Ventilation Products
Page 14
VIPR102R 36" width - VIPR162 48" width - VIPR182R VIPR102 36" width - VIPR182 MODELS WITH REMOTEMOUNTED CONTROLS 30" width - VIPR162R 48" width - VersaVentTM rear downdrafts Retractable downdrafts quietly do their job, then disappear into your countertop. 14 MODELS WITH CONTROLS ON DOWNDRAFT 30" width -
VIPR102R 36" width - VIPR162 48" width - VIPR182R VIPR102 36" width - VIPR182 MODELS WITH REMOTEMOUNTED CONTROLS 30" width - VIPR162R 48" width - VersaVentTM rear downdrafts Retractable downdrafts quietly do their job, then disappear into your countertop. 14 MODELS WITH CONTROLS ON DOWNDRAFT 30" width -
Ventilation Products
Page 15
...top or with a separate remote-mounted control which can be used when downdraft is installed with Viking rangetops Must use Viking ventilator kits with Viking downdrafts; Appearance and design For use with Viking Professional rangetops (non-grill models only) and cooktops Suitable for island ...and wall installations Downdraft raises and lowers at the touch of a button • When ...
...top or with a separate remote-mounted control which can be used when downdraft is installed with Viking rangetops Must use Viking ventilator kits with Viking downdrafts; Appearance and design For use with Viking Professional rangetops (non-grill models only) and cooktops Suitable for island ...and wall installations Downdraft raises and lowers at the touch of a button • When ...
Ventilation Products
Page 28
VersaVentTM rear downdrafts 30" width - DIPR161R 45" width - DIPR101R 36" width - DIPR151R Remote-mounted control panels install anywhere on your countertop. 28
VersaVentTM rear downdrafts 30" width - DIPR161R 45" width - DIPR101R 36" width - DIPR151R Remote-mounted control panels install anywhere on your countertop. 28
Ventilation Products
Page 29
...minutes before automatically shutting off feature allows operation for use with 45" wide downdraft only) Stainless steel finish is right on countertop and allows user to operate downdraft without having to reach over cooking surface/vessels Downdraft raises and lowers at the touch of a button • When not in... to clean filters after approximately 30 hours of use Must use of it. 29 Appearance and design For use with Viking Designer rangetops and cooktops Suitable for both island and wall installations Available with remote-mounted control only • Installs on top of...
...minutes before automatically shutting off feature allows operation for use with 45" wide downdraft only) Stainless steel finish is right on countertop and allows user to operate downdraft without having to reach over cooking surface/vessels Downdraft raises and lowers at the touch of a button • When not in... to clean filters after approximately 30 hours of use Must use of it. 29 Appearance and design For use with Viking Designer rangetops and cooktops Suitable for both island and wall installations Available with remote-mounted control only • Installs on top of...
Ventilation Products
Page 31
... with Ledge, Classic Chimney Ledgeless, and Slim Traditional hoods only Extend height of island hoods (CR4 or BR4) Replacement Remote-Mounted Control Available for Designer downdraft Gray with kit) attach to clean 30" (BKS30), 36" (BKS36), 42" (BKS42), and 48" (BKS48) widths; 30" high Available in Stainless Steel (SS) only Accessory...
... with Ledge, Classic Chimney Ledgeless, and Slim Traditional hoods only Extend height of island hoods (CR4 or BR4) Replacement Remote-Mounted Control Available for Designer downdraft Gray with kit) attach to clean 30" (BKS30), 36" (BKS36), 42" (BKS42), and 48" (BKS48) widths; 30" high Available in Stainless Steel (SS) only Accessory...
Ventilation Products
Page 32
...kitchens and truly consistent design, while delivering the quality and performance that makes Viking the true market leader. No matter the look you're going for maintenance-free normal use Rear downdrafts available in Stainless Steel (SS) Convection microwave hoods available in form and...CH), and Cobalt Blue (CB) For brass trim, order Accessory Rail in both performance and design should be noticed because of three Viking product offerings - Design integrity Exclusive finishes Consistency in brass (all Professional hoods and Designer classic chimney wall and island hoods only); ...
