 66") A A (Duct width) 30"W. 12" (30.5 cm) 36"W. 12" (30.5 cm) 42"W. 12" (30.5 cm) 48"W. 18" (..."W. 59-7/8" (152.1 cm) B 66"W. 65-7/8" (167.3 cm) (612.04"cm) ((360112..t5024o""ccmm)) (451.78"cm) NOTE: Optional duct cover sold separately. VCWH Chimney Wall Hoods Description 30" 36" 42" 48" 54" 60" 66" Duct cover width 12" (30.5 cm) 12" (30.5 cm) 12" (30.5 cm) 18" (45.7 cm) 18...
... is 75 ft. or exterior-power ventilator kit must be used when installed over range/rangetop with longer duct runs. Dimensions & Specifications (VCWH Chimney Wall Hoods 30", 36", 42", 48", 54", 60", & 66") A A (Duct width) 30"W. 12" (30.5 cm) 36"W. 12" (30.5 cm) 42"W. 12" (30.5 cm) 48"W. 18" (..."W. 59-7/8" (152.1 cm) B 66"W. 65-7/8" (167.3 cm) (612.04"cm) ((360112..t5024o""ccmm)) (451.78"cm) NOTE: Optional duct cover sold separately. VCWH Chimney Wall Hoods Description 30" 36" 42" 48" 54" 60" 66" Duct cover width 12" (30.5 cm) 12" (30.5 cm) 12" (30.5 cm) 18" (45.7 cm) 18...
Installation Instructions
Page 9
.... duct location 1-1/2" (3.8 cm) B 300 or 600 CFM Interior Ventilator Installation for 48", 54", 60", & 66" models 16 Exterior Ventilator Dimensions (VCWH Chimney Wall Hoods) Top View 12" (30.5 cm) 1-1/2" (3.8 cm) A 120V power supply 30"W. 36"W. 42"W. 30"W. 36"W. 42"W. B 47-7/8" (121.6 cm) 53...15/16" (76.0 cm) 32-15/16" (83.7 cm) 6" (15.2 cm) 1-1/2" (3.8 cm) 48"W. 54"W. 60"W. 66"W. Interior Ventilator Dimensions (VCWH Chimney Wall Hoods) Top View 12" (30.5 cm) 1-1/2" (3.8 cm) A 120V power supply 30"W. 36"W. 42"W. 30"W. 36"W. 42"W. duct location B C 18" (45.7 cm) ...
.... duct location 1-1/2" (3.8 cm) B 300 or 600 CFM Interior Ventilator Installation for 48", 54", 60", & 66" models 16 Exterior Ventilator Dimensions (VCWH Chimney Wall Hoods) Top View 12" (30.5 cm) 1-1/2" (3.8 cm) A 120V power supply 30"W. 36"W. 42"W. 30"W. 36"W. 42"W. B 47-7/8" (121.6 cm) 53...15/16" (76.0 cm) 32-15/16" (83.7 cm) 6" (15.2 cm) 1-1/2" (3.8 cm) 48"W. 54"W. 60"W. 66"W. Interior Ventilator Dimensions (VCWH Chimney Wall Hoods) Top View 12" (30.5 cm) 1-1/2" (3.8 cm) A 120V power supply 30"W. 36"W. 42"W. 30"W. 36"W. 42"W. duct location B C 18" (45.7 cm) ...
Installation Instructions
Page 10
... with 2wire with gas char-grill. All products must be used when installed over range/rangetop with ground. Dimensions & Specifications (VIH Island Hoods 36", 42", 54", & 66") (15.62"cm) A (Hood width) 36"W. 35-7/8" (91.1 cm) 42"W. 41-7/8" (106.4 cm) 54"W. 53-7/8" (136.8 cm) 66"W. 65-7/8" (... Exterior ventilator kits In-line ventilator kits Interior duct size Exterior duct size Interior-Maximum amps Exterior-Maximum amps In-Line-Maximum amps VIH Island Hoods 36" 42" 54" 35-7/8" (91.1 cm) 41-7/8" (106.4 cm) 53-7/8" (136.8 cm) 12" (30.5 cm) 12" (30.5 cm) 4 4 6 4 4 6 VINV600/...