...kitchens and truly consistent design, while delivering the quality and performance that makes Viking the true market leader. No matter the look you're going for maintenance-free normal use Rear downdrafts available in Stainless Steel (SS) Convection microwave hoods available in form and...CH), and Cobalt Blue (CB) For brass trim, order Accessory Rail in both performance and design should be noticed because of three Viking product offerings - Design integrity Exclusive finishes Consistency in brass (all Professional hoods and Designer classic chimney wall and island hoods only); ...
Ventilation Products
Page 33
...-year full - Warranty highlights Professional and Designer Series wall and island hoods, Professional downdraft Three-year full - cosmetic parts such as glass, painted items, and decorative items mint julep sea glass iridescent blue viking blue pumpkin racing red apple red burgundy plum black chocolate cobalt blue 33 all ventilator motors Ninety-day...
...-year full - Warranty highlights Professional and Designer Series wall and island hoods, Professional downdraft Three-year full - cosmetic parts such as glass, painted items, and decorative items mint julep sea glass iridescent blue viking blue pumpkin racing red apple red burgundy plum black chocolate cobalt blue 33 all ventilator motors Ninety-day...
Ventilation Products
Page 41
DIPR101RSS 36" W. Rear downdrafts - VIPR162(R)SS 48" W. VIPR182(R)SS Number of Filters 2 2 2 re a r d o wndr a f t s Recommended Ventilator Kits Recommended Duct Size Interior VIDV500 VIDV500 VIDV500 Exterior VEDV900/VEDV1200 VEDV900/VEDV1200 ... Interior 10" (can transition to 6" round) 10" (can transition to 6" round) 10" (can transition to 6" round) Exterior 10" 10" 10" Maximum Amps Interior 4.0 Exterior 6.0 4.0 6.0 4.0 6.0 Rear downdrafts - Professional Model 30" W. DIPR161RSS 45" W.
DIPR101RSS 36" W. Rear downdrafts - VIPR162(R)SS 48" W. VIPR182(R)SS Number of Filters 2 2 2 re a r d o wndr a f t s Recommended Ventilator Kits Recommended Duct Size Interior VIDV500 VIDV500 VIDV500 Exterior VEDV900/VEDV1200 VEDV900/VEDV1200 ... Interior 10" (can transition to 6" round) 10" (can transition to 6" round) 10" (can transition to 6" round) Exterior 10" 10" 10" Maximum Amps Interior 4.0 Exterior 6.0 4.0 6.0 4.0 6.0 Rear downdrafts - Professional Model 30" W. DIPR161RSS 45" W.
Specs
Page 1
... Notes & Accessories) • Filter alert (flashing light) reminds you to clean filters after approx. 30 hours of a Viking gas char-grill or wok, a Viking 18"H. VENTILATION Built-In VersaVent™ Rear Downdraft Standard Features & Accessories All models include • Downdraft blower systems are dishwasher-safe and sized VIPR models include • For use with...
... Notes & Accessories) • Filter alert (flashing light) reminds you to clean filters after approx. 30 hours of a Viking gas char-grill or wok, a Viking 18"H. VENTILATION Built-In VersaVent™ Rear Downdraft Standard Features & Accessories All models include • Downdraft blower systems are dishwasher-safe and sized VIPR models include • For use with...
Specs
Page 2
VENTILATION Built-In VersaVent™ Rear Downdraft % Please see Installation Notes & Accessories for important information, including blower kits and remote mounted controls. ship. wt. 43 lbs. (....COM • 1-888-VIKING1 REVISED 5/2/11 © 2 0 1 1 V R C - INFORMATION SUBJECT TO CHANGE Dimensions & Specifications PRODUCT DIMENSIONS VIPR Professional Downdraft VIPR Professional Downdraft w/Remote DIPR Designer Downdraft w/Remote (5.12"cm) A PROFESSIONAL (5.12"cm) A 8(2-121.1/1cm6") DESIGNER (82-01.5/1c6m") VIPR102/102R Overall width (A) 30" (76.2 cm) Overall...
VENTILATION Built-In VersaVent™ Rear Downdraft % Please see Installation Notes & Accessories for important information, including blower kits and remote mounted controls. ship. wt. 43 lbs. (....COM • 1-888-VIKING1 REVISED 5/2/11 © 2 0 1 1 V R C - INFORMATION SUBJECT TO CHANGE Dimensions & Specifications PRODUCT DIMENSIONS VIPR Professional Downdraft VIPR Professional Downdraft w/Remote DIPR Designer Downdraft w/Remote (5.12"cm) A PROFESSIONAL (5.12"cm) A 8(2-121.1/1cm6") DESIGNER (82-01.5/1c6m") VIPR102/102R Overall width (A) 30" (76.2 cm) Overall...
Specs
Page 3
... W/REMOTE (10.2 4" cm) FILTER 1 2 3 4 DOWUNP (0.161c/m16)(0"to.081c/m32) " Note: Accurate alignment of cooktop and downdraft is necessary to ensure that oversized cabinets be 4" min. For ducting clearance, check location of floor joists, wall studs, electrical wiring or plumbing... enough flat space. Dimensions & Specifications CLEARANCE DIMENSIONS VENTILATION Built-In VersaVent™ Rear Downdraft 1-3/4" (4.4 cm) 2" (5.1 cm) Countertop Cooktop Downdraft Front to back inside back of cabinet. (Viking recommends that there is no interference when air vent is raised and lowered.
... W/REMOTE (10.2 4" cm) FILTER 1 2 3 4 DOWUNP (0.161c/m16)(0"to.081c/m32) " Note: Accurate alignment of cooktop and downdraft is necessary to ensure that oversized cabinets be 4" min. For ducting clearance, check location of floor joists, wall studs, electrical wiring or plumbing... enough flat space. Dimensions & Specifications CLEARANCE DIMENSIONS VENTILATION Built-In VersaVent™ Rear Downdraft 1-3/4" (4.4 cm) 2" (5.1 cm) Countertop Cooktop Downdraft Front to back inside back of cabinet. (Viking recommends that there is no interference when air vent is raised and lowered.
Specs
Page 4
... turns are best; GAS • Not applicable ELECTRICAL • 2'-long power cord with ground, using locally-supplied wire, and connected to the downdraft plug (included) • 120 VAC/60 Hz • Max. Use a qualified and trained installer. for makeup air requirements, if any.... a minimum number of elbows. • The system will operate most efficiently when the ductwork does not exceed 40' of equivalent duct. VIPR Professional Downdraft w/Remote UTILITY REQUIREMENTS o 6" or 10" round elbow= 6' of straight duct o 3-1/4" x 10" to ensure maximum performance. PLANNING AND DESIGN ...
... turns are best; GAS • Not applicable ELECTRICAL • 2'-long power cord with ground, using locally-supplied wire, and connected to the downdraft plug (included) • 120 VAC/60 Hz • Max. Use a qualified and trained installer. for makeup air requirements, if any.... a minimum number of elbows. • The system will operate most efficiently when the ductwork does not exceed 40' of equivalent duct. VIPR Professional Downdraft w/Remote UTILITY REQUIREMENTS o 6" or 10" round elbow= 6' of straight duct o 3-1/4" x 10" to ensure maximum performance. PLANNING AND DESIGN ...