... with 2wire with gas char-grill. All products must be used when installed over range/rangetop with ground. Dimensions & Specifications (VIH Island Hoods 36", 42", 54", & 66") (15.62"cm) A (Hood width) 36"W. 35-7/8" (91.1 cm) 42"W. 41-7/8" (106.4 cm) 54"W. 53-7/8" (136.8 cm) 66"W. 65-7/8" (... Exterior ventilator kits In-line ventilator kits Interior duct size Exterior duct size Interior-Maximum amps Exterior-Maximum amps In-Line-Maximum amps VIH Island Hoods 36" 42" 54" 35-7/8" (91.1 cm) 41-7/8" (106.4 cm) 53-7/8" (136.8 cm) 12" (30.5 cm) 12" (30.5 cm) 4 4 6 4 4 6 VINV600/...
Installation Instructions
Page 11
... cm) 6-7/16" (16.4 cm) 120 V 3" (7.62 cm) 2-1/2" (6.35 cm) B 900 or 1200 CFM Exterior or In-Line Ventilator Installation for all Island Hoods Top View 36"W. 42"W. 54"W. 66"W. 36"W. 42"W. 54"W. 66"W. duct location 9-1/4" 9-1/2" (23.5 cm) (24.1 cm) 18-3/4" (47.6 cm) B ...15.1 cm) 9-3/4" (24.8 cm) 10" (25.4 cm) dia. duct location 9-1/8" (23.2 cm) 120 V 9-5/8" (24.4 cm) B 600 CFM Interior Ventilator Installation for all Island Hoods Top View A 36"W. 42"W. 54"W. 66"W. 36"W. 42"W. 54"W. 66"W. duct location A 8-3/16" (20.7 cm) 6-5/8" (6.35 cm) 120 3" (7.62 cm) V 2-1/2" (6....
... cm) 6-7/16" (16.4 cm) 120 V 3" (7.62 cm) 2-1/2" (6.35 cm) B 900 or 1200 CFM Exterior or In-Line Ventilator Installation for all Island Hoods Top View 36"W. 42"W. 54"W. 66"W. 36"W. 42"W. 54"W. 66"W. duct location 9-1/4" 9-1/2" (23.5 cm) (24.1 cm) 18-3/4" (47.6 cm) B ...15.1 cm) 9-3/4" (24.8 cm) 10" (25.4 cm) dia. duct location 9-1/8" (23.2 cm) 120 V 9-5/8" (24.4 cm) B 600 CFM Interior Ventilator Installation for all Island Hoods Top View A 36"W. 42"W. 54"W. 66"W. 36"W. 42"W. 54"W. 66"W. duct location A 8-3/16" (20.7 cm) 6-5/8" (6.35 cm) 120 3" (7.62 cm) V 2-1/2" (6....
Installation Instructions
Page 12
... cm) 24" (70.0 cm) B (Duct height) 36"W. 42"W. 54"W. 66"W. 12" (30.5 cm) or 24" (61.0 cm) or 36" (91.4 cm) (15.62"cm) C (Hood width) 36"W. 35-7/8" (91.1 cm) C 42"W. 41-7/8" (106.4 cm) 54"W. 53-7/8" (136.8 cm) 66"W. 65-7/8" (167.3 cm) (763.20"cm) B (451.78"cm) NOTE: ... cover sold separately. Max duct run is 50 ft. ** It is 75 ft. All products must be used with ground. VCIH Chimney Island Hoods Description Duct cover width Duct cover depth Duct cover height Number of lights Number of filters Heat lamps Interior ventilator kits Exterior ventilator kits In...
... cm) 24" (70.0 cm) B (Duct height) 36"W. 42"W. 54"W. 66"W. 12" (30.5 cm) or 24" (61.0 cm) or 36" (91.4 cm) (15.62"cm) C (Hood width) 36"W. 35-7/8" (91.1 cm) C 42"W. 41-7/8" (106.4 cm) 54"W. 53-7/8" (136.8 cm) 66"W. 65-7/8" (167.3 cm) (763.20"cm) B (451.78"cm) NOTE: ... cover sold separately. Max duct run is 50 ft. ** It is 75 ft. All products must be used with ground. VCIH Chimney Island Hoods Description Duct cover width Duct cover depth Duct cover height Number of lights Number of filters Heat lamps Interior ventilator kits Exterior ventilator kits In...