Specs
Page 5
...© 2 0 1 1 V R C - VENTILATION Built-In VersaVent™ Rear Downdraft Installation Requirements PROFESSIONAL ACCESS REQUIREMENTS & SITE PREPARATION 7/8" (2.2 cm) 27" (68.6 cm) 7/8" (2.2 cm) 2-1/4" (5.7 cm) Downdraft: VIPR101/101R 20-1/4" Cooktop: VECU106 (51.4 cm) 28-3/4" (73.0 cm) VIPR102/102R..." (76.2 cm) 33" (83.8 cm) 1-1/4" (3.2 cm) 1-1/2" (3.8 cm) 3" (7.6 cm) Downdraft: VIPR161/161R Cooktop: VGSU163 18-3/4" (47.6 cm) 33" (83.8 cm) 1-1/2" (3.8 cm) 2-3/4" (7.0 cm) Downdraft: VIPR161R Rangetop: VGRT536 24" (61.0 cm) 34-3/4" (88.3 cm) VIPR162/162R 1-1/2" (3.8 cm) ...
...© 2 0 1 1 V R C - VENTILATION Built-In VersaVent™ Rear Downdraft Installation Requirements PROFESSIONAL ACCESS REQUIREMENTS & SITE PREPARATION 7/8" (2.2 cm) 27" (68.6 cm) 7/8" (2.2 cm) 2-1/4" (5.7 cm) Downdraft: VIPR101/101R 20-1/4" Cooktop: VECU106 (51.4 cm) 28-3/4" (73.0 cm) VIPR102/102R..." (76.2 cm) 33" (83.8 cm) 1-1/4" (3.2 cm) 1-1/2" (3.8 cm) 3" (7.6 cm) Downdraft: VIPR161/161R Cooktop: VGSU163 18-3/4" (47.6 cm) 33" (83.8 cm) 1-1/2" (3.8 cm) 2-3/4" (7.0 cm) Downdraft: VIPR161R Rangetop: VGRT536 24" (61.0 cm) 34-3/4" (88.3 cm) VIPR162/162R 1-1/2" (3.8 cm) ...
Specs
Page 6
...20-5/8" (52.4 cm) 29-1/8" (73.9 cm) DIPR101R 7/16" (1.1 cm) 42" (106.7 cm) 7/16" (1.1 cm) 2-1/4" (5.7 cm) Downdraft: DIPR150R Cooktops: DECU155 or DGCU155 20-5/8" (52.4 cm) DIPR151R 42-7/8" (108.9 cm) 34-7/8" (88.6 cm) DIPR161R TOP EDGE 1/4" (0.6 cm) ...DIA. HOLE CUT OUT ON DOTTED LINE REMOTE CONTROL CUTOUT Model DIPR101R w/DECU105 w/DGCU105 w/DGSU100 DIPR161R w/DECU165 w/DGCU165 w/DGSU160 DIPR151R w/DECU155 w/DGCU155 Downdraft Cutout Width Depth 27" (68.6 cm) 27" (68.6 cm) 27" (68.6 cm) 2-1/4" (5.7 cm) 2-1/4" (5.7 cm) 2-1/4" (5.7 cm) 33" (83.8 cm)...
...20-5/8" (52.4 cm) 29-1/8" (73.9 cm) DIPR101R 7/16" (1.1 cm) 42" (106.7 cm) 7/16" (1.1 cm) 2-1/4" (5.7 cm) Downdraft: DIPR150R Cooktops: DECU155 or DGCU155 20-5/8" (52.4 cm) DIPR151R 42-7/8" (108.9 cm) 34-7/8" (88.6 cm) DIPR161R TOP EDGE 1/4" (0.6 cm) ...DIA. HOLE CUT OUT ON DOTTED LINE REMOTE CONTROL CUTOUT Model DIPR101R w/DECU105 w/DGCU105 w/DGSU100 DIPR161R w/DECU165 w/DGCU165 w/DGSU160 DIPR151R w/DECU155 w/DGCU155 Downdraft Cutout Width Depth 27" (68.6 cm) 27" (68.6 cm) 27" (68.6 cm) 2-1/4" (5.7 cm) 2-1/4" (5.7 cm) 2-1/4" (5.7 cm) 33" (83.8 cm)...
Specs
Page 7
... Approx. ship wt. Without applying static pressure (some brands do not), CFM could be greatly overstated Model VEDV900 VEDV1200 Description 900 CFM downdraft blower 1200 CFM downdraft blower Max. from burners • 4"W. lbs. (kg) 1.5 (0.7) Compliance Information WARRANTY SUMMARY* • Three-year full warranty-complete.../181R Note: Exhaust capacity based on wall or roof (no roof cap required) • Comes with Viking downdrafts; INFORMATION SUBJECT TO CHANGE Without applying static pressure (some brands do not), CFM could be greatly overstated Model VIDV500 Description ...
... Approx. ship wt. Without applying static pressure (some brands do not), CFM could be greatly overstated Model VEDV900 VEDV1200 Description 900 CFM downdraft blower 1200 CFM downdraft blower Max. from burners • 4"W. lbs. (kg) 1.5 (0.7) Compliance Information WARRANTY SUMMARY* • Three-year full warranty-complete.../181R Note: Exhaust capacity based on wall or roof (no roof cap required) • Comes with Viking downdrafts; INFORMATION SUBJECT TO CHANGE Without applying static pressure (some brands do not), CFM could be greatly overstated Model VIDV500 Description ...
Installation Instructions
Page 1
...may ignite. Follow the heating equipment manufacturer's guideline and safety standards such as those published by reaching across burners, an "R" model downdraft (with remote control) MUST be locked, securely fasten a prominent warning device, such as a tag, to accumulate on accidentally.When... ! TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE: a) Never leave surface units unattended at least 4" from being called. VIKING RANGE CORPORATION Downdraft Ventilators MODEL VIPR102 VIPR102R VIPR162 VIPR162R VIPR182 VIPR182R WIDTH 30" 30" w/ remote control 36" 36" w/ remote control 48" 48" ...
...may ignite. Follow the heating equipment manufacturer's guideline and safety standards such as those published by reaching across burners, an "R" model downdraft (with remote control) MUST be locked, securely fasten a prominent warning device, such as a tag, to accumulate on accidentally.When... ! TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE: a) Never leave surface units unattended at least 4" from being called. VIKING RANGE CORPORATION Downdraft Ventilators MODEL VIPR102 VIPR102R VIPR162 VIPR162R VIPR182 VIPR182R WIDTH 30" 30" w/ remote control 36" 36" w/ remote control 48" 48" ...
Installation Instructions
Page 2
... 3-1/4" X 10" DUCT CONNECTOR ELECTRICAL SPECIFICATIONS 120 VAC • 60 Hz • 4.0 A TAKE MEASUREMENTS Exterior Blower Installation This downdraft blower system is necessary between the back edge of the cooktop and the inside of cabinet back. 2 Note that 2" of flat ...the areas of potential interference highlighted above. A countertop with a variety of gas or electric cooktops. VIKING RANGE CORPORATION Downdraft Ventilators PLANNING Interior Blower Installation This downdraft blower system is NORMAL and will cause no harm, but can be corrected by lowering the speed of...
... 3-1/4" X 10" DUCT CONNECTOR ELECTRICAL SPECIFICATIONS 120 VAC • 60 Hz • 4.0 A TAKE MEASUREMENTS Exterior Blower Installation This downdraft blower system is necessary between the back edge of the cooktop and the inside of cabinet back. 2 Note that 2" of flat ...the areas of potential interference highlighted above. A countertop with a variety of gas or electric cooktops. VIKING RANGE CORPORATION Downdraft Ventilators PLANNING Interior Blower Installation This downdraft blower system is NORMAL and will cause no harm, but can be corrected by lowering the speed of...
Installation Instructions
Page 3
...has the shortest length of ductwork and a minimum number of elbows and transitions. The exterior downdraft blower system is designed for accurate alignment of floor joists, wall studs, electrical wiring or ...designed for possible interference. 6" ROUND ELBOW 3-1/4" X 10" TO 6" RD. Check location of ductwork. OF STRAIGHT DUCT 3. VIKING RANGE CORPORATION TAKE MEASUREMENTS (CONTINUED) Downdraft Ventilators Interior Blower Installation SIDE VIEW OF DOWNDRAFT WITH VIDV500 INTERIOR BLOWER 2" 7 11 16 " 1" 3 1 4 " 3 5 8 " 18" 5" VVIIDV550000 ININTTEERRNIOARL BBLLOOWWEERR...
...has the shortest length of ductwork and a minimum number of elbows and transitions. The exterior downdraft blower system is designed for accurate alignment of floor joists, wall studs, electrical wiring or ...designed for possible interference. 6" ROUND ELBOW 3-1/4" X 10" TO 6" RD. Check location of ductwork. OF STRAIGHT DUCT 3. VIKING RANGE CORPORATION TAKE MEASUREMENTS (CONTINUED) Downdraft Ventilators Interior Blower Installation SIDE VIEW OF DOWNDRAFT WITH VIDV500 INTERIOR BLOWER 2" 7 11 16 " 1" 3 1 4 " 3 5 8 " 18" 5" VVIIDV550000 ININTTEERRNIOARL BBLLOOWWEERR...
Installation Instructions
Page 4
...;" x 3½" CUTOUT (TYP.) 1" to 8" 5½" CENTER LINE OF COUNTER CUTOUT 3½" 2¾" CENTER LINE OF DUCT CUTOUT 10" ROUND DIA. VIKING RANGE CORPORATION PLAN THE CABINET CUTOUTS Interior Blower Installation Downdraft Ventilators Exterior Blower Installation LEFT SIDE DISCHARGE LEFT SIDE DISCHARGE CENTER LINES OF DUCT CUTOUT 10¼" x 3½" CUTOUT (TYP.) RIGHT...
...;" x 3½" CUTOUT (TYP.) 1" to 8" 5½" CENTER LINE OF COUNTER CUTOUT 3½" 2¾" CENTER LINE OF DUCT CUTOUT 10" ROUND DIA. VIKING RANGE CORPORATION PLAN THE CABINET CUTOUTS Interior Blower Installation Downdraft Ventilators Exterior Blower Installation LEFT SIDE DISCHARGE LEFT SIDE DISCHARGE CENTER LINES OF DUCT CUTOUT 10¼" x 3½" CUTOUT (TYP.) RIGHT...
Installation Instructions
Page 5
VIKING RANGE CORPORATION Downdraft Ventilators PLAN THE WIRING Interior Blower Installation 1. The downdraft has a 2 ft. Plan to provide a grounded outlet in the back wall of flat work surface. 2. IMPORTANT - PREPARE THE DOWNDRAFT Interior Blower Installation Exterior Blower Installation 1. The Exterior Downdraft Blower system draws 6...the cabinet. Then provide a clearance hole in a 48" wide cabinet... ...the outlet cannot be covered by the downdraft. The downdraft has a 2 ft. IMPORTANT - or Models VIPR162SS or VIPR162RSS are being installed in a 30" wide cabinet... or...
VIKING RANGE CORPORATION Downdraft Ventilators PLAN THE WIRING Interior Blower Installation 1. The downdraft has a 2 ft. Plan to provide a grounded outlet in the back wall of flat work surface. 2. IMPORTANT - PREPARE THE DOWNDRAFT Interior Blower Installation Exterior Blower Installation 1. The Exterior Downdraft Blower system draws 6...the cabinet. Then provide a clearance hole in a 48" wide cabinet... ...the outlet cannot be covered by the downdraft. The downdraft has a 2 ft. IMPORTANT - or Models VIPR162SS or VIPR162RSS are being installed in a 30" wide cabinet... or